--***************************************************************** -- ADC-FLEXWAVE-URH.mib : MIB file name -- -- Copyright (c) 2007, 2008, 2009, 2010 by ADC Telecommunications, Inc. -- Copyright (c) 2011, 2012 by TE Connectivity. -- All rights reserved. -- --***************************************************************** ADC-FLEXWAVE-URH-MIB DEFINITIONS ::= BEGIN IMPORTS DateAndTime, TEXTUAL-CONVENTION, DisplayString, RowStatus FROM SNMPv2-TC enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, IpAddress, TimeTicks, Integer32, Unsigned32, Counter32, Counter64, OBJECT-IDENTITY FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF ALARMType, BANDType, LNAType, DuplexerType, OPTICSType, MODEType, CONTACTType, GAINType, DELAYType, ALARMManage,MODULEType, ENETType, CATALOGType, RauBandType, UnitID2, UnitID3, UnitType, ALARMEnable FROM ADC-FWU-URH-TC-MIB; flexwaveURHMibModule MODULE-IDENTITY LAST-UPDATED "201210030000Z" ORGANIZATION "TE Connectivity" CONTACT-INFO "PHONE U.S.A. or CANADA: Sales: 1-800-366-3891 Extn: 73000 Technical Assistance: 1-800-530-9960 Connectivity Extn: 73475 Wireless Extn: 73476 EUROPE: Sales Administration: +32-2-712-65 00 Technical Assistance: +32-2-712-65 42 EUROPEAN TOLL FREE NUMBERS: Germany: 0180 2232923 UK: 0800 960236 Spain: 900 983291 France: 0800 914032 Italy: 0800 782374 ASIA/PACIFIC: Sales Administration: +65-6294-9948 Technical Assistance: +65-6393-0739 ELSEWHERE: Sales Administration: +1-952-917-3000 Technical Assistance: +1-952-917-3475 EMAIL: Connectivity Products United States: Connectivity.Tac@te.com Europe: Euro.Tac@te.com Asia/Pacific: AsiaPacific.Tac@te.com All Wireless Products: WirelessSupport@te.com ONLINE ACCESS: Customer Portal: http://www.adc.com/Americas/en_US/1268116693520 Online Customer Support Request: https://nssales.adc.com/ftr/ftrhome1.asp" DESCRIPTION "This is the MIB for managing entities associated with FlexWave Prism & InterReach SPECTRUM products for SW Version 8.1" REVISION "201210030000Z" DESCRIPTION "Commenting HstLinkingMode as deprecated." REVISION "201208240000Z" DESCRIPTION "This is for SW Version 8.0. Noted relationships among objects in the descriptions." ::= { flexwaveurh 1 } -- .1.3.6.1.4.1.2014 adc OBJECT IDENTIFIER ::= { enterprises 2014 } flexwave OBJECT IDENTIFIER ::= { adc 15 } flexwaveurh OBJECT IDENTIFIER ::= { flexwave 2 } -- 15.2.1.3 fwuGeneralObjects OBJECT IDENTIFIER ::= { flexwaveURHMibModule 3 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Notification Objects (.15.2.1.3.1) -- -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuNotifObjects OBJECT IDENTIFIER ::= { fwuGeneralObjects 1 } fwuTrapSequenceNumber OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Count of the total number of traps (including this trap), raised by the agent." ::= { fwuNotifObjects 1 } fwuTrapTimeStamp OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The trap time stamp." ::= { fwuNotifObjects 2 } fwuNotificationStatus OBJECT-TYPE SYNTAX ALARMType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The severity of the fault." ::= { fwuNotifObjects 3 } fwuModuleType OBJECT-TYPE SYNTAX MODULEType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The module type reporting alarm." ::= { fwuNotifObjects 4 } fwuModuleNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The numerical Id of module, for the above module type, reporting the alarm." ::= { fwuNotifObjects 5 } fwuTrapCode OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The unique ID of the trap." ::= { fwuNotifObjects 6 } fwuTrapNodeAddress OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Unit from which the trap originated." ::= { fwuNotifObjects 7 } fwuAlarmedModuleName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Name of the hardware module where the trap originated." ::= { fwuNotifObjects 8 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Host Unit Objects; -- OID: 15.2.1.1 -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuHostUnitObjects OBJECT IDENTIFIER ::= { flexwaveURHMibModule 1 } fwuHstSystemLevelObjects OBJECT IDENTIFIER ::= { fwuHostUnitObjects 1 } fwuHstSystemLevelInfo OBJECT IDENTIFIER ::= { fwuHstSystemLevelObjects 1 } fwuHstGeneral OBJECT IDENTIFIER ::= { fwuHstSystemLevelInfo 1 } -- .1.1.1.1 fwuHstNumber OBJECT-TYPE SYNTAX INTEGER (1) MAX-ACCESS read-only STATUS current DESCRIPTION "Host Number." DEFVAL { 1 } ::= { fwuHstGeneral 1 } -- .1.1.1.2 fwuHstName OBJECT-TYPE SYNTAX DisplayString (SIZE(0 .. 64)) MAX-ACCESS read-write STATUS current DESCRIPTION "User defined name of the host unit. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters." DEFVAL { "Host" } ::= { fwuHstGeneral 2 } -- .1.1.1.3 fwuHstUnitReset OBJECT-TYPE SYNTAX INTEGER { normal(0), reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Use to reset the Host. Do this by changing from normal(0) to reset(1). After the operation has completed the state automatically changes to normal." DEFVAL { 0 } ::= { fwuHstGeneral 3 } -- .1.1.1.4 fwuHstBackPlaneRev OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The back plane revision of the Host (It is the three pin version number of the chassis back plane)." ::= { fwuHstGeneral 4 } -- .1.1.1.5 fwuHstAlarmStatusSummary OBJECT-TYPE SYNTAX ALARMType MAX-ACCESS read-only STATUS current DESCRIPTION "Summary of alarm status on the Host." ::= { fwuHstGeneral 5 } -- .1.1.1.6 fwuHstTempMeas OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host system temperature value in Celsius." ::= { fwuHstGeneral 6 } -- .1.1.1.7 fwuSystemAlarmStatusSummary OBJECT-TYPE SYNTAX ALARMType MAX-ACCESS read-only STATUS current DESCRIPTION "Summary of alarm status on the System. If there a unit in the system (Host and all remotes) with a fault condition, it will be reflected here. Severity is summarised by the highest severity of the alarms in the system. i.e. If there is at least one Major alarm, the summary will indicate Major Alarm. The severities supported are Major, Minor and OK." ::= { fwuHstGeneral 7 } -- .1.1.1.8 --fwuHstLinkingMode OBJECT-TYPE -- SYNTAX INTEGER { automated(1), manual(2)} -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION "The DART Linking mode of the system. Only the automated mode is supported. The manual mode is obsolete. " -- DEFVAL { 1 } -- ::= { fwuHstGeneral 8 } fwuHstSystemDateAndTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0 .. 20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Date and Time settings on the system." ::= { fwuHstGeneral 9 } fwuAlarmAck OBJECT-TYPE SYNTAX INTEGER { acknowledgeAll(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to acknowledgement one or all alarms in the system. Set 0 to acknowledge all alarms or the alarm code (numeric ID) of the alarm to be acknowledged. This is a integer greater than 0." DEFVAL { 0 } ::= { fwuHstGeneral 11 } fwuAlarmLevel OBJECT-TYPE SYNTAX ALARMType MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm status summary of system." DEFVAL { 1 } ::= { fwuHstGeneral 12 } fwuUserCommLinkTest OBJECT-TYPE SYNTAX INTEGER { inactive(0), start(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to perform the system test manually. Set the value to 1 to initiate the test. Once started, the test cannot be cancelled. User has to wait for completion. On completion of the test, the value reverts back to 0. Use fwuUserCommLinkTestDartBandType or fwuUserCommLinkTestDartId to provide parameters for the test." DEFVAL { 0 } ::= { fwuHstGeneral 13 } fwuUserLinkTestStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Provides the status of the System/Link test, once the test has started. Start the test using fwuUserCommLinkTest. Status is reported in the format X;Y where X is the test status (number) and Y is the unit number. The valid values of the test status and their associated meaning. (0) - Test has not started. This is the default value. (1) - Test started. (2,3,4,5,6,7,8,9,10,11,12,13,14) - Test is in progress. (15) - Test completed. (16) - Test Failed." DEFVAL { "0" } ::= { fwuHstGeneral 14 } fwuUserCommLinkTestDartBandType OBJECT-TYPE SYNTAX BANDType MAX-ACCESS read-write STATUS current DESCRIPTION "Bands on which the system test is to be run. Refer TC BANDType for list. 0 to select all provisioned bands for the test. If a non-zero value is provided here then fwuUserCommLinkTestDartId must be empty. If zero is provided here then fwuUserCommLinkTestDartId may be set to 0 or empty. " DEFVAL { -1 } ::= { fwuHstGeneral 15 } fwuUserCommLinkTestDartId OBJECT-TYPE SYNTAX Integer32(0 .. 8) MAX-ACCESS read-write STATUS current DESCRIPTION "Identify the DARTs on which the system test is to be run. It is the DART slot number on Host unit. Use 0 to select all provisioned DARTs for the test. Other valid values are 1 to 8 and -1. If a non-zero value is provided here then fwuUserCommLinkTestDartBandType must be empty. If zero is provided here then fwuUserCommLinkTestDartBandType may be set to 0 or empty. " DEFVAL { 0 } ::= { fwuHstGeneral 16 } fwuClearSysConfig OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} MAX-ACCESS read-write STATUS current DESCRIPTION "To Clear System Configuration. Change the value from 0 to 1 to clear all the settings on the system. Also, known as Restore To Factory Defaults (RTFD)." DEFVAL { 0 } ::= { fwuHstGeneral 17 } --fwuPwrUpLinkTest OBJECT-TYPE -- SYNTAX INTEGER { disable(0), enable(1) } -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION "System/Link Test on Power Up. (Link Test)." -- DEFVAL { 0 } -- ::= { fwuHstGeneral 18 } fwuLinkTestLastRuntime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Time indicating the most recent execution of System/Link Test." ::= { fwuHstGeneral 19 } fwuNTPServerIP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "IP address of NTP Server. Use internet dot-decimal notation when providing the address." DEFVAL { "0.0.0.0" } ::= { fwuHstGeneral 20 } fwuSyncNTPServer OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable synchronization with NTP server. Change the value from 0 to 1 to enable synchronization with the NTP Server." DEFVAL { 0 } ::= { fwuHstGeneral 21 } -- .15.2.1.1.1.1.2 fwuHstExt OBJECT IDENTIFIER ::= { fwuHstSystemLevelInfo 2 } fwuHstMajorContactAlarmOutput OBJECT-TYPE SYNTAX CONTACTType MAX-ACCESS read-only STATUS current DESCRIPTION "Host Major contact output port state. Not present, OK and faulted are the supported states." ::= { fwuHstExt 1 } fwuHstMinorContactAlarmOutput OBJECT-TYPE SYNTAX CONTACTType MAX-ACCESS read-only STATUS current DESCRIPTION "Host Minor contact output port state. Not present, OK and faulted are the supported states." ::= { fwuHstExt 2 } fwuRmtMajorContactAlarmOutput OBJECT-TYPE SYNTAX CONTACTType MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Major contact output port state. Not present, OK and faulted are the supported states." ::= { fwuHstExt 3 } fwuRmtMinorContactAlarmOutput OBJECT-TYPE SYNTAX CONTACTType MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Minor contact output port state. Not present, OK and faulted are the supported states." ::= { fwuHstExt 4 } fwuSystemActiveAlarms OBJECT IDENTIFIER ::= { fwuHstSystemLevelInfo 3 } fwuSystemActiveAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuSystemActiveAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table lists all the outstanding (active) alarms in the system. Alarms are removed from this table when the alarm condition is cleared (i.e. When CLEAR is sent out)." ::= { fwuSystemActiveAlarms 1 } fwuSystemActiveAlarmEntry OBJECT-TYPE SYNTAX FwuSystemActiveAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for active alarms." INDEX { fwuSystemAlarmSequenceNumber } ::= { fwuSystemActiveAlarmTable 1 } FwuSystemActiveAlarmEntry ::= SEQUENCE { fwuSystemAlarmSequenceNumber Unsigned32, fwuSystemAlarmTrapNodeAddress UnitID2, fwuSystemlabel DisplayString, fwuSystemAlarmRmtName DisplayString, fwuSystemAlarmRmtType UnitType, fwuSystemAlarmModuleType MODULEType, fwuSystemAlarmModuleNumber Unsigned32, fwuSystemAlarmModuleName DisplayString, fwuSystemAlarmSeverity ALARMType, fwuSystemAlarmRFBand DisplayString, fwuSystemAlarmTimeStamp DateAndTime, fwuSystemAlarmCode Unsigned32, fwuSystemAlarmHstNbr Unsigned32, fwuSystemAlarmAnalogAddress UnitID3 } fwuSystemAlarmSequenceNumber OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The number of the alarm table entry which is defined by this row." ::= { fwuSystemActiveAlarmEntry 1 } fwuSystemAlarmTrapNodeAddress OBJECT-TYPE SYNTAX UnitID2 MAX-ACCESS read-only STATUS current DESCRIPTION "System Node Address, where the alarm originated." ::= { fwuSystemActiveAlarmEntry 2 } fwuSystemlabel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name used to identify the system. Since the Host name is used to identify the system, the Host name is reflected here." ::= { fwuSystemActiveAlarmEntry 3 } fwuSystemAlarmRmtName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the unit from which the alarm originated." ::= { fwuSystemActiveAlarmEntry 4 } fwuSystemAlarmRmtType OBJECT-TYPE SYNTAX UnitType MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the unit from which the alarm originated. fwuSystemAlarmRmtName is the user provided name of this unit." ::= { fwuSystemActiveAlarmEntry 5 } fwuSystemAlarmModuleType OBJECT-TYPE SYNTAX MODULEType MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the Module from which the alarm originated. e.g SeRF, DART, SFP. To be read with fwuSystemAlarmRmtType. Then, it identifies the module on that (fwuSystemAlarmRmtType) unit." ::= { fwuSystemActiveAlarmEntry 6 } fwuSystemAlarmModuleNumber OBJECT-TYPE SYNTAX Unsigned32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the module from which the alarm originated. To be used in conjuction with the object fwuSystemAlarmModuleType. So, if module type indicated DART and module number reported 3, then it means that the alarm originated from the third DART." ::= { fwuSystemActiveAlarmEntry 7 } fwuSystemAlarmModuleName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the Module from which the alarm originated. The user provided name of the module identified by fwuSystemAlarmModuleNumber. " ::= { fwuSystemActiveAlarmEntry 8 } fwuSystemAlarmSeverity OBJECT-TYPE SYNTAX ALARMType MAX-ACCESS read-only STATUS current DESCRIPTION "Severity of the alarm." ::= { fwuSystemActiveAlarmEntry 9 } fwuSystemAlarmRFBand OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The RF band affected by this alarm condition." ::= { fwuSystemActiveAlarmEntry 10 } fwuSystemAlarmTimeStamp OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Time when the alarm is raised." ::= { fwuSystemActiveAlarmEntry 11 } fwuSystemAlarmCode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "A positive number which uniquely identifies an alarm." ::= { fwuSystemActiveAlarmEntry 12 } fwuSystemAlarmHstNbr OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number identifying the host in the system." ::= { fwuSystemActiveAlarmEntry 13 } fwuSystemAlarmAnalogAddress OBJECT-TYPE SYNTAX UnitID3 MAX-ACCESS read-only STATUS current DESCRIPTION "Analog Portion of the node address." ::= { fwuSystemActiveAlarmEntry 14 } -- .15.2.1.1.1.2 fwuHstSystemLevelTraps OBJECT IDENTIFIER ::= { fwuHstSystemLevelObjects 2 } --.1.3.6.1.4.1.2014.15.2.1.1.1.2.2 fwuHstModuleMissingFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Missing Host pluggable module." ::= { fwuHstSystemLevelTraps 2 } --.1.3.6.1.4.1.2014.15.2.1.1.1.2.3 fwuHstOverTempFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host Temperature above operating limit." ::= { fwuHstSystemLevelTraps 3 } --.1.3.6.1.4.1.2014.15.2.1.1.1.2.4 fwuHstUnderTempFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host Temperature below operating limit." ::= { fwuHstSystemLevelTraps 4 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Rev-7 : System/Link Traps -- -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- .15.2.1.1.1.2.5 -- fwuHstBTSUnderPowerFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Band specific alarm FLM raised when unit connected to BTS." ::= { fwuHstSystemLevelTraps 5 } -- .15.2.1.1.1.2.6 -- fwuHstFLMDownconvertFailureFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Forward Link Monitor (FLM) fault active." ::= { fwuHstSystemLevelTraps 6 } -- .15.2.1.1.1.2.7 -- fwuHstRLMUpconvertFailureFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Band specific alarm RLM raised when unit connected to BTS." ::= { fwuHstSystemLevelTraps 7 } -- .15.2.1.1.1.2.8 -- fwuHstRLMUpConIndetFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Unable to run RLM due to Host Reverse gain being set too low." ::= { fwuHstSystemLevelTraps 8 } -- .15.2.1.1.1.2.9 -- fwuHstIamAliveFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuHstNumber, fwuHstName, fwuNotificationStatus } STATUS current DESCRIPTION "The Host I am alive Trap" ::= { fwuHstSystemLevelTraps 9 } fwuHstSERFObjects OBJECT IDENTIFIER ::= { fwuHostUnitObjects 2 } fwuHstSERFInfo OBJECT IDENTIFIER ::= { fwuHstSERFObjects 1 } fwuHstSERFGeneral OBJECT IDENTIFIER ::= { fwuHstSERFInfo 1 } fwuHstSERFLinuxKernelVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Linux Kernel version on host." ::= { fwuHstSERFGeneral 1 } fwuHstSERFLinuxBootLoaderVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Boot Loader1 version on host." ::= { fwuHstSERFGeneral 2 } fwuHstSERFCompactFlashSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Compact Flash version on host." ::= { fwuHstSERFGeneral 3 } fwuHstSERFFPGAVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "FPGA version loaded on Host SeRF." ::= { fwuHstSERFGeneral 4 } fwuHstSERFPPCSNMPAgentSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SNMP agent version on host." ::= { fwuHstSERFGeneral 5 } fwuHstSERFPPCHWMonSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware Monitor process version on host." ::= { fwuHstSERFGeneral 6 } fwuHstSERFPPCAPPMonSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Application Monitor process version on host." ::= { fwuHstSERFGeneral 7 } fwuHstSERFPPCMATEMonSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Mate Monitor process version on host." ::= { fwuHstSERFGeneral 8 } fwuHstSERFPPCENETMonSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet Monitor process version on host." ::= { fwuHstSERFGeneral 9 } fwuHstSERFPPCFPGAMonSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "FPGA Monitor process version on host." ::= { fwuHstSERFGeneral 10 } fwuHstSERFRIDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host SeRF Inventory - Date Code." ::= { fwuHstSERFGeneral 11 } fwuHstSERFRIHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host SeRF Inventory - Hardware version." ::= { fwuHstSERFGeneral 12 } fwuHstSERFRISerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host SeRF Inventory - Serial Number." ::= { fwuHstSERFGeneral 13 } fwuHstSERFRIADCPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host SeRF Inventory - TE PartNumber." ::= { fwuHstSERFGeneral 14 } fwuHstSERFRIHWGen OBJECT-TYPE SYNTAX INTEGER { firstGeneration(0), secondGeneration(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Host SeRF Hardware Generation." ::= { fwuHstSERFGeneral 15 } fwuHstSERFLinuxBootLoaderFirstVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Boot Loader2 version of the host system." ::= { fwuHstSERFGeneral 16 } fwuHstpThreadSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version number of pThread process. If blank then pThread does not run here." ::= { fwuHstSERFGeneral 17 } fwuHstSubagentSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version number of the subagent." ::= { fwuHstSERFGeneral 18 } fwuHstWebServerSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version number of web server." ::= { fwuHstSERFGeneral 19 } --+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Host SeRF Optical Objects; -- OID: .15.2.1.1.2.1.2 -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuHstSERFOptObjects OBJECT IDENTIFIER ::= { fwuHstSERFInfo 2 } fwuHstSERFOptTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuHstSERFOptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of Host SERF Optical Objects." ::= { fwuHstSERFOptObjects 1 } fwuHstSERFOptEntry OBJECT-TYPE SYNTAX FwuHstSERFOptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to Host SERF Optical objects." INDEX { fwuHstSERFOptSFPNumber } ::= { fwuHstSERFOptTable 1 } FwuHstSERFOptEntry ::= SEQUENCE { fwuHstSERFOptSFPNumber Integer32, fwuHstSERFOptSFPName DisplayString, fwuHstSERFOptSFPType OPTICSType, fwuHstSERFOptSFPTxColor Integer32, fwuHstSERFOptRevLaunchPowerMeas DisplayString, fwuHstSERFOptFwdLaunchPowerMeas DisplayString, fwuHstSERFOptMateName DisplayString, fwuHstSERFIPEnable INTEGER, fwuHstSERFOptMateId UnitID2, fwuHstSERFOptMateSfpId Integer32 } fwuHstSERFOptSFPNumber OBJECT-TYPE SYNTAX Integer32 (1 .. 8) MAX-ACCESS read-only STATUS current DESCRIPTION "SFP Number - Optical Port number." ::= { fwuHstSERFOptEntry 1 } fwuHstSERFOptSFPName OBJECT-TYPE SYNTAX DisplayString ( SIZE(0 .. 64) ) MAX-ACCESS read-write STATUS current DESCRIPTION "User defined name of each Host SFP. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters." DEFVAL { "SFP" } ::= { fwuHstSERFOptEntry 2 } fwuHstSERFOptSFPType OBJECT-TYPE SYNTAX OPTICSType MAX-ACCESS read-only STATUS current DESCRIPTION "SFP Type - Optical Port Type. Identifies whether the SFP is short(1)/intermediate(2)/long(3) range. It may also be unidentified (-1)." ::= { fwuHstSERFOptEntry 3 } fwuHstSERFOptSFPTxColor OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Wavelength of light used in the SFP (in nanometers)." ::= { fwuHstSERFOptEntry 4 } fwuHstSERFOptRevLaunchPowerMeas OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the optical power, in dBm received at the host." ::= { fwuHstSERFOptEntry 5 } fwuHstSERFOptFwdLaunchPowerMeas OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the optical power, in dBm transmitted by the host." ::= { fwuHstSERFOptEntry 6 } fwuHstSERFOptMateName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of Host Mates." ::= { fwuHstSERFOptEntry 7 } fwuHstSERFIPEnable OBJECT-TYPE SYNTAX INTEGER { iPEnable(1), iPDisable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether IP is enabled(1) or not(2)." ::= { fwuHstSERFOptEntry 8 } fwuHstSERFOptMateId OBJECT-TYPE SYNTAX UnitID2 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of (companion) mate unit." ::= { fwuHstSERFOptEntry 9 } fwuHstSERFOptMateSfpId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "SFP slot number used at remote end." ::= { fwuHstSERFOptEntry 10 } fwuHstSERFTraps OBJECT IDENTIFIER ::= { fwuHstSERFObjects 2 } --.1.3.6.1.4.1.2014.15.2.1.1.2.2.2 fwuHstSERFSynthAlarmFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host SeRF synthesizer unlocked." ::= { fwuHstSERFTraps 2 } -- .1.3.6.1.4.1.2014.15.2.1.1.2.2.3 fwuHstSERFFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Summary of SeRF Synthesizer Unlocked alarm and SeRF FPGA status. The system may not be communicating with the Ethernet Switch. This fault is also precipitated by the I2C Bus Fault." ::= { fwuHstSERFTraps 3 } -- .1.3.6.1.4.1.2014.15.2.1.1.2.2.4 fwuHstSERFRmtLostFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Remote is not communicating with Host." ::= { fwuHstSERFTraps 4 } -- .1.3.6.1.4.1.2014.15.2.1.1.2.2.5 -- fwuHstSERFOptRxBERFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "High bit error rate (BER) detected by fiber optic receiver." ::= { fwuHstSERFTraps 5 } -- .1.3.6.1.4.1.2014.15.2.1.1.2.2.6 -- fwuHstSERFOptRxNoLightFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "No signal detected by optical receiver." ::= { fwuHstSERFTraps 6 } -- .1.3.6.1.4.1.2014.15.2.1.1.2.2.7 -- fwuHstSERFOptLaserFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "SFP optical transmitter failed." ::= { fwuHstSERFTraps 7 } --.1.3.6.1.4.1.2014.15.2.1.1.2.2.8 -- fwuHstSERFOptOverDriveFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "SFP optical receive input power above specification." ::= { fwuHstSERFTraps 8 } -- .1.3.6.1.4.1.2014.15.2.1.1.2.2.9 -- fwuHstSERFOptUnderDriveFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "SFP optical receive input power below specification." ::= { fwuHstSERFTraps 9 } -- .1.3.6.1.4.1.2014.15.2.1.1.2.2.10 -- fwuHstSERFOptIpEnableFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host SFP IPEnable Fault." ::= { fwuHstSERFTraps 10 } -- .1.3.6.1.4.1.2014.15.2.1.1.2.2.11 -- fwuMastClockPriorityLvlConflict NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "More than one Host has the same Master Clock Priority Level. All Hosts in conflict raise the alarm." ::= { fwuHstSERFTraps 11 } -- .1.3.6.1.4.1.2014.15.2.1.1.2.2.12 -- fwuHstI2CBus1Fault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Indicates an I2C communication problem." ::= { fwuHstSERFTraps 12 } -- .1.3.6.1.4.1.2014.15.2.1.1.2.2.13 -- fwuHstI2CBus2Fault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Indicates an I2C communication problem." ::= { fwuHstSERFTraps 13 } fwuHstSERFEthPortObjects OBJECT IDENTIFIER ::= { fwuHostUnitObjects 3 } fwuHstSERFEthPortInfo OBJECT IDENTIFIER ::= { fwuHstSERFEthPortObjects 1 } fwuHstSERFEthPortTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuHstSERFEthPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains information of Host Ethernet Ports." ::= { fwuHstSERFEthPortInfo 1 } fwuHstSERFEthPortEntry OBJECT-TYPE SYNTAX FwuHstSERFEthPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to Host SERF Ethernet port objects." INDEX { fwuHstSERFEthPortNumber } ::= { fwuHstSERFEthPortTable 1 } FwuHstSERFEthPortEntry ::= SEQUENCE { fwuHstSERFEthPortNumber Unsigned32, fwuHstSERFEthPortType ENETType, fwuHstSERFEthPortRxBytes Counter64, fwuHstSERFEthPortRxPkts Counter64, fwuHstSERFEthPortRxFcsErrors Counter64, fwuHstSERFEthPortRxBroadcastPkts Counter64, fwuHstSERFEthPortRxMulticastPkts Counter64, fwuHstSERFEthPortRxFragmtdFrames Counter64, fwuHstSERFEthPortRxJabbersFrames Counter64, fwuHstSERFEthPortTxByteCounter Counter64, fwuHstSERFEthPortTxPkts Counter64, fwuHstSERFEthPortTxBroadcastPkts Counter64, fwuHstSERFEthPortTxMulticastPkts Counter64, fwuHstSERFEthPortSFPId Integer32 } fwuHstSERFEthPortNumber OBJECT-TYPE SYNTAX Unsigned32 (1 .. 12) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier for each Ethernet port." ::= { fwuHstSERFEthPortEntry 1 } fwuHstSERFEthPortType OBJECT-TYPE SYNTAX ENETType MAX-ACCESS read-only STATUS current DESCRIPTION "An identifier for the type of Ethernet port. The port types are network(1), craft(2) , management(3) , switch(4) , SFP(5). It may be unknown (-1)." ::= { fwuHstSERFEthPortEntry 2 } fwuHstSERFEthPortRxBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Count of the number of recieved bytes at this ethernet port." ::= { fwuHstSERFEthPortEntry 3 } fwuHstSERFEthPortRxPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets recieved at this ethernet port." ::= { fwuHstSERFEthPortEntry 4 } fwuHstSERFEthPortRxFcsErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of FCS errors recieved at this ethernet port." ::= { fwuHstSERFEthPortEntry 5 } fwuHstSERFEthPortRxBroadcastPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of broadcast packets recieved at this ethernet port." ::= { fwuHstSERFEthPortEntry 6 } fwuHstSERFEthPortRxMulticastPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of multicast packets at this ethernet port." ::= { fwuHstSERFEthPortEntry 7 } fwuHstSERFEthPortRxFragmtdFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of fragmented frames received at this ethernet port." ::= { fwuHstSERFEthPortEntry 8 } fwuHstSERFEthPortRxJabbersFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of jabber frames received at this ethernet port." ::= { fwuHstSERFEthPortEntry 9 } fwuHstSERFEthPortTxByteCounter OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes transmitted from this ethernet port." ::= { fwuHstSERFEthPortEntry 10 } fwuHstSERFEthPortTxPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets transmitted from this ethernet port." ::= { fwuHstSERFEthPortEntry 11 } fwuHstSERFEthPortTxBroadcastPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of broadcast packets transmitted from this ethernet port." ::= { fwuHstSERFEthPortEntry 12 } fwuHstSERFEthPortTxMulticastPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of multicast packets transmitted from this ethernet port." ::= { fwuHstSERFEthPortEntry 13 } fwuHstSERFEthPortSFPId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the SFP number to which this ethernet port connects." ::= { fwuHstSERFEthPortEntry 14 } fwuHstSERFEthPortTraps OBJECT IDENTIFIER ::= { fwuHstSERFEthPortObjects 2 } fwuHstSERFFPGAObjects OBJECT IDENTIFIER ::= { fwuHostUnitObjects 4 } fwuHstSERFFPGAInfo OBJECT IDENTIFIER ::= { fwuHstSERFFPGAObjects 1 } fwuHstSERFFPGAStatus OBJECT-TYPE SYNTAX INTEGER { ppcCanTalkToFPGA(0), ppcCanNotTalkToFPGA(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Provides the SERF Card FPGA status. The status may be PPC can communicate with the FPGA (0) or not (1)." DEFVAL { 0 } ::= { fwuHstSERFFPGAInfo 1 } fwuHstSERFFPGATraps OBJECT IDENTIFIER ::= { fwuHstSERFFPGAObjects 2 } fwuHstMateMonObjects OBJECT IDENTIFIER ::= { fwuHostUnitObjects 5 } fwuHstMateMonInfo OBJECT IDENTIFIER ::= { fwuHstMateMonObjects 1 } fwuHstMateMonTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuHstMateMonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of Host Mate Monitor." ::= { fwuHstMateMonInfo 1 } fwuHstMateMonEntry OBJECT-TYPE SYNTAX FwuHstMateMonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to host Mate monitor objects." INDEX { fwuHMmonRmtID } ::= { fwuHstMateMonTable 1 } FwuHstMateMonEntry ::= SEQUENCE { fwuHMmonRmtID UnitID2, fwuHMmonRmtIPAddress OCTET STRING } fwuHMmonRmtID OBJECT-TYPE SYNTAX UnitID2 MAX-ACCESS read-only STATUS current DESCRIPTION "ID of companion remote unit as Index of mate monitor table." ::= { fwuHstMateMonEntry 1 } fwuHMmonRmtIPAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "IP addresses of remote mate. This is a link-local address." ::= { fwuHstMateMonEntry 2 } fwuHstDARTObjects OBJECT IDENTIFIER ::= { fwuHostUnitObjects 6 } fwuHstDARTInfo OBJECT IDENTIFIER ::= { fwuHstDARTObjects 1 } fwuHstDARTGeneral OBJECT IDENTIFIER ::= { fwuHstDARTInfo 1 } fwuHstDARTGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuHstDARTGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of Host DART Card." ::= { fwuHstDARTGeneral 1 } fwuHstDARTGeneralEntry OBJECT-TYPE SYNTAX FwuHstDARTGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to host DART Card objects." INDEX { fwuHstDARTNumber } ::= { fwuHstDARTGeneralTable 1 } FwuHstDARTGeneralEntry ::= SEQUENCE { fwuHstDARTNumber Integer32, fwuHstDARTName DisplayString, fwuHstDARTBandType BANDType, fwuHstDARTPassBand OCTET STRING, fwuHstDARTOperatingMode MODEType, fwuHstDARTDiversityStatus INTEGER, fwuHstDARTForwardGain GAINType, fwuHstDARTReverseGain GAINType, fwuHstDARTFPGAStatus INTEGER, fwuHstDARTFPGAProgramVer DisplayString, fwuHstDARTRIADCPartNumber DisplayString, fwuHstDARTRISerialNumber DisplayString, fwuHstDARTRIDateCode DisplayString, fwuHstDARTRIHWVer DisplayString, fwuHstDARTRowStatus RowStatus, fwuHstDARTPeakInputPwrLvl1 DisplayString, fwuHstDARTPeakInputPwrLvl2 DisplayString, fwuHstDARTPeakAvgInputPwrLvl1 DisplayString, fwuHstDARTPeakAvgInputPwrLvl2 DisplayString, fwuHstDARTMinAvgInputPwrLvl1 DisplayString, fwuHstDARTMinAvgInputPwrLvl2 DisplayString, fwuHstDARTInputPowerMode INTEGER, fwuHstDARTPwrLevelMaxHoldReset INTEGER, fwuHstDARTLastMaxHoldResetTime OCTET STRING, fwuHstDARTInputSrc INTEGER } fwuHstDARTNumber OBJECT-TYPE SYNTAX Integer32 (1 .. 8) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier for each DART. As there are eight DART slots, the number may be any of 1 to 8." ::= { fwuHstDARTGeneralEntry 1 } fwuHstDARTName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "A user defined name for each DART Card object of host. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters." DEFVAL { "DART" } ::= { fwuHstDARTGeneralEntry 2 } fwuHstDARTBandType OBJECT-TYPE SYNTAX BANDType MAX-ACCESS read-only STATUS current DESCRIPTION "Band type of host DART card." DEFVAL { -1 } ::= { fwuHstDARTGeneralEntry 3 } fwuHstDARTPassBand OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is for configuration of Pass-band type for host DART card. Following input formats are supported for Classic and SuperDart passband configuration. 1. For Classic Darts only, User input string would be enumeration value ( i.e., 'x'), ranging from 1 to 134. See below in section 3. for valid values. 2. For SuperDarts only, a. BandType_SubBand1+SubBand2 This is applicable only for contiguous passband selection, applicable only for PCS & AWS. (e.g., 'PCS_A1+A2+A3') b. BandType_SubBand1+SubBand2:SubBand5+SubBand6 This is applicable for noncontiguous passband selection, applicable only for PCS & AWS. (e.g., 'PCS_A1+A2:C2+C1') c. BandType_StartFrequency-StartFrequency This is applicable only for contiguous passband frequency range. (e.g.,, PCS_1930-1945) d. BandType_StartFrequency1-StartFrequency1:StartFrequency2-StartFrequency2 This is applicable only for noncontiguous passband frequency ranges. (e.g., PCS_1930-1940.5:1960.7-1970.6). Where BandType is 'PCS', 'AWS', 'UMTS','EGSM900','GSM1800', 'UC700', 'LABC700'. 3. Valid enumeration value for classic dart:- undefined(-1), cellularA2A(1),cellularA(2),cellularAA1A2(3),cellularA1(4), cellularB(5),cellularB1(6),cellularBB1(7), pcsA1(8),pcsA2(9),pcsA3(10),pcsB1(11),pcsB2(12),pcsB3(13), pcsC3(14),pcsC4(15),pcsC5(16),pcsD(17),pcsE(18),pcsF(19), pcsG(20),awsH(21),pcsC2(22), pcsC1(23), pcsA1A2(24),pcsA2A3(25),pcsA3D(26),pcsDB1(27),pcsB1B2(28),pcsB2B3(29), pcsB3E(30),pcsEF(31),pcsFC3(32), pcsC3C4(33),pcsC4C5(34), pcsC5G(35),pcsGawsH(36),pcsFC2(37),pcsC1G(38),pcsA(39), pcsA2A3D(40),pcsA3DB1(41), pcsDB1B2(42),pcsB(43),pcsB2B3E(44), pcsB3EF(45),pcsEFC3(46),pcsFC3C4(47),pcsC(48), pcsC4C5G(49), pcsC5GawsH(50),pcsEFC2(51),pcsC1GawsH(52), pcsAD(53),pcsA2A3DB1(54),pcsA3DB1B2(55),pcsDB(56),pcsBE(57), pcsB2B3EF(58),pcsB3EFC3(59),pcsEFC3C4(60),pcsFC(61), pcsCG(62),pcsC4C5GawsH(63),pcsB3EFC2(64), pcsADB1(65),pcsA2A3DB1B2(66),pcsA3DB(67),pcsDBE(68), pcsBEF(69),pcsB2B3EFC3(70),pcsB3EFC3C4(71),pcsEFC(72), pcsFCG(73),pcsCGawsH(74),pcsB2B3EFC2(75), pcsADB1B2(76),pcsA2A3DB(77),pcsA3DBE(78),pcsDBEF(79), pcsBEFC3(80),pcsB2B3EFC3C4(81),pcsB3EFC(82), pcsEFCG(83),pcsFCGawsH(84),pcsADB(85), pcsA2A3DBE(86),pcsA3DBEF(87), pcsDBEFC3(88), pcsBEFC3C4(89),pcsB2B3EFC(90),pcsB3EFCG(91), pcsEFCGawsH(92),smrLow(93) , smrHigh( 94), awsA(95), awsAB(96), awsABC(97), awsABCD(98), awsABCDE(99), awsB(100), awsBC(101), awsBCD(102), awsBCDE(103), awsBCDEF(104), awsC(105), awsCD(106), awsCDE(107), awsCDEF(108), awsD(109), awsDE(110), awsDEF(111), awsE(112), awsEF(113), awsF(114), smrLowWide(115), cellularA2ABA1B1(116), GSM1800Low(117), GSM1800Middle(118), GSM1800High(119), umtsLow(120), umtsMiddle(121), umtsHigh(122), cellularAB(133), apac800iDEN(134)." ::= { fwuHstDARTGeneralEntry 4 } fwuHstDARTOperatingMode OBJECT-TYPE SYNTAX MODEType MAX-ACCESS read-create STATUS current DESCRIPTION "Operating mode of the Host DART. The DART may be operating normally (1) or on standby (2). The mode may be undefined (-1)." DEFVAL { 1 } ::= { fwuHstDARTGeneralEntry 5 } fwuHstDARTDiversityStatus OBJECT-TYPE SYNTAX INTEGER { nonDiversity(0) , diversity(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Diversity Status of host DART." DEFVAL { 0 } ::= { fwuHstDARTGeneralEntry 6 } fwuHstDARTForwardGain OBJECT-TYPE SYNTAX GAINType MAX-ACCESS read-create STATUS current DESCRIPTION "Primary Gain in the forward path of Host DART. The range is 0-31dB with increments in steps of 1dB." DEFVAL { 0 } ::= { fwuHstDARTGeneralEntry 7 } fwuHstDARTReverseGain OBJECT-TYPE SYNTAX GAINType MAX-ACCESS read-create STATUS current DESCRIPTION "Primary Gain in the reverse path of Host DART. The range is 0-31dB with increments in steps of 1dB." DEFVAL { 0 } ::= { fwuHstDARTGeneralEntry 8 } fwuHstDARTFPGAStatus OBJECT-TYPE SYNTAX INTEGER { serfFpgaCanTalkToDARTFpga(0), serfFpgaCannotTalkToDARTFpga(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Host DART FPGA Status. It indicates whether the SeRF FPGA can talk to DART FPGA(0) or not (1)." DEFVAL { 0 } ::= { fwuHstDARTGeneralEntry 9 } fwuHstDARTFPGAProgramVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "FPGA Version on the Host DART card." ::= { fwuHstDARTGeneralEntry 10 } fwuHstDARTRIADCPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host DART Inventory Data - TE Part Number." ::= { fwuHstDARTGeneralEntry 11 } fwuHstDARTRISerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host DART Inventory Data - Serial Number." ::= { fwuHstDARTGeneralEntry 12 } fwuHstDARTRIDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host DART Inventory Data - DateCode." ::= { fwuHstDARTGeneralEntry 13 } fwuHstDARTRIHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host DART Inventory Data - HW version." ::= { fwuHstDARTGeneralEntry 14 } fwuHstDARTRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. It may be active or inactive." ::= { fwuHstDARTGeneralEntry 15 } fwuHstDARTPeakInputPwrLvl1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Peak Input Power Level 1 to a Host DART." DEFVAL { "NA" } ::= { fwuHstDARTGeneralEntry 16 } fwuHstDARTPeakInputPwrLvl2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Peak Input Power Level 2 to a Host DART. Incase of diversity, this value will be NA." DEFVAL { "NA" } ::= { fwuHstDARTGeneralEntry 17 } fwuHstDARTPeakAvgInputPwrLvl1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Peak Average Input Power Level1 to a Host DART." DEFVAL { "NA" } ::= { fwuHstDARTGeneralEntry 18 } fwuHstDARTPeakAvgInputPwrLvl2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Peak Average Input Power Level 2 to a Host DART. Incase of diversity, this value will be NA." DEFVAL { "NA" } ::= { fwuHstDARTGeneralEntry 19 } fwuHstDARTMinAvgInputPwrLvl1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum Average Input Power Level 1 to a Host DART." DEFVAL { "NA" } ::= { fwuHstDARTGeneralEntry 20 } fwuHstDARTMinAvgInputPwrLvl2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum Average Input Power Level 2 to a Host DART. Incase of diversity, this value will be NA." DEFVAL { "NA" } ::= { fwuHstDARTGeneralEntry 21 } fwuHstDARTInputPowerMode OBJECT-TYPE SYNTAX INTEGER { snapShot(0) , maxHold(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Host DART Input Power Level Mode. The supported modes are Snapshot(0) and Max Hold(1). When setting Max Hold, ensure that the status (fwuHstDARTDiversityStatus) is not diversity." DEFVAL { 0 } ::= { fwuHstDARTGeneralEntry 22 } fwuHstDARTPwrLevelMaxHoldReset OBJECT-TYPE SYNTAX INTEGER { notApplicable(-1), normal(0) , reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to reset the Max Hold reading. Used when the input power mode is Max hold. Reset by changing from normal (0) to reset (1). Status will revert to normal once the reset is done. In snapshot mode (see fwuHstDARTInputPowerMode) this object is not applicable (-1)." DEFVAL { -1 } ::= { fwuHstDARTGeneralEntry 23 } fwuHstDARTLastMaxHoldResetTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Date and Time of the last Max Hold reset on the host DART." ::= { fwuHstDARTGeneralEntry 24 } fwuHstDARTInputSrc OBJECT-TYPE SYNTAX INTEGER { bts ( 1 ), bda ( 2 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "To identify the input source; BTS(1) or BDA(2) and change it, if required." DEFVAL { 1 } ::= { fwuHstDARTGeneralEntry 25 } fwuHstDARTTraps OBJECT IDENTIFIER ::= { fwuHstDARTObjects 2 } fwuHstDARTDwnCon1SynLockFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DART downconverter 1 synthesizer unlocked." ::= { fwuHstDARTTraps 2 } fwuHstDARTDwnCon2SynLockFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DART downconverter 2 synthesizer unlocked." ::= { fwuHstDARTTraps 3 } fwuHstDARTUpConSynLockFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DART upconverter synthesizer unlocked." ::= { fwuHstDARTTraps 4 } fwuHstDARTOverDriveFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DART forward RF input too high." ::= { fwuHstDARTTraps 5 } fwuHstDARTUnderDriveFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DART forward RF input signal below the normal operating limit." ::= { fwuHstDARTTraps 6 } fwuHstDARTFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Summary of DART Downconverter 1 Synthesizer Unlocked, Downconverter 2 Synthesizer Unlocked, Upconverter Synthesizer Unlocked, DC Supply Fault alarms, and DART FPGA status." ::= { fwuHstDARTTraps 7 } fwuHstDARTDCSupplyFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DART card DC supply voltages outside specification." ::= { fwuHstDARTTraps 8 } fwuHstDARTHardwareMismatchFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host DART does not support the selected passband. Fault occurs when a Host DART is replaced with another DART of the incorrect type." ::= { fwuHstDARTTraps 9 } fwuHstDARTALCLimitingFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host DART forward path Automatic Level Control is active." ::= { fwuHstDARTTraps 10 } fwuHstDARTLinkingConflictFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host comes back up and finds that it cannot restore a link with a remote DART to which it was linked." ::= { fwuHstDARTTraps 11 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- (.15.2.1.4) -- fwuHstSystemCardObjects OBJECT IDENTIFIER ::= { fwuHostUnitObjects 7 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuHstSystemCardInfo OBJECT IDENTIFIER ::= { fwuHstSystemCardObjects 1 } fwuHstSysCardRIADCPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host Inventory Data - TE Part Number." ::= { fwuHstSystemCardInfo 1 } fwuHstSysCardRISerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host Inventory Data - Serial Number." ::= { fwuHstSystemCardInfo 2 } fwuHstSysCardRIDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host Inventory Data - Date Code." ::= { fwuHstSystemCardInfo 3 } fwuHstSysCardRIHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host Inventory Data - Hardware version." ::= { fwuHstSystemCardInfo 4 } fwuHstSysCard10MhzRefClock OBJECT-TYPE SYNTAX INTEGER { internal(0) , external(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "System Card Reference clock. It may be set to internal (0) or external(1)." ::= { fwuHstSystemCardInfo 5 } -- Added Clock Priority Level Object for Multi Host URH fwuHstSysCardCPLevel OBJECT-TYPE SYNTAX Integer32 (1 .. 14) MAX-ACCESS read-write STATUS current DESCRIPTION "System Card Master Clock Priority Level prioritizes the system card clock using values 1 through 14 (Lower value is higher priority). This is primarily used in multihost systems. In such system, all hosts should have different priority levels, and the system inherently assures this. This entity allows the user to change the system set prioritization. Changeing values in a single host system has no change." ::= { fwuHstSystemCardInfo 6 } fwuHstSysCardOutputRefClock OBJECT-TYPE SYNTAX INTEGER { off (0), clock10mhz(1) , clock30mhz(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "System Card Reference clock. System Board I supports only 10 MHz and System Board II supports both 10 MHz and 30 MHz Clock output. Default value is 1 for Host and 2 for DRU." DEFVAL { 1 } ::= { fwuHstSystemCardInfo 7 } fwuHstSysCardRIHWGen OBJECT-TYPE SYNTAX INTEGER { firstGeneration(0), secondGeneration(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Host System Card Hardware Generation. Presently, there are two generations; first Generation(0), second Generation(1)" ::= { fwuHstSystemCardInfo 8 } fwuHstSystemCardTraps OBJECT IDENTIFIER ::= { fwuHstSystemCardObjects 2 } fwuHstSysCardFanFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Fan not functioning." ::= { fwuHstSystemCardTraps 2 } fwuHstSysCardClockMismatchFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "System Card output clock not supported." ::= { fwuHstSystemCardTraps 3 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Remote Unit Objects; -- OID: 15.2.1.2 -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuRemoteUnitObjects OBJECT IDENTIFIER ::= { flexwaveURHMibModule 2 } fwuRmtSystemLevelObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 1 } fwuRmtSystemLevelInfo OBJECT IDENTIFIER ::= { fwuRmtSystemLevelObjects 1 } fwuRmtGeneral OBJECT IDENTIFIER ::= { fwuRmtSystemLevelInfo 1 } fwuRmtGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of remote." ::= { fwuRmtGeneral 1 } fwuRmtGeneralEntry OBJECT-TYPE SYNTAX FwuRmtGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to remote objects." INDEX { fwuRmtNumber } ::= { fwuRmtGeneralTable 1 } FwuRmtGeneralEntry ::= SEQUENCE { fwuRmtNumber UnitID2, fwuRmtCatalogState CATALOGType, fwuRmtName DisplayString, fwuRmtAlarmStatusSummary ALARMType, fwuRmtTempMeasurement DisplayString, fwuRmtGeneralTableRowStatus RowStatus, fwuRmtType UnitType, fwuDruIfCombinerReboot Unsigned32, fwuUsrCommLinkTestIFBr INTEGER, fwuUsrCommLinkTestIFBrDType BANDType, fwuUsrCommLinkTestDartId Unsigned32, fwuDruBackPlaneRev OCTET STRING, fwuPrismUnitReset INTEGER } fwuRmtNumber OBJECT-TYPE SYNTAX UnitID2 MAX-ACCESS read-only STATUS current DESCRIPTION "The Node address of connected remote." ::= { fwuRmtGeneralEntry 1 } fwuRmtCatalogState OBJECT-TYPE SYNTAX CATALOGType MAX-ACCESS read-only STATUS current DESCRIPTION "Catalog state of remote. If fwuRmtCatalogState is commission(2), then start commissioning on remote, else if it in normal, do not commission the remote." ::= { fwuRmtGeneralEntry 2 } fwuRmtName OBJECT-TYPE SYNTAX DisplayString ( SIZE (0 .. 64) ) MAX-ACCESS read-create STATUS current DESCRIPTION "User defined name of the remote unit. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters." DEFVAL { "Remote" } ::= { fwuRmtGeneralEntry 3 } fwuRmtAlarmStatusSummary OBJECT-TYPE SYNTAX ALARMType MAX-ACCESS read-only STATUS current DESCRIPTION "Summary of alarm status of all connected remote units." ::= { fwuRmtGeneralEntry 4 } fwuRmtTempMeasurement OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of each remote unit in Celsius. This value comes from the RSI." ::= { fwuRmtGeneralEntry 5 } fwuRmtGeneralTableRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. It may be active or inactive." ::= { fwuRmtGeneralEntry 6 } fwuRmtType OBJECT-TYPE SYNTAX UnitType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of Remote. e.g. Prism, DRU, HEU, IRU." ::= { fwuRmtGeneralEntry 7 } fwuDruIfCombinerReboot OBJECT-TYPE SYNTAX Unsigned32 (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Reboot an IF-combiner and all the units connected to it. Only applicable to DRU-IFs Change Value from 0 to 1 to reboot." ::= { fwuRmtGeneralEntry 8 } fwuUsrCommLinkTestIFBr OBJECT-TYPE SYNTAX INTEGER { inactive(0), start(1) , inprogress(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to perform system test on an IF branch. Change from inactive(0) to start(1) to initiate the test. For the duration of the test inprogress(2) is displayed. On completion, inactive is displayed." DEFVAL { 0 } ::= { fwuRmtGeneralEntry 9 } fwuUsrCommLinkTestIFBrDType OBJECT-TYPE SYNTAX BANDType MAX-ACCESS read-write STATUS current DESCRIPTION "Selected Bands i.e. RF DARTs on units when performing system test." ::= { fwuRmtGeneralEntry 10 } fwuUsrCommLinkTestDartId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "To identify the DART ." ::= { fwuRmtGeneralEntry 11 } fwuDruBackPlaneRev OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Provides the back plane revision of the DRU (Three pin version Number of the Chassis back plane)" ::= { fwuRmtGeneralEntry 12 } fwuPrismUnitReset OBJECT-TYPE SYNTAX INTEGER { normal(0), reset(1)} MAX-ACCESS read-write STATUS current DESCRIPTION "Provides a way to reset the Remote SERF card. SET this to reset(1) to trigger a remote unit reset." ::= { fwuRmtGeneralEntry 13 } fwuRmtSystemLevelTraps OBJECT IDENTIFIER ::= { fwuRmtSystemLevelObjects 2 } fwuRmtAcPowerSupplyFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Summary of AC Power Supply 1, AC Power Supply 2, AC Power Supply 3, and AC Power Supply 4 alarms." ::= { fwuRmtSystemLevelTraps 2 } fwuRmtMajorExtAlarmInputFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "The remote Major Ext Alarm Input Fault." ::= { fwuRmtSystemLevelTraps 3 } fwuRmtMinorExtAlarmInputFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "The remote Minor Ext Alarm Input Fault." ::= { fwuRmtSystemLevelTraps 4 } fwuRmtModuleMissingFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "A Remote (DRU/PRU/URU) pluggable module is missing (if DRU: DART or SFP. If PRU/URU: DART, SFP, LNA, LPA, or PD)." ::= { fwuRmtSystemLevelTraps 5 } fwuRmtOverTempFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Remote Temperature above operating limit." ::= { fwuRmtSystemLevelTraps 6 } fwuRmtUnderTempFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Temperature below operating limit." ::= { fwuRmtSystemLevelTraps 7 } fwuRmtOpenDoorFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Door open on PRU." ::= { fwuRmtSystemLevelTraps 8 } fwuRmtFanOverSpeedFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Fans operating above expected RPM." ::= { fwuRmtSystemLevelTraps 9 } fwuRmtFanUnderSpeedFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Fans operating below expected RPM." ::= { fwuRmtSystemLevelTraps 10 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Rev-7 : System/Link Traps -- -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- 15.2.1.2.1.2.11 -- fwuRmtDownLinkCalToneFailureFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Forward calibration tone not at expected level." ::= { fwuRmtSystemLevelTraps 11 } -- 15.2.1.2.1.2.12 -- fwuRmtUplinkFailureDetectLowFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Reverse test tone not at expected level." ::= { fwuRmtSystemLevelTraps 12 } -- 15.2.1.2.1.2.13 -- fwuRmtUpConvertFailureFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Band specific alarm raised during Forward Link Monitoring on PRU/URU." ::= { fwuRmtSystemLevelTraps 13 } -- 15.2.1.2.1.2.14 -- fwuRmtUnderPowerFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Band specific alarm raised during Forward Link Monitoring on PRU/URU." ::= { fwuRmtSystemLevelTraps 14 } -- 15.2.1.2.1.2.15 -- fwuRmtDownConvertFailureFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Band specific alarm raised during Reverse Link Monitoring on PRU/URU." ::= { fwuRmtSystemLevelTraps 15 } -- 15.2.1.2.1.2.16 -- fwuRmtUpconIndetFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Band specific alarm raised during Forward Link Monitoring on PRU/URU." ::= { fwuRmtSystemLevelTraps 16 } -- 15.2.1.2.1.2.17 -- fwuRmtFiberConnMismatchFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Fiber optic cable connections between cascaded DRU/PRUs not following SFP connection rules." ::= { fwuRmtSystemLevelTraps 17 } -- 15.2.1.2.1.2.18 -- fwuRmtExcessConnFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Two or more DRU/PRU/URU connected to a single cascaded DRU/PRU/URU, or a ninth DRU/PRU/URU connected in cascade." ::= { fwuRmtSystemLevelTraps 18 } -- 15.2.1.2.1.2.19 -- fwuRmtInvalidDevConnFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "PRU/URU connected to a DRU or vice versa." ::= { fwuRmtSystemLevelTraps 19 } -- 15.2.1.2.1.2.20 -- fwuDruSysCardClockMismatchFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "System Card output clock not supported." ::= { fwuRmtSystemLevelTraps 20 } -- 15.2.1.2.1.2.21 -- fwuDruNoCommsFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DRU has lost communication with IFEU Or IFEU is disconnected from the DRU." ::= { fwuRmtSystemLevelTraps 21 } fwuSWVersionMismatchFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Software Version Mismatch Fault. SW Versions on the Host and Remote do not match." ::= { fwuRmtSystemLevelTraps 22 } fwuDruSysCardFanFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Fan not functioning." ::= { fwuRmtSystemLevelTraps 23 } fwuDruOverTempFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DRU Temperature above operating limit." ::= { fwuRmtSystemLevelTraps 24 } fwuDruUnderTempFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DRU Temperature below operating limit." ::= { fwuRmtSystemLevelTraps 25 } fwuRmtSERFObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 2 } fwuRmtSERFInfo OBJECT IDENTIFIER ::= { fwuRmtSERFObjects 1 } fwuRmtSERFGeneral OBJECT IDENTIFIER ::= { fwuRmtSERFInfo 1 } fwuRmtSERFGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtSERFGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of remote SERF Card." ::= { fwuRmtSERFGeneral 1 } fwuRmtSERFGeneralEntry OBJECT-TYPE SYNTAX FwuRmtSERFGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to SERF Card objects." INDEX { fwuRmtNumber } ::= { fwuRmtSERFGeneralTable 1 } FwuRmtSERFGeneralEntry ::= SEQUENCE { fwuRmtSERFLinuxKernelVer DisplayString, fwuRmtSERFLinuxBootLoaderVer DisplayString, fwuRmtSERFCompactFlashSWVer DisplayString, fwuRmtSERFFPGAVer DisplayString, fwuRmtSERFPPCHWMonSWVer DisplayString, fwuRmtSERFPPCAPPMonSWVer DisplayString, --fwuRmtSERFPPCGPSMonSWVer DisplayString, --fwuRmtSERFPPCSNMPAgentSWVer DisplayString, fwuRmtSERFPPCMATEMonSWVer DisplayString, fwuRmtSERFPPCENETMonSWVer DisplayString, fwuRmtSERFPPCFPGAMonSWVer DisplayString, fwuRmtSERFRIDateCode DisplayString, fwuRmtSERFRIHWVer DisplayString, fwuRmtSERFRISerialNumber DisplayString, fwuRmtSERFRIADCPartNumber DisplayString, fwuRmtSERFRIHWGen INTEGER, fwuRmtpThreadSWVer DisplayString, fwuRmtWebServerSWVer DisplayString } fwuRmtSERFLinuxKernelVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Linux Kernel version on remote." ::= { fwuRmtSERFGeneralEntry 1 } fwuRmtSERFLinuxBootLoaderVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Linux Boot loader version on remote." ::= { fwuRmtSERFGeneralEntry 2 } fwuRmtSERFCompactFlashSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Compact Flash version on remote." ::= { fwuRmtSERFGeneralEntry 3 } fwuRmtSERFFPGAVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Version of FPGA loaded on remote SeRF." ::= { fwuRmtSERFGeneralEntry 4 } fwuRmtSERFPPCHWMonSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware monitor process version on remote." ::= { fwuRmtSERFGeneralEntry 5 } fwuRmtSERFPPCAPPMonSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Application monitor process version on remote." ::= { fwuRmtSERFGeneralEntry 6 } -- In Rel 6.0 this attribute is removed, as GPS is never supported. --fwuRmtSERFPPCGPSMonSWVer OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS deprecated -- DESCRIPTION "GPS monitor process Software Version of the remote system." -- ::= { fwuRmtSERFGeneralEntry 7 } --fwuRmtSERFPPCSNMPAgentSWVer OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION "SNMP agent version on remote." -- ::= { fwuRmtSERFGeneralEntry 8 } fwuRmtSERFPPCMATEMonSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Mate monitor process version on remote." ::= { fwuRmtSERFGeneralEntry 9 } fwuRmtSERFPPCENETMonSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "ENET monitor process version on remote." ::= { fwuRmtSERFGeneralEntry 10 } fwuRmtSERFPPCFPGAMonSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "FPGA monitor process version on remote." ::= { fwuRmtSERFGeneralEntry 11 } fwuRmtSERFRIDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote SERF Inventory - Date Code of the Remote system." ::= { fwuRmtSERFGeneralEntry 12 } fwuRmtSERFRIHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote SERF Inventory - HardWare version of the remote system." ::= { fwuRmtSERFGeneralEntry 13 } fwuRmtSERFRISerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote SERF Inventory - Serial Number." ::= { fwuRmtSERFGeneralEntry 14 } fwuRmtSERFRIADCPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote SERF Inventory - TE PartNumber." ::= { fwuRmtSERFGeneralEntry 15 } -- Rel 6.0 fwuRmtSERFRIHWGen OBJECT-TYPE SYNTAX INTEGER { firstGeneration(0), secondGeneration(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Remote SERF Hardware Generation. Presently, there are two generations first generation(0), second generation(1) " ::= { fwuRmtSERFGeneralEntry 16 } fwuRmtpThreadSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version number of pThread Process. If blank then pThread is not running." ::= { fwuRmtSERFGeneralEntry 17 } fwuRmtWebServerSWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version number of Web Server on remote." ::= { fwuRmtSERFGeneralEntry 18 } fwuRmtSERFOptObjects OBJECT IDENTIFIER ::= { fwuRmtSERFInfo 2 } fwuRmtSERFOptTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtSERFOptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of remote units SFP objects." ::= { fwuRmtSERFOptObjects 1 } fwuRmtSERFOptEntry OBJECT-TYPE SYNTAX FwuRmtSERFOptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to remote units SFP objects." INDEX { fwuRmtNumber, fwuRmtSERFOptSFPNumber } ::= { fwuRmtSERFOptTable 1 } FwuRmtSERFOptEntry ::= SEQUENCE { fwuRmtSERFOptSFPNumber Integer32, fwuRmtSERFOptSFPName DisplayString, fwuRmtSERFOptSFPType OPTICSType, fwuRmtSERFOptSFPColor Integer32, fwuRmtSERFOptRevLaunchPowerMeas DisplayString, fwuRmtSERFOptFwdLaunchPowerMeas DisplayString, fwuRmtSERFOptMateName DisplayString, fwuRmtSERFIPEnable INTEGER, fwuRmtSERFOptMateId UnitID2, fwuRmtSERFOptMateSfpId Integer32, fwuRmtSERFOptMateSfpDir INTEGER, fwuRmtSERFOptHostIP DisplayString } fwuRmtSERFOptSFPNumber OBJECT-TYPE SYNTAX Integer32 (1 .. 8) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of each SFP. The identifier is the SFP slot number. There are eight slots. Therefore, the valid values are 1 to 8." ::= { fwuRmtSERFOptEntry 1 } fwuRmtSERFOptSFPName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "User defined name of each Remote SFP. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters." DEFVAL { "SFP" } ::= { fwuRmtSERFOptEntry 2 } fwuRmtSERFOptSFPType OBJECT-TYPE SYNTAX OPTICSType MAX-ACCESS read-only STATUS current DESCRIPTION "SFP Type - Optical Port Type. Identifies whether the SFP is short(1)/intermediate(2)/long(3) range. It may also be unidentified (-1)." ::= { fwuRmtSERFOptEntry 3 } fwuRmtSERFOptSFPColor OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Wavelength of light used in the SFP (in nanometers)." ::= { fwuRmtSERFOptEntry 4 } fwuRmtSERFOptRevLaunchPowerMeas OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the optical power, in dBm received at the remote." ::= { fwuRmtSERFOptEntry 5 } fwuRmtSERFOptFwdLaunchPowerMeas OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Value of the optical power, in dBm transmitted by the remote." ::= { fwuRmtSERFOptEntry 6 } fwuRmtSERFOptMateName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of Remote mate." ::= { fwuRmtSERFOptEntry 7 } fwuRmtSERFIPEnable OBJECT-TYPE SYNTAX INTEGER { iPEnable(1), iPDisable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "IP enable mode." DEFVAL { 2 } ::= { fwuRmtSERFOptEntry 8 } fwuRmtSERFOptMateId OBJECT-TYPE SYNTAX UnitID2 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of (companion) mate unit." ::= { fwuRmtSERFOptEntry 9 } fwuRmtSERFOptMateSfpId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of SFP to which the mate connects." ::= { fwuRmtSERFOptEntry 10 } fwuRmtSERFOptMateSfpDir OBJECT-TYPE SYNTAX INTEGER { notDirection(-1) , reverse(0) , forwad(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the fiber is incoming(from the direction of the host) (0) or outgoing (away from the unit)(1) on this SFP port." ::= { fwuRmtSERFOptEntry 11 } fwuRmtSERFOptHostIP OBJECT-TYPE SYNTAX OCTET STRING ( SIZE (0..16) ) MAX-ACCESS read-only STATUS current DESCRIPTION "IP addresses of Host. If 'NA', then it means that no host is connected." DEFVAL { "NA" } ::= { fwuRmtSERFOptEntry 12 } fwuRmtSERFTraps OBJECT IDENTIFIER ::= { fwuRmtSERFObjects 2 } fwuRmtSERFHstLostFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host not communicating with DRU/PRU/URU." ::= { fwuRmtSERFTraps 2 } fwuRmtSERFOptRxBERFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "High bit error rate (BER) detected by fiber optic receiver." ::= { fwuRmtSERFTraps 3 } fwuRmtSERFOptRxNoLightFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "No signal detected by optical receiver." ::= { fwuRmtSERFTraps 4 } fwuRmtSERFOptLaserFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "SFP optical transmitter failed." ::= { fwuRmtSERFTraps 5 } fwuRmtSERFOptOverDriveFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "SFP optical receive input power above specification." ::= { fwuRmtSERFTraps 6 } fwuRmtSERFOptUnderDriveFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "SFP optical receive input power below specification." ::= { fwuRmtSERFTraps 7 } fwuRmtSERFSynthAlarmFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "SeRF synthesizer unlocked." ::= { fwuRmtSERFTraps 8 } fwuRmtSERFFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Summary of SeRF Synthesizer Unlocked alarm and SeRF FPGA status. Possibly, the system may not be communicating with the Ethernet Switch. This is also precipitated by the I2C Bus Fault." ::= { fwuRmtSERFTraps 9 } fwuRmtI2CBus1Fault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Indicates an I2C communication problem." ::= { fwuRmtSERFTraps 10 } fwuRmtI2CBus2Fault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Indicates an I2C communication problem." ::= { fwuRmtSERFTraps 11 } fwuRmtSERFEthPortObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 3 } fwuRmtSERFEthPortInfo OBJECT IDENTIFIER ::= { fwuRmtSERFEthPortObjects 1 } fwuRmtSERFEthPortTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtSERFEthPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains information of Host Ethernet Ports." ::= { fwuRmtSERFEthPortInfo 1 } fwuRmtSERFEthPortEntry OBJECT-TYPE SYNTAX FwuRmtSERFEthPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to Host SERF Ethernet port objects." INDEX { fwuRmtNumber, fwuRmtSERFEthPortNumber } ::= { fwuRmtSERFEthPortTable 1 } FwuRmtSERFEthPortEntry ::= SEQUENCE { fwuRmtSERFEthPortNumber Unsigned32, fwuRmtSERFEthPortType ENETType, fwuRmtSERFEthPortRxBytes Counter64, fwuRmtSERFEthPortRxPkts Counter64, fwuRmtSERFEthPortRxFcsErrors Counter64, fwuRmtSERFEthPortRxBroadcastPkts Counter64, fwuRmtSERFEthPortRxMulticastPkts Counter64, fwuRmtSERFEthPortRxFragmtdFrames Counter64, fwuRmtSERFEthPortRxJabbersFrames Counter64, fwuRmtSERFEthPortTxByteCounter Counter64, fwuRmtSERFEthPortTxPkts Counter64, fwuRmtSERFEthPortTxBroadcastPkts Counter64, fwuRmtSERFEthPortTxMulticastPkts Counter64, fwuRmtSERFEthPortSFPId Integer32 } fwuRmtSERFEthPortNumber OBJECT-TYPE SYNTAX Unsigned32 (1 .. 12) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier for each Ethernet port. There are twelve ports." ::= { fwuRmtSERFEthPortEntry 1 } fwuRmtSERFEthPortType OBJECT-TYPE SYNTAX ENETType MAX-ACCESS read-only STATUS current DESCRIPTION "An identifier for the type of Ethernet port. The port types are network(1), craft(2) , management(3) , switch(4) , SFP(5). It may be unknown (-1)." ::= { fwuRmtSERFEthPortEntry 2 } fwuRmtSERFEthPortRxBytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes recieved at this ethernet port." ::= { fwuRmtSERFEthPortEntry 3 } fwuRmtSERFEthPortRxPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets recieved at this ethernet port." ::= { fwuRmtSERFEthPortEntry 4 } fwuRmtSERFEthPortRxFcsErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of FCS errors recieved at this ethernet port." ::= { fwuRmtSERFEthPortEntry 5 } fwuRmtSERFEthPortRxBroadcastPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of broadcast packets recieved at this ethernet port." ::= { fwuRmtSERFEthPortEntry 6 } fwuRmtSERFEthPortRxMulticastPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of multicast packets recieved at this ethernet port." ::= { fwuRmtSERFEthPortEntry 7 } fwuRmtSERFEthPortRxFragmtdFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of fragmented frames received at this ethernet port." ::= { fwuRmtSERFEthPortEntry 8 } fwuRmtSERFEthPortRxJabbersFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of jabber frames received at this ethernet port." ::= { fwuRmtSERFEthPortEntry 9 } fwuRmtSERFEthPortTxByteCounter OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes transmitted from this ethernet port." ::= { fwuRmtSERFEthPortEntry 10 } fwuRmtSERFEthPortTxPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets transmitted from this ethernet port." ::= { fwuRmtSERFEthPortEntry 11 } fwuRmtSERFEthPortTxBroadcastPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of broadcast packets transmitted from this ethernet port." ::= { fwuRmtSERFEthPortEntry 12 } fwuRmtSERFEthPortTxMulticastPkts OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of multicast packets transmitted from this ethernet port." ::= { fwuRmtSERFEthPortEntry 13 } fwuRmtSERFEthPortSFPId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifier of SFP to which this ethernet port connects to." ::= { fwuRmtSERFEthPortEntry 14 } fwuRmtSERFEthPortTraps OBJECT IDENTIFIER ::= { fwuRmtSERFEthPortObjects 2 } fwuRmtSERFFPGAObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 4 } fwuRmtSERFFPGAInfo OBJECT IDENTIFIER ::= { fwuRmtSERFFPGAObjects 1 } fwuRmtSERFFPGAInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtSERFFPGAInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of remote SERF FPGA objects." ::= { fwuRmtSERFFPGAInfo 1 } fwuRmtSERFFPGAInfoEntry OBJECT-TYPE SYNTAX FwuRmtSERFFPGAInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to SERF FPGA information." INDEX { fwuRmtNumber } ::= { fwuRmtSERFFPGAInfoTable 1 } FwuRmtSERFFPGAInfoEntry ::= SEQUENCE { fwuRmtSERFFPGAStatus INTEGER } fwuRmtSERFFPGAStatus OBJECT-TYPE SYNTAX INTEGER { ppcCanTalkToFPGA(0) , ppcCannotTalkToFPGA(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Remote SERF Card FPGA status. Either the ppc can talk to FPGA(0) or not(1)" DEFVAL { 0 } ::= { fwuRmtSERFFPGAInfoEntry 1 } fwuRmtSERFFPGATraps OBJECT IDENTIFIER ::= { fwuRmtSERFFPGAObjects 2 } --fwuRmtMateMonObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 5 } --fwuRmtMateMonInfo OBJECT IDENTIFIER ::= { fwuRmtMateMonObjects 1 } --fwuRmtMateMonTable OBJECT-TYPE -- SYNTAX SEQUENCE OF FwuRmtMateMonEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION "This table maintains Information of Remote Mate Monitor." -- ::= { fwuRmtMateMonInfo 1 } --fwuRmtMateMonEntry OBJECT-TYPE -- SYNTAX FwuRmtMateMonEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION "Each entry in this table refers to remote Mate monitor objects." -- INDEX { fwuRMmonIndex } -- ::= { fwuRmtMateMonTable 1 } --FwuRmtMateMonEntry ::= SEQUENCE { -- fwuRMmonIndex Integer32, -- fwuRMmonHstIPAddress IpAddress, -- fwuRMmonHstID UnitType, -- fwuRMmonRmtID UnitID2 } -- --fwuRMmonIndex OBJECT-TYPE -- SYNTAX Integer32 (1..2147483647) -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION "Index of mate monitor table. " -- ::= { fwuRmtMateMonEntry 1 } -- --fwuRMmonHstIPAddress OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION "IP addresses of host mate." -- ::= { fwuRmtMateMonEntry 2 } -- --fwuRMmonHstID OBJECT-TYPE -- SYNTAX UnitType -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION "ID of companion host unit." -- ::= { fwuRmtMateMonEntry 3 } -- --fwuRMmonRmtID OBJECT-TYPE -- SYNTAX UnitID2 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION "ID of companion remote unit." -- ::= { fwuRmtMateMonEntry 4 } fwuRmtDARTObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 6 } fwuRmtDARTInfo OBJECT IDENTIFIER ::= { fwuRmtDARTObjects 1 } fwuRmtDARTGeneral OBJECT IDENTIFIER ::= { fwuRmtDARTInfo 1 } fwuRmtDARTGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtDARTGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of Remote DART Card." ::= { fwuRmtDARTGeneral 1 } fwuRmtDARTGeneralEntry OBJECT-TYPE SYNTAX FwuRmtDARTGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to remote DART Card objects." INDEX { fwuRmtNumber, fwuRmtDARTNumber } ::= { fwuRmtDARTGeneralTable 1 } FwuRmtDARTGeneralEntry ::= SEQUENCE { fwuRmtDARTNumber Integer32, fwuRmtDARTName DisplayString, fwuRmtDARTBandType BANDType, fwuRmtDARTPassBand OCTET STRING, fwuRmtDARTOperatingMode MODEType, fwuRmtDARTDiversityStatus INTEGER, fwuRmtDARTForwardGain GAINType, fwuRmtDARTReverseGain GAINType, fwuRmtDARTForwardDelay DELAYType, fwuRmtDARTReverseDelay DELAYType, fwuRmtDARTTempMeas DisplayString, fwuRmtDARTFPGAStatus INTEGER, fwuRmtDARTFPGAProgramVer DisplayString, fwuRmtDARTRIADCPartNumber DisplayString, fwuRmtDARTRISerialNumber DisplayString, fwuRmtDARTRIDateCode DisplayString, fwuRmtDARTRIHWVer DisplayString, fwuRmtDARTGeneralTableRowStatus RowStatus, fwuRmtDARTActualForwardDelay Integer32, fwuRmtDARTForwardLowerboundDelay Integer32, fwuRmtDARTForwardUpperboundDelay Integer32, fwuRmtDARTActualReverseDelay Integer32, fwuRmtDARTReverseLowerboundDelay Integer32, fwuRmtDARTReverseUpperboundDelay Integer32, fwuRmtDARTPeakInputPwrLvl1 DisplayString, fwuRmtDARTPeakInputPwrLvl2 DisplayString, fwuRmtDARTPeakAvgInputPwrLvl1 DisplayString, fwuRmtDARTPeakAvgInputPwrLvl2 DisplayString, fwuRmtDARTMinAvgInputPwrLvl1 DisplayString, fwuRmtDARTMinAvgInputPwrLvl2 DisplayString, fwuRmtDARTInputPowerMode INTEGER, fwuRmtDARTPwrLevelMaxHoldReset INTEGER, fwuRmtDARTLastMaxHoldResetTime OCTET STRING, fwuRmtDARTReverseGainMode INTEGER, fwuRmtDARTTxRIADCPartNumber DisplayString, fwuRmtDARTTxRISerialNumber DisplayString, fwuRmtDARTTxRIDateCode DisplayString, fwuRmtDARTTxRIHWVer DisplayString, fwuRmtDARTLinkedStatus INTEGER, fwuRmtDARTAvailable INTEGER, fwuRmtDARTUsedSFP INTEGER } fwuRmtDARTNumber OBJECT-TYPE SYNTAX Integer32 (1 .. 8) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier for each DART Card Object of remote. Since there are eight DART slots the valid values are 1 to 8." ::= { fwuRmtDARTGeneralEntry 1 } fwuRmtDARTName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "A user defined name for each DART Card object of remote. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 1 character. Maximum length of the name 64 characters." DEFVAL { "DART" } ::= { fwuRmtDARTGeneralEntry 2 } fwuRmtDARTBandType OBJECT-TYPE SYNTAX BANDType MAX-ACCESS read-only STATUS current DESCRIPTION "Band type of remote DART card." DEFVAL { -1 } ::= { fwuRmtDARTGeneralEntry 3 } fwuRmtDARTPassBand OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is for configuration of Pass-band type for Remote DART card. Following input formats are supported for Classic and SuperDart passband configuration. 1. For Classic Darts only, User input string would be enumeration value ( i.e., 'x'), ranging from 1 to 134. See below in section 3. for valid values. 2. For SuperDarts only, a. BandType_SubBand1+SubBand2 This is applicable only for contiguous passband selection, applicable only for PCS & AWS. (e.g., 'PCS_A1+A2+A3') b. BandType_SubBand1+SubBand2:SubBand5+SubBand6 This is applicable for noncontiguous passband selection, applicable only for PCS & AWS. (e.g., 'PCS_A1+A2:C2+C1') c. BandType_StartFrequency-StartFrequency This is applicable only for contiguous passband frequency range. (e.g.,, PCS_1930-1945) d. BandType_StartFrequency1-StartFrequency1:StartFrequency2-StartFrequency2 This is applicable only for noncontiguous passband frequency ranges. (e.g., PCS_1930-1940.5:1960.7-1970.6). Where BandType is 'PCS', 'AWS', 'UMTS','EGSM900','GSM1800', 'UC700'. 3. Valid enumeration value for classic dart:- undefined ( -1 ), cellularA2A(1),cellularA(2),cellularAA1A2(3),cellularA1(4), cellularB(5),cellularB1(6),cellularBB1(7), pcsA1(8),pcsA2(9),pcsA3(10),pcsB1(11),pcsB2(12),pcsB3(13), pcsC3(14),pcsC4(15),pcsC5(16),pcsD(17),pcsE(18),pcsF(19), pcsA1A2(24),pcsA2A3(25),pcsA3D(26),pcsDB1(27),pcsB1B2(28),pcsB2B3(29), pcsB3E(30),pcsEF(31),pcsFC3(32),pcsC3C4(33),pcsC4C5(34), pcsC5G(35),pcsGawsH(36),pcsFC2(37),pcsC1G(38),pcsA(39), pcsA2A3D(40),pcsA3DB1(41),pcsDB1B2(42),pcsB(43),pcsB2B3E(44), pcsB3EF(45),pcsEFC3(46),pcsFC3C4(47),pcsC(48), pcsC4C5G(49), pcsC5GawsH(50),pcsEFC2(51),pcsC1GawsH(52), pcsAD(53),pcsA2A3DB1(54),pcsA3DB1B2(55),pcsDB(56),pcsBE(57), pcsB2B3EF(58),pcsB3EFC3(59),pcsEFC3C4(60),pcsFC(61), pcsCG(62),pcsC4C5GawsH(63),pcsB3EFC2(64), pcsADB1(65),pcsA2A3DB1B2(66),pcsA3DB(67),pcsDBE(68), pcsBEF(69),pcsB2B3EFC3(70),pcsB3EFC3C4(71),pcsEFC(72), pcsFCG(73),pcsCGawsH(74),pcsB2B3EFC2(75), pcsADB1B2(76),pcsA2A3DB(77),pcsA3DBE(78),pcsDBEF(79), pcsBEFC3(80),pcsB2B3EFC3C4(81),pcsB3EFC(82), pcsEFCG(83),pcsFCGawsH(84),pcsADB(85), pcsA2A3DBE(86),pcsA3DBEF(87),pcsDBEFC3(88), pcsBEFC3C4(89),pcsB2B3EFC(90),pcsB3EFCG(91), pcsEFCGawsH(92),smrLow(93) , smrHigh( 94), awsA(95), awsAB(96), awsABC(97), awsABCD(98), awsABCDE(99), awsB(100), awsBC(101), awsBCD(102), awsBCDE(103), awsBCDEF(104), awsC(105), awsCD(106), awsCDE(107), awsCDEF(108), awsD(109), awsDE(110), awsDEF(111), awsE(112), awsEF(113), awsF(114), smrLowWide(115), cellularA2ABA1B1(116), GSM1800Low(117), GSM1800Middle(118), GSM1800High(119), umtsLow(120), umtsMiddle(121), umtsHigh(122), cellularAB(133), apac800iDEN(134) " DEFVAL { "-1" } ::= { fwuRmtDARTGeneralEntry 4 } fwuRmtDARTOperatingMode OBJECT-TYPE SYNTAX MODEType MAX-ACCESS read-create STATUS current DESCRIPTION "Operating mode of remote DART card. The DART may be operating normally (1) or on standby (2). The mode may be undefined (-1)." DEFVAL { 1 } ::= { fwuRmtDARTGeneralEntry 5 } fwuRmtDARTDiversityStatus OBJECT-TYPE SYNTAX INTEGER { nonDiversity(0), diversity(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Diversity Status of remote DART card." DEFVAL { 0 } ::= { fwuRmtDARTGeneralEntry 6 } fwuRmtDARTForwardGain OBJECT-TYPE SYNTAX GAINType MAX-ACCESS read-create STATUS current DESCRIPTION "Primary Gain in forward path of remote DART card. The range is 0-31dB with increments in steps of 1dB." DEFVAL { 0 } ::= { fwuRmtDARTGeneralEntry 7 } fwuRmtDARTReverseGain OBJECT-TYPE SYNTAX GAINType MAX-ACCESS read-only STATUS current DESCRIPTION "Primary Gain in reverse path of remote DART card." DEFVAL { 0 } ::= { fwuRmtDARTGeneralEntry 8 } fwuRmtDARTForwardDelay OBJECT-TYPE SYNTAX DELAYType MAX-ACCESS read-create STATUS current DESCRIPTION "Forward delay in micro seconds on the remote DART. If the delay setting is outside the valid range of delay values then ranging fault will be raised if the Remote Dart is Linked." ::= { fwuRmtDARTGeneralEntry 9 } fwuRmtDARTReverseDelay OBJECT-TYPE SYNTAX DELAYType MAX-ACCESS read-create STATUS current DESCRIPTION "Reverse delay in micro seconds on the remote DART. If the delay setting is outside the valid range of delay values then ranging fault will be raised if the Remote Dart is Linked." ::= { fwuRmtDARTGeneralEntry 10 } fwuRmtDARTTempMeas OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of Remote DART in degree Celsius." ::= { fwuRmtDARTGeneralEntry 11 } fwuRmtDARTFPGAStatus OBJECT-TYPE SYNTAX INTEGER { serfFpgaCanTalkToDARTFpga(0), serfFpgaCannotTalkToDARTFpga(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Remote DART FPGA Status. It indicates if the SERF FPGA can talk(0) or not talk(1)to DART FPGA ." ::= { fwuRmtDARTGeneralEntry 12 } fwuRmtDARTFPGAProgramVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "FPGA version on the remote DART." ::= { fwuRmtDARTGeneralEntry 13 } fwuRmtDARTRIADCPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote DART Inventory Data - TE Part Number." ::= { fwuRmtDARTGeneralEntry 14 } fwuRmtDARTRISerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote DART Inventory Data - Serial Number." ::= { fwuRmtDARTGeneralEntry 15 } fwuRmtDARTRIDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote DART Inventory Data - DateCode." ::= { fwuRmtDARTGeneralEntry 16 } fwuRmtDARTRIHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote DART Inventory Data - HW version." ::= { fwuRmtDARTGeneralEntry 17 } fwuRmtDARTGeneralTableRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row." ::= { fwuRmtDARTGeneralEntry 18 } fwuRmtDARTActualForwardDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the forward delay on Remote DART." ::= { fwuRmtDARTGeneralEntry 19 } fwuRmtDARTForwardLowerboundDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the lower bound of the Forward Delay values." ::= { fwuRmtDARTGeneralEntry 20 } fwuRmtDARTForwardUpperboundDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the upper bound of the Forward Delay values." ::= { fwuRmtDARTGeneralEntry 21 } fwuRmtDARTActualReverseDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the Reverse delay on Remote DART." ::= { fwuRmtDARTGeneralEntry 22 } fwuRmtDARTReverseLowerboundDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the lower bound of the Reverse delay values." ::= { fwuRmtDARTGeneralEntry 23 } fwuRmtDARTReverseUpperboundDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the upper bound of the Reverse delay values." ::= { fwuRmtDARTGeneralEntry 24 } fwuRmtDARTPeakInputPwrLvl1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Peak Input Power Level 1 to a Remote DART." ::= { fwuRmtDARTGeneralEntry 25 } fwuRmtDARTPeakInputPwrLvl2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Peak Input Power Level 2 to the Remote DART." ::= { fwuRmtDARTGeneralEntry 26 } fwuRmtDARTPeakAvgInputPwrLvl1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Peak Average Input Power Level 1 to the Remote DART." ::= { fwuRmtDARTGeneralEntry 27 } fwuRmtDARTPeakAvgInputPwrLvl2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Peak Average Input Power Level 2 to the Remote DART." ::= { fwuRmtDARTGeneralEntry 28 } fwuRmtDARTMinAvgInputPwrLvl1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum Average Input Power Level 1 to the Remote DART." ::= { fwuRmtDARTGeneralEntry 29 } fwuRmtDARTMinAvgInputPwrLvl2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum Average Input Power Level 2 to the Remote DART." ::= { fwuRmtDARTGeneralEntry 30 } fwuRmtDARTInputPowerMode OBJECT-TYPE SYNTAX INTEGER { snapShot(0), maxHold(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remote DART Input Power Level Mode. Two modes are supported Snapshot(0) and Max Hold(1)." DEFVAL { 0 } ::= { fwuRmtDARTGeneralEntry 31 } fwuRmtDARTPwrLevelMaxHoldReset OBJECT-TYPE SYNTAX INTEGER { notApplicable(-1), normal(0) , reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to reset the Max Hold reading. Used when the input power mode is Max hold. Reset by changing from normal (0) to reset (1). Status will revert to normal once the reset is done. In snapshot mode (see fwuRmtDARTInputPowerMode) this object is not applicable (-1)." DEFVAL { -1 } ::= { fwuRmtDARTGeneralEntry 32 } fwuRmtDARTLastMaxHoldResetTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Date and Time of the last maxHold reset on the remote DART." ::= { fwuRmtDARTGeneralEntry 33 } fwuRmtDARTReverseGainMode OBJECT-TYPE SYNTAX INTEGER { normal(0) , high(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The gain modes on the Reverse Path. Two modes are supported, Normal(0) and High(1). It is applicable to all RF modules but not to IF DARTs." DEFVAL { 0 } ::= { fwuRmtDARTGeneralEntry 34 } fwuRmtDARTTxRIADCPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Inventory Data - TE Part Number [Tx Board]. Field will have value only if Tx Board is present." ::= { fwuRmtDARTGeneralEntry 35 } fwuRmtDARTTxRISerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Inventory Data - Serial Number [Tx Board]. Field will have value only if Tx Board is present." ::= { fwuRmtDARTGeneralEntry 36 } fwuRmtDARTTxRIDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Inventory Data - DateCode [Tx Board]. Field will have value only if Tx Board is present." ::= { fwuRmtDARTGeneralEntry 37 } fwuRmtDARTTxRIHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Inventory Data - HW version [Tx Board]. Field will have value only if Tx Board is present." ::= { fwuRmtDARTGeneralEntry 38 } fwuRmtDARTLinkedStatus OBJECT-TYPE SYNTAX INTEGER { notLinked(0) , linked(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the DART is linked (1) or not (0)." ::= { fwuRmtDARTGeneralEntry 39 } fwuRmtDARTAvailable OBJECT-TYPE SYNTAX INTEGER { notAvailable(0) , available(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the DART is available for use (1) or not (0)." ::= { fwuRmtDARTGeneralEntry 40 } fwuRmtDARTUsedSFP OBJECT-TYPE SYNTAX INTEGER (1 .. 8) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the SFP (number) used by a DART to link. There are eight possible SFP numbers. Therefore, the valid values are 1 to 8." ::= { fwuRmtDARTGeneralEntry 41 } fwuRmtDARTTraps OBJECT IDENTIFIER ::= { fwuRmtDARTObjects 2 } fwuRmtDARTDwnCon1SynLockFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Lock state of the first down converter synthesizer." ::= { fwuRmtDARTTraps 2 } fwuRmtDARTDwnCon2SynLockFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DART downconverter 2 synthesizer unlocked." ::= { fwuRmtDARTTraps 3 } fwuRmtDARTUpConSynLockFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DART downconverter 2 synthesizer unlocked." ::= { fwuRmtDARTTraps 4 } fwuRmtDARTDCSupplyFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DART card DC supply voltages outside specification." ::= { fwuRmtDARTTraps 5 } fwuRmtDARTFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Summary of DART Downconverter 1 Synthesizer Unlocked, Downconverter 2 Synthesizer Unlocked, Upconverter Synthesizer Unlocked, DC Supply Fault alarms, and DART FPGA status." ::= { fwuRmtDARTTraps 6 } fwuRmtDARTHardwareMismatchFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Remote DART does not support the selected passband. Fault occurs when a Remote DART is replaced with another DART of the incorrect type." ::= { fwuRmtDARTTraps 7 } fwuRmtRangingFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "DRU/PRU/URU delay settings outside the valid range." ::= { fwuRmtDARTTraps 8 } fwuRmtDARTOverTempFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Remote DART temperature above operating limit." ::= { fwuRmtDARTTraps 9 } fwuRmtDARTLowTempFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Remote DART temperature below operating limit." ::= { fwuRmtDARTTraps 10 } fwuRmtDARTUplinkInactivityFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "No uplink activity is detected for one hour." ::= { fwuRmtDARTTraps 11 } fwuRmtDARTCommsFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "The Remote DART communication path is missing or incorrect." ::= { fwuRmtDARTTraps 12 } -- In Rel 6.0 this attribute is removed, as GPS is never supported. -- While modification take care of this OID. --fwuRmtGPSObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 7 } --fwuRmtGPSInfo OBJECT IDENTIFIER ::= { fwuRmtGPSObjects 1 } --fwuRmtGPSTraps OBJECT IDENTIFIER ::= { fwuRmtGPSObjects 2 } fwuRmtLPAObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 8 } fwuRmtLPAInfo OBJECT IDENTIFIER ::= { fwuRmtLPAObjects 1 } fwuRmtLPAInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtLPAInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of remote LPA objects." ::= { fwuRmtLPAInfo 1 } fwuRmtLPAInfoEntry OBJECT-TYPE SYNTAX FwuRmtLPAInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to LPA objects." INDEX { fwuRmtNumber, fwuRmtLPANumber } ::= { fwuRmtLPAInfoTable 1 } FwuRmtLPAInfoEntry ::= SEQUENCE { fwuRmtLPANumber Integer32, fwuRmtLPAReset INTEGER, fwuRmtLPAOpState INTEGER, fwuRmtLPAPartNum DisplayString, fwuRmtLPASerialNum DisplayString, fwuRmtLPAHWVer DisplayString, fwuRmtLPASWVer DisplayString, fwuRmtLPADescr DisplayString, fwuRmtLPAControl INTEGER, fwuRmtLPAMaxOpPwr DisplayString, fwuRmtLPABandType DuplexerType } fwuRmtLPANumber OBJECT-TYPE SYNTAX Integer32 (1 .. 4) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier for an LPA." ::= { fwuRmtLPAInfoEntry 1 } fwuRmtLPAReset OBJECT-TYPE SYNTAX INTEGER { normal(0) , reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to reset the LPA. Change from normal(0) to reset(1) to perform a reset of the LPA. Resetting the LPA when it is offline will place in an operating state." DEFVAL { 0 } ::= { fwuRmtLPAInfoEntry 2 } fwuRmtLPAOpState OBJECT-TYPE SYNTAX INTEGER { operating(0) , offline(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the LPA Operating mode. The modes are operating (0) and offline (1). The operating state is controlled by fwuRmtLPAControl. Also, see fwuRmtLPAReset." DEFVAL { 1 } ::= { fwuRmtLPAInfoEntry 3 } fwuRmtLPAPartNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote LPA Part Number." ::= { fwuRmtLPAInfoEntry 4 } fwuRmtLPASerialNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote LPA Serial Number." ::= { fwuRmtLPAInfoEntry 5 } fwuRmtLPAHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote LPA Hardware version." ::= { fwuRmtLPAInfoEntry 6 } fwuRmtLPASWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote LPA Software version." ::= { fwuRmtLPAInfoEntry 7 } fwuRmtLPADescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote LPA Description." ::= { fwuRmtLPAInfoEntry 8 } fwuRmtLPAControl OBJECT-TYPE SYNTAX INTEGER { normal(0), standby(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to control the operating mode of remote LPA. When the control is set to normal (0), the operating mode is operating. When the control is set to offline (1), the operating mode is standby. fwuRmtLPAOpState will reflect the change in state/mode when the values are changed for this entity." DEFVAL { 1 } ::= { fwuRmtLPAInfoEntry 9 } fwuRmtLPAMaxOpPwr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum Output power for the LPA. This object is applicable for HDMs also." ::= { fwuRmtLPAInfoEntry 10 } fwuRmtLPABandType OBJECT-TYPE SYNTAX DuplexerType MAX-ACCESS read-only STATUS current DESCRIPTION " LPA hardware type. Valid LPA Types are cellularA(1), cellularB(2), smrLow(3), smrHigh(4), pcs(5), aws(6), smrLowWide(7), fullCellular(8), gsm1800(9), umts(10), egsm900(11), lowerABC(12), upperC700(13), apac800iDEN(14), prismSmr800and900(15), prismSmr900and800(16), prismSmr800(17), cellularApac(18), apacEgsm900(19), pGsmEgsm900(20) " ::= { fwuRmtLPAInfoEntry 11 } fwuRmtLPATraps OBJECT IDENTIFIER ::= { fwuRmtLPAObjects 2 } fwuRmtLPADisableFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "PRU/URU Linear Power Amplifier (LPA) disabled due to an internally detected problem. (VSWR, DC, Loop Fault, Low Power, or Temperature High alarm)." ::= { fwuRmtLPATraps 2 } fwuRmtLPAOverPowerFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "PRU/URU Linear Power Amplifier (LPA) output power level above operating limit." ::= { fwuRmtLPATraps 3 } fwuRmtLPAHighTempFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "LPA High Temperature Fault." ::= { fwuRmtLPATraps 4 } fwuRmtLPAVswrFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "PRU/URU Linear Power Amplifier (LPA) VSWR fault." ::= { fwuRmtLPATraps 5 } fwuRmtLPADcFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "PRU/URU Linear Power Amplifier (LPA) DC fault." ::= { fwuRmtLPATraps 6 } fwuRmtLPALoopFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "PRU/URU Linear Power Amplifier (LPA) Loop fault." ::= { fwuRmtLPATraps 7 } fwuRmtLPALowPowerFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Internal low power fault state of linear power amplifier (the gain of one or more internal amplifiers does not meet specification)." ::= { fwuRmtLPATraps 8 } fwuRmtLPADetectFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Linear Power Amplifier (LPA) detection fault. LPA missing from remote." ::= { fwuRmtLPATraps 9 } fwuRmtPaOverCurrentFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "PA reported fault." ::= { fwuRmtLPATraps 10 } fwuRmtPwrDetectorBoardObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 9 } fwuRmtPwrDetectorBoardInfo OBJECT IDENTIFIER ::= { fwuRmtPwrDetectorBoardObjects 1 } fwuRmtPwrDetectorBoardInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtPwrDetectorBoardInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of remote power detector board objects." ::= { fwuRmtPwrDetectorBoardInfo 1 } fwuRmtPwrDetectorBoardInfoEntry OBJECT-TYPE SYNTAX FwuRmtPwrDetectorBoardInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to power detector board objects." INDEX { fwuRmtNumber,fwuRmtPowerDetectorNumber } ::= { fwuRmtPwrDetectorBoardInfoTable 1 } FwuRmtPwrDetectorBoardInfoEntry ::= SEQUENCE { fwuRmtPowerDetectorNumber Integer32, fwuRmtSystemVswrMeas DisplayString, fwuRmtRFPowerOutputMeas DisplayString, fwuRmtPwrDetectorBoardRIADCPartNum DisplayString, fwuRmtPwrDetectorBoardRISerialNum DisplayString, fwuRmtPwrDetectorBoardRIDateCode DisplayString, fwuRmtPwrDetectorBoardRIHWVer DisplayString, fwuRmtPwrDetectorNoRfPowerThershold DisplayString, fwuRmtSystemVSWRThreshold DisplayString } fwuRmtPowerDetectorNumber OBJECT-TYPE SYNTAX Integer32 (1.. 4) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier for each power detector." ::= { fwuRmtPwrDetectorBoardInfoEntry 1 } fwuRmtSystemVswrMeas OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "VSWR (Voltage Standing Wave Ratio) measured in the system." ::= { fwuRmtPwrDetectorBoardInfoEntry 2 } fwuRmtRFPowerOutputMeas OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The value of Remote RF Power Output, in dBm." ::= { fwuRmtPwrDetectorBoardInfoEntry 3 } fwuRmtPwrDetectorBoardRIADCPartNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Power Detector Inventory - TE Part Number." ::= { fwuRmtPwrDetectorBoardInfoEntry 4 } fwuRmtPwrDetectorBoardRISerialNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Power Detector Inventory - Serial Number." ::= { fwuRmtPwrDetectorBoardInfoEntry 5 } fwuRmtPwrDetectorBoardRIDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Power Detector Inventory - Date Code." ::= { fwuRmtPwrDetectorBoardInfoEntry 6 } fwuRmtPwrDetectorBoardRIHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Power Detector Inventory - HW version." ::= { fwuRmtPwrDetectorBoardInfoEntry 7 } fwuRmtPwrDetectorNoRfPowerThershold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Threshold value for RF No Power. The minimum threshold value is 0dBm and maximum threshold value is 100dBm." ::= { fwuRmtPwrDetectorBoardInfoEntry 8 } fwuRmtSystemVSWRThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "User set VSWR threshold value. User is to provide the VSWR value in the form x.y:1. If the value is provided as x:1 then it will be represented as x.0:1. The minimum threshold value is 2.0 and maximum threshold value is 9.0." ::= { fwuRmtPwrDetectorBoardInfoEntry 9 } fwuRmtPwrDetectorBoardTraps OBJECT IDENTIFIER ::= { fwuRmtPwrDetectorBoardObjects 2 } fwuRmtSystemVswrFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "PRU/URU VSWR measurement above specification." ::= { fwuRmtPwrDetectorBoardTraps 2 } fwuRmtRFPowerFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "PRU/URU RF Output Power below minimum threshold." ::= { fwuRmtPwrDetectorBoardTraps 3 } fwuRmtLNAObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 10 } fwuRmtLNAInfo OBJECT IDENTIFIER ::= { fwuRmtLNAObjects 1 } fwuRmtLNAInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtLNAInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of remote LNA objects." ::= { fwuRmtLNAInfo 1 } fwuRmtLNAInfoEntry OBJECT-TYPE SYNTAX FwuRmtLNAInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to LNA information." INDEX { fwuRmtNumber, fwuRmtLNANumber } ::= { fwuRmtLNAInfoTable 1 } FwuRmtLNAInfoEntry ::= SEQUENCE { fwuRmtLNANumber Integer32, fwuRmtLNAType LNAType, fwuRmtLNARIADCPartNumber DisplayString, fwuRmtLNARISerialNumber DisplayString, fwuRmtLNARIDateCode DisplayString, fwuRmtLNARIHWVer DisplayString, fwuRmtDuplexerType DuplexerType } fwuRmtLNANumber OBJECT-TYPE SYNTAX Integer32 (1 .. 8) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier for LNA Objects." ::= { fwuRmtLNAInfoEntry 1 } fwuRmtLNAType OBJECT-TYPE SYNTAX LNAType MAX-ACCESS read-only STATUS current DESCRIPTION "Remote LNA card type. Valid LNA types are Cellular A(1), Cellular B(2), SMR Low(3), SMR High(4), PCS(5), AWS(6), SMR Low Wide(7), Full Cellular(8), GSM1800(9), UMTS(10), EGSM900(11), Lower ABC 700(12), Upper C 700(13), APAC 800 iDEN(14), Prism SMR 800 and 900(15), Prism SMR 900 and 800(16), Prism SMR 800(17)." ::= { fwuRmtLNAInfoEntry 2 } fwuRmtLNARIADCPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LNA Inventory Data - TE Part Number." ::= { fwuRmtLNAInfoEntry 3 } fwuRmtLNARISerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LNA Inventory Data - Serial Number." ::= { fwuRmtLNAInfoEntry 4 } fwuRmtLNARIDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LNA Inventory Data - Date Code." ::= { fwuRmtLNAInfoEntry 5 } fwuRmtLNARIHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LNA Inventory Data - HW version." ::= { fwuRmtLNAInfoEntry 6 } fwuRmtDuplexerType OBJECT-TYPE SYNTAX DuplexerType MAX-ACCESS read-only STATUS current DESCRIPTION " Duplexer hardware type. Valid Duplexer Types are cellularA(1), cellularB(2), smrLow(3), smrHigh(4), pcs(5), aws(6), smrLowWide(7), fullCellular(8), gsm1800(9), umts(10), egsm900(11), lowerABC(12), upperC700(13), apac800iDEN(14), prismSmr800and900(15), prismSmr900and800(16), prismSmr800(17), cellularApac(18), apacEgsm900(19), pGsmEgsm900(20) " ::= { fwuRmtLNAInfoEntry 7 } fwuRmtLNATraps OBJECT IDENTIFIER ::= { fwuRmtLNAObjects 2 } fwuRmtLNAPowerFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "PRU/URU Low Noise Amplifier (LNA) Power fault." ::= { fwuRmtLNATraps 2 } fwuRmtDuplexerFreqMismatchFault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Configured frequency range not supported by Duplexer." ::= { fwuRmtLNATraps 3 } fwuRmtRDIObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 11 } fwuRmtRDIInfo OBJECT IDENTIFIER ::= { fwuRmtRDIObjects 1 } fwuRmtRDIInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtRDIInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of remote RDI objects." ::= { fwuRmtRDIInfo 1 } fwuRmtRDIInfoEntry OBJECT-TYPE SYNTAX FwuRmtRDIInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to RDI information." INDEX { fwuRmtNumber, fwuRmtRDINumber } ::= { fwuRmtRDIInfoTable 1 } FwuRmtRDIInfoEntry ::= SEQUENCE { fwuRmtRDINumber Integer32, fwuRmtRDIRIADCPartNumber DisplayString, fwuRmtRDIRISerialNumber DisplayString, fwuRmtRDIRIDateCode DisplayString, fwuRmtRDIRIHWVer DisplayString, fwuRmtRDIRIHWType INTEGER } fwuRmtRDINumber OBJECT-TYPE SYNTAX Integer32 (1 .. 4) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier for each RDI." ::= { fwuRmtRDIInfoEntry 1 } fwuRmtRDIRIADCPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RDI Inventory Data - TE Part Number." ::= { fwuRmtRDIInfoEntry 2 } fwuRmtRDIRISerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RDI Inventory Data - Serial Number." ::= { fwuRmtRDIInfoEntry 3 } fwuRmtRDIRIDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RDI Inventory Data - Date Code." ::= { fwuRmtRDIInfoEntry 4 } fwuRmtRDIRIHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RDI Inventory Data - HW version." ::= { fwuRmtRDIInfoEntry 5 } fwuRmtRDIRIHWType OBJECT-TYPE SYNTAX INTEGER { unknown(0), rdi(1), alpaca(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies if RDI(1) or ALPACA(2) board. It may be unknown(0)." DEFVAL { 0 } ::= { fwuRmtRDIInfoEntry 6 } fwuRmtRDITraps OBJECT IDENTIFIER ::= { fwuRmtRDIObjects 2 } fwuRmtACPowerSupplyMon1Fault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "AC Power monitor 1 Fault." ::= { fwuRmtRDITraps 1 } fwuRmtACPowerSupplyMon2Fault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "AC Power monitor 2 Fault." ::= { fwuRmtRDITraps 2 } fwuRmtACPowerSupplyMon3Fault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "AC Power monitor 3 Fault." ::= { fwuRmtRDITraps 3 } fwuRmtRSIObjects OBJECT IDENTIFIER ::= { fwuRemoteUnitObjects 12 } fwuRmtRSIInfo OBJECT IDENTIFIER ::= { fwuRmtRSIObjects 1 } fwuRmtRSIInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuRmtRSIInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of Remote RSI objects." ::= { fwuRmtRSIInfo 1 } fwuRmtRSIInfoEntry OBJECT-TYPE SYNTAX FwuRmtRSIInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to RSI information." INDEX { fwuRmtNumber } ::= { fwuRmtRSIInfoTable 1 } FwuRmtRSIInfoEntry ::= SEQUENCE { fwuRmtRSIRIADCPartNumber DisplayString, fwuRmtRSIRISerialNumber DisplayString, fwuRmtRSIRIDateCode DisplayString, fwuRmtRSIRIHWVer DisplayString, fwuRmtCapacity Unsigned32 } fwuRmtRSIRIADCPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Inventory Data - TE Part Number." ::= { fwuRmtRSIInfoEntry 1 } fwuRmtRSIRISerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Inventory Data - Serial Number." ::= { fwuRmtRSIInfoEntry 2 } fwuRmtRSIRIDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Inventory Data - Date Code." ::= { fwuRmtRSIInfoEntry 3 } fwuRmtRSIRIHWVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Inventory Data - Hardware version." ::= { fwuRmtRSIInfoEntry 4 } fwuRmtCapacity OBJECT-TYPE SYNTAX Unsigned32(1 .. 4) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RF modules that can be installed in the remote." ::= { fwuRmtRSIInfoEntry 5 } fwuRmtRSITraps OBJECT IDENTIFIER ::= { fwuRmtRSIObjects 2 } fwuRmtACPowerSupplyMon4Fault NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "AC Power monitor 4 Fault." ::= { fwuRmtRSITraps 1 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Dart Mapping Table Objects (.15.2.1.3.2) -- -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuDARTMappingObjects OBJECT IDENTIFIER ::= { fwuGeneralObjects 2 } fwuDARTMappingInfo OBJECT IDENTIFIER ::= { fwuDARTMappingObjects 1 } fwuDARTMappingTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuDARTMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of DART Mapping Objects." ::= { fwuDARTMappingInfo 1 } fwuDARTMappingEntry OBJECT-TYPE SYNTAX FwuDARTMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to DART Mapping Objects." INDEX { fwuDARTMappingIndex } ::= { fwuDARTMappingTable 1 } FwuDARTMappingEntry ::= SEQUENCE { fwuDARTMappingIndex Unsigned32, fwuUnitID UnitID2, fwuUnitDARTID Integer32, fwuUnitSFPID Integer32 , fwuUnitDartPassBand OCTET STRING, fwuMateID UnitID2, fwuMateDARTID Integer32, fwuMateSFPID Integer32, fwuMateDartPassband OCTET STRING, fwuSFPStartTimeSlot Integer32, fwuSFPEndTimeSlot Integer32, fwuMappingStatus RowStatus } fwuDARTMappingIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "DART Mapping Table Index." ::= { fwuDARTMappingEntry 1 } fwuUnitID OBJECT-TYPE SYNTAX UnitID2 MAX-ACCESS read-create STATUS current DESCRIPTION "Identifier for the unit." ::= { fwuDARTMappingEntry 2 } fwuUnitDARTID OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-create STATUS current DESCRIPTION "Identifier of DART on the unit. Since there is a maximum of 8 DARTs, the valid values are one to eight." ::= { fwuDARTMappingEntry 3 } fwuUnitSFPID OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-create STATUS current DESCRIPTION "Identifier of unit SFP connected to the mate DART (outgoing; away from the Host). Since there is a maximum of 8 SFPs, the valid values are one to eight." ::= { fwuDARTMappingEntry 4 } fwuUnitDartPassBand OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Band-Passband information of the linked DART on the host side." ::= { fwuDARTMappingEntry 5 } fwuMateID OBJECT-TYPE SYNTAX UnitID2 MAX-ACCESS read-create STATUS current DESCRIPTION "Identifier of (companion) mate unit." ::= { fwuDARTMappingEntry 6 } fwuMateDARTID OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-create STATUS current DESCRIPTION "Identifies the (companion) DART on mate unit. Since there is a maximum of 8 DARTs, the valid values are one to eight." ::= { fwuDARTMappingEntry 7 } fwuMateSFPID OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-create STATUS current DESCRIPTION "Identifies the remote SFP connected to the unit DART(incoming from direction of the Host)." ::= { fwuDARTMappingEntry 8 } fwuMateDartPassband OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "Band-Passband information of the linked DART on the Mate side." ::= { fwuDARTMappingEntry 9 } fwuSFPStartTimeSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Value of the first time slot used on the fiber carrying RF from unit DART to mate DART. Though this is a read-write object, the end user can only read the value. This and the next object are pair of values for a fiber. Depending on the DART type there may be a maximum of six or twelve time slots." ::= { fwuDARTMappingEntry 10 } fwuSFPEndTimeSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Value of the last time slot used on the fiber carrying RF from unit DART to mate DART. Though this is a read-write object, the end user can only read the value. This and the previous object are pair of values for a fiber." ::= { fwuDARTMappingEntry 11 } fwuMappingStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the conceptual row. The status may be active or inactive." ::= { fwuDARTMappingEntry 12 } fwuSystemAlarmManagement OBJECT IDENTIFIER ::= { fwuGeneralObjects 3 } fwuSystemAlarmManagementTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuSystemAlarmManagementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains alarm managing property and threshold information of all alarms." ::= { fwuSystemAlarmManagement 1 } fwuSystemAlarmManagementEntry OBJECT-TYPE SYNTAX FwuSystemAlarmManagementEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to Alarm management table Objects." INDEX { fwuSystemAlarmcode} ::= { fwuSystemAlarmManagementTable 1 } FwuSystemAlarmManagementEntry ::= SEQUENCE { fwuSystemAlarmcode Unsigned32, fwuSystemAlarmManageable ALARMManage, fwuSystemAlarmThreshold DisplayString, fwuSystemAlarmModType Integer32 } fwuSystemAlarmcode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm code.It is used as Table Index." ::= { fwuSystemAlarmManagementEntry 1 } fwuSystemAlarmManageable OBJECT-TYPE SYNTAX ALARMManage MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if the alarm is manageble(0) or not (1). If manageable, use fwuSystemAlarmEnabled, see below, to enable or disable the alarm." ::= { fwuSystemAlarmManagementEntry 2 } fwuSystemAlarmThreshold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm Threshold value." ::= { fwuSystemAlarmManagementEntry 3 } fwuSystemAlarmModType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Identifies the module type which raised the alarm." ::= { fwuSystemAlarmManagementEntry 4 } fwuSystemModuleAlarmEnableTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuSystemModuleAlarmEnableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table will allow the user to enable or disable an alarm. Use the fwuSystemAlarmManagementTable to check if the alarm is manageable or not." ::= { fwuSystemAlarmManagement 2 } fwuSystemModuleAlarmEnableEntry OBJECT-TYPE SYNTAX FwuSystemModuleAlarmEnableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to Module alarm enable table Objects." INDEX { fwuSystemTrapNodeAddress,fwuSystemAlarmModuleNo,fwuSystemModuleAlarmcode } ::= { fwuSystemModuleAlarmEnableTable 1 } FwuSystemModuleAlarmEnableEntry ::= SEQUENCE { fwuSystemTrapNodeAddress Unsigned32, fwuSystemAlarmModuleNo Unsigned32, fwuSystemModuleAlarmcode Unsigned32, fwuSystemAlarmEnabled ALARMEnable } fwuSystemTrapNodeAddress OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The unit which raised the alarm." ::= { fwuSystemModuleAlarmEnableEntry 1 } fwuSystemAlarmModuleNo OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The module which raised the alarm." ::= { fwuSystemModuleAlarmEnableEntry 2 } fwuSystemModuleAlarmcode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The alarm code." ::= { fwuSystemModuleAlarmEnableEntry 3 } fwuSystemAlarmEnabled OBJECT-TYPE SYNTAX ALARMEnable MAX-ACCESS read-write STATUS current DESCRIPTION "This is used to enable or disable the alarm. Alarms is enabled by default, except the Uplink inactivity fault." ::= { fwuSystemModuleAlarmEnableEntry 4 } fwuGeoObjects OBJECT IDENTIFIER ::= { fwuGeneralObjects 4 } --fwuGeoHeartbeatTimer OBJECT-TYPE -- SYNTAX Integer32 (1..30) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Heartbeat can be sent at the timer specified here." -- DEFVAL { 20 } -- ::= { fwuGeoObjects 1 } fwuGeoTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuGeoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table maintains Information of Geo Objects." ::= { fwuGeoObjects 2 } fwuGeoEntry OBJECT-TYPE SYNTAX FwuGeoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry in this table refers to Geo Objects." INDEX { fwuGeoIndex } ::= { fwuGeoTable 1 } FwuGeoEntry ::= SEQUENCE { fwuGeoIndex Unsigned32, fwuGeoLatitude DisplayString, fwuGeoLongitude DisplayString, fwuGeoRmtName DisplayString, fwuGeoStatus INTEGER } fwuGeoIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Geo objects Table Index." ::= { fwuGeoEntry 1 } fwuGeoLatitude OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Identifies the Latitude of remote unit." ::= { fwuGeoEntry 2 } fwuGeoLongitude OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Identifies the Longitude of remote unit." ::= { fwuGeoEntry 3 } fwuGeoRmtName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Remote name." ::= { fwuGeoEntry 4 } fwuGeoStatus OBJECT-TYPE SYNTAX INTEGER { notPresent(0), active(1), inActive(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Standard SNMP row status for this table." ::= { fwuGeoEntry 5 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- SNMP Specific parameters [Rev-7] (.15.2.1.3.5) -- fwuSnmpSettings OBJECT IDENTIFIER::= {fwuGeneralObjects 5} -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuV1TrapAgentAddrOverrideMode OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to overide the default (1) or use default (0) agent address in v1 trap PDU. Use fwuV1TrapAgentAddrOverrideIPAddr to set the overriding agent address." DEFVAL { 0 } ::= { fwuSnmpSettings 1 } fwuV1TrapAgentAddrOverrideIPAddr OBJECT-TYPE SYNTAX OCTET STRING ( SIZE (0..16) ) MAX-ACCESS read-write STATUS current DESCRIPTION "The overriding agent IP address in v1 trap PDU. Use Internet standard dot-decimal notation. Enable its use by setting fwuV1TrapAgentAddrOverrideMode." ::= { fwuSnmpSettings 2 } fwuSnmpTrapResendInterval OBJECT-TYPE SYNTAX Integer32 (0..600) MAX-ACCESS read-write STATUS current DESCRIPTION "Time, in seconds, to resend unacknowledged traps. The trap will not be resent if this is set to zero(0). Acknowledgement is not needed if resend is not required, therefore, no trap entry will be entered into fwuSystemActiveAlarmTable." DEFVAL { 0 } ::= { fwuSnmpSettings 3 } fwuSnmpTrapResendMaximum OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum number of times traps will be resent before removal if not acknowledged. If set to zero, it will not be resent." DEFVAL { 2 } ::= { fwuSnmpSettings 4 } --fwuImAliveTrapInterval OBJECT-TYPE -- SYNTAX Integer32 (-86400..-1 | 0 | 1..60) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "This is the time interval for sending I'm Alive traps. If the number (T) is -- less than 0, then the interval is abs(T) seconds. If the number is greater -- than 0, then the interval is (T) days. If the number is 0, it will stop sending -- the I'm Alive traps. No acknowledgement is required." -- ::= { fwuSnmpSettings 5 } --fwuEthernetModemWakeUp OBJECT-TYPE -- SYNTAX INTEGER { false(0), true(1)} -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "To send a wake up to external modem if used." -- ::= { fwuSnmpSettings 6 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Snmp Trap Dest Table [Rev-7] (.15.2.1.3.5.7) -- -- Rearranged the OIDs in order to minimize MIB compatibility issues -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuSnmpTrapMgrConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuSnmpTrapMgrConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table containing information about the trap destinations. For changes to take effect, a (Host) reboot is required." ::= { fwuSnmpSettings 7} fwuSnmpTrapMgrConfigEntry OBJECT-TYPE SYNTAX FwuSnmpTrapMgrConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the fwuSnmpTrapMgrConfigTable." INDEX { fwuTrapMgrRowId } ::= { fwuSnmpTrapMgrConfigTable 1 } FwuSnmpTrapMgrConfigEntry ::= SEQUENCE { fwuTrapMgrRowId INTEGER, fwuTrapMgrIpAddress OCTET STRING, fwuTrapMgrListeningPort Unsigned32, fwuTrapMgrCommunity DisplayString, fwuTrapVersion INTEGER, fwuTrapMgrRowStatus RowStatus } fwuTrapMgrRowId OBJECT-TYPE SYNTAX INTEGER (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The unique index of this trap destination." ::= {fwuSnmpTrapMgrConfigEntry 1} fwuTrapMgrIpAddress OBJECT-TYPE SYNTAX OCTET STRING ( SIZE (0..16) ) MAX-ACCESS read-create STATUS current DESCRIPTION "Provision to set the IP address of the trap manager. Use Internet standard dot-decimal notation." DEFVAL { "127.0.0.1" } ::= {fwuSnmpTrapMgrConfigEntry 2} fwuTrapMgrListeningPort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Provision to set the port at which the trap manager is listening for the traps. The default port for SNMP traps is 162." DEFVAL { 162 } ::= {fwuSnmpTrapMgrConfigEntry 3} fwuTrapMgrCommunity OBJECT-TYPE SYNTAX DisplayString ( SIZE(6..20)) MAX-ACCESS read-create STATUS current DESCRIPTION "The community used by the agent to send traps or informs to this manager." DEFVAL { "public" } ::= { fwuSnmpTrapMgrConfigEntry 4 } fwuTrapVersion OBJECT-TYPE SYNTAX INTEGER { v1(0), v2c(1), inform(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The SNMP version used for this trap destination. The available versions are v1(0), v2c(1), inform(2) with v2c being set as default." DEFVAL { 1 } ::= {fwuSnmpTrapMgrConfigEntry 5} fwuTrapMgrRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. This is used to manage the creation and deletion of this trap destination table." DEFVAL { notInService } ::= {fwuSnmpTrapMgrConfigEntry 6} fwuEnableNotifHysteresis OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to enable(1) or disable(0) event hysteresis. If disabled notification is sent out on occurance of the event. If enabled set the hysteresis value using fwuEventNotifHysteresis." DEFVAL { 0 } ::= { fwuSnmpSettings 8 } fwuEventNotifHysteresis OBJECT-TYPE SYNTAX Integer32 (10..600) MAX-ACCESS read-write STATUS current DESCRIPTION "Time period, in seconds, for which an event has to persist before a notification is sent. For this value to be useable, ensure that fwuEnableNotifHysteresis is enabled." ::= { fwuSnmpSettings 9 } fwuEnableNotifInterval OBJECT-TYPE SYNTAX INTEGER {disable(0), enable(1)} MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to enable(1) or disable(0) a time lag before sending out an event notification. If disabled, notification is sent out on the occurance of the event. If enabled, use fwuEventNotifInterval to set the lag." DEFVAL { 0 } ::= { fwuSnmpSettings 10 } fwuEventNotifInterval OBJECT-TYPE SYNTAX Integer32 (5..60) MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to set the time lag in seconds between the successive event notifications. For this value to be useable, ensure that fwuEnableNotifInterval is enabled." ::= { fwuSnmpSettings 11 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Scheduler Table objects (.15.2.1.3.5.12) -- -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuSchedulerTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuSchedulerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table containing information about the trap destinations. For changes to take effect, a (Host) reboot is required." ::= { fwuSnmpSettings 12} fwuSchedulerEntry OBJECT-TYPE SYNTAX FwuSchedulerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the fwuSchedulerTable." INDEX { fwuTaskId } ::= { fwuSchedulerTable 1 } FwuSchedulerEntry ::= SEQUENCE { fwuTaskId INTEGER, fwuTaskType INTEGER, fwuScheduleStatus INTEGER, fwuTaskStartTime DisplayString, fwuOccurrences INTEGER, fwuRecurrence DisplayString, fwuFunctionArgs DisplayString, fwuRowStatus RowStatus} fwuTaskId OBJECT-TYPE SYNTAX INTEGER (0 .. 2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The unique index of the Scheduler table. Range limited to machine integer size(32 bit) restriction." ::= {fwuSchedulerEntry 1} fwuTaskType OBJECT-TYPE SYNTAX INTEGER { systemTest(2), iamAliveTrap(5) } MAX-ACCESS read-create STATUS current DESCRIPTION "The task to be scheduled. If System Test is the task being scheduled it requires some more arguments. Use fwuFunctionArgs to provide them. After specifying a task, enable the task using fwuScheduleStatus." ::= {fwuSchedulerEntry 2} fwuScheduleStatus OBJECT-TYPE SYNTAX INTEGER { notEnabled(0), enabled(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "Provision to enable(1) or disable(0) the scheduled task (defined by fwuTaskType)." DEFVAL { 0 } ::= {fwuSchedulerEntry 3} fwuTaskStartTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The start time of the scheduled activity." ::= {fwuSchedulerEntry 4} fwuOccurrences OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "Provision to set the number of times the task is to be executed. Set a value greater than 0 for a finite number of executions. To keep executing forever, set value to -1." DEFVAL { -1 } ::= {fwuSchedulerEntry 5} fwuRecurrence OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Provision to set the periodicity of the scheduled task. Eg. S5 is 5 Sec, H6 is 6 Hours, M8 is 8 Min. Note: This is also used for the time interval for sending I am alive traps." DEFVAL { "0" } ::= {fwuSchedulerEntry 6} fwuFunctionArgs OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Colon separated string of arguments required for the given task type. Can be empty depending on the task type." ::= { fwuSchedulerEntry 7} fwuRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the conceptual row. This is used to manage the creation and deletion of the rows in scheduler table." DEFVAL { notInService } ::= {fwuSchedulerEntry 8} -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Contact Alarm Objects [Rev-7] (.15.2.1.3.6) fwuContactAlarmTraps -- fwuContactAlarmObjects OBJECT IDENTIFIER::= {fwuGeneralObjects 6} -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuContactAlarmInfo OBJECT IDENTIFIER::= { fwuContactAlarmObjects 1 } fwuSystemContactAlarmMgmtTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuSystemContactAlarmMgmtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entities in this table are applicable to all Prism and URH remote units. For Host and DRU, entities are applicable only for 2nd generation system cards and onwards." ::= { fwuContactAlarmInfo 1 } fwuSystemContactAlarmMgmtEntry OBJECT-TYPE SYNTAX FwuSystemContactAlarmMgmtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry (conceptual row) in the fwuSnmpTrapMgrConfigTable." INDEX { fwuUnitIndex, fwuSYstemAlarmCode} ::= { fwuSystemContactAlarmMgmtTable 1 } FwuSystemContactAlarmMgmtEntry ::= SEQUENCE { fwuUnitIndex UnitID2, fwuSYstemAlarmCode Unsigned32, fwuContactAlarm DisplayString, fwuContactAlarmMode INTEGER, fwuContactAlarmName DisplayString, fwuContactAlarmEnable ALARMEnable, fwuContactAlarmSeverity INTEGER } fwuUnitIndex OBJECT-TYPE SYNTAX UnitID2 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the connected unit." ::= {fwuSystemContactAlarmMgmtEntry 1} fwuSYstemAlarmCode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "A code that uniquely identifies an alarm." ::= {fwuSystemContactAlarmMgmtEntry 2} fwuContactAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware Assigned Name." ::= {fwuSystemContactAlarmMgmtEntry 3} fwuContactAlarmMode OBJECT-TYPE SYNTAX INTEGER { normallyClose(1) , normallyOpen(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to set the mode of the alarm as normally closed (1) or normally open (2)." ::= {fwuSystemContactAlarmMgmtEntry 4} fwuContactAlarmName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "User defined name of the host unit. All characters except angular brackets, single and double quotes are allowed. Minimum length of the name is 0 character (It may be empty.). Maximum length of the name is 64 characters." ::= {fwuSystemContactAlarmMgmtEntry 5} fwuContactAlarmEnable OBJECT-TYPE SYNTAX ALARMEnable MAX-ACCESS read-write STATUS current DESCRIPTION "Provision to enable (1) or disable (0) the contact alarm. The alarm is enabled by default." DEFVAL {1} ::= {fwuSystemContactAlarmMgmtEntry 6} fwuContactAlarmSeverity OBJECT-TYPE SYNTAX INTEGER { minor (2) , major(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Severity of the alarm." ::= {fwuSystemContactAlarmMgmtEntry 7} fwuContactAlarmTraps OBJECT IDENTIFIER ::= { fwuContactAlarmObjects 2 } fwuHstContactAlarmOutput1 NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host contact output port state." ::= { fwuContactAlarmTraps 1 } fwuHstContactAlarmOutput2 NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host contact output port state." ::= { fwuContactAlarmTraps 2 } fwuHstContactAlarmInput1 NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host contact input port state." ::= { fwuContactAlarmTraps 3 } fwuHstContactAlarmInput2 NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Host contact input port state." ::= { fwuContactAlarmTraps 4 } fwuRmtContactAlarmInput1 NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Remote contact input port state- Summary of all connected remotes." ::= { fwuContactAlarmTraps 5 } fwuRmtContactAlarmInput2 NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Remote contact input port state- Summary of all connected remotes." ::= { fwuContactAlarmTraps 6 } fwuRmtContactAlarmOutput1 NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Remote contact output port state- Summary of all connected remotes." ::= { fwuContactAlarmTraps 7 } fwuRmtContactAlarmOutput2 NOTIFICATION-TYPE OBJECTS { fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuModuleNumber, fwuModuleType, fwuAlarmedModuleName, fwuHstNumber, fwuHstName, fwuRmtNumber, fwuRmtName, fwuTrapCode, fwuNotificationStatus } STATUS current DESCRIPTION "Remote contact output port state- Summary of all connected remotes." ::= { fwuContactAlarmTraps 8 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Static Alarms Table [Rev-7] (.15.2.1.3.7) fwuStaticAlarmsTable -- fwuSystemStaticAlarms OBJECT IDENTIFIER ::= { fwuGeneralObjects 7 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ fwuSystemStaticAlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF FwuSystemStaticAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a static alarm table containing the statistics of units in the system. The major and minor alarms will be grouped separately for each of the units." ::= { fwuSystemStaticAlarms 1 } fwuSystemStaticAlarmsEntry OBJECT-TYPE SYNTAX FwuSystemStaticAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for units which can be either alarmed or not alarmed or not-discovered." INDEX { fwuSystemUnitID, fwuSystemUnitType } ::= { fwuSystemStaticAlarmsTable 1 } FwuSystemStaticAlarmsEntry ::= SEQUENCE { fwuSystemUnitID UnitID2, fwuSystemUnitType UnitType, fwuUnitMajorAlarms DisplayString, fwuUnitMinorAlarms DisplayString } fwuSystemUnitID OBJECT-TYPE SYNTAX UnitID2 MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the unit from which the alarms has been raised." ::= { fwuSystemStaticAlarmsEntry 1 } fwuSystemUnitType OBJECT-TYPE SYNTAX UnitType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the from which the alarm has been raised." ::= { fwuSystemStaticAlarmsEntry 2 } fwuUnitMajorAlarms OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The major alarm name of the unit." ::= { fwuSystemStaticAlarmsEntry 3 } fwuUnitMinorAlarms OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The minor alarm name of the unit." ::= { fwuSystemStaticAlarmsEntry 4 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Conformance-related definitions (.15.2.1.4) -- flexwaveurhMIBConformance OBJECT IDENTIFIER ::= { flexwaveURHMibModule 4} -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ flexwaveurhMIBCompliances OBJECT IDENTIFIER ::= {flexwaveurhMIBConformance 1} flexwaveurhMIBGroups OBJECT IDENTIFIER ::= {flexwaveurhMIBConformance 2} -- compliance statements flexwaveurhBasicCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for Flexwave entities which implement the ADC-FLEXWAVE-URH-MIB." MODULE -- This Module MANDATORY-GROUPS { fwuSerfGroup, fwuOpticsGroup, fwuDartGroup, fwuLnaGroup, fwuLpaGroup, fwuDuplexerGroup, fwuAlarmConfigGroup, fwuNotificationGroup, fwuLinkingGroup, fwuMateInfoGroup, fwuSprintModeGroup, fwuSNMPSettingGroup } ::= { flexwaveurhMIBCompliances 1 } fwuSerfGroup OBJECT-GROUP OBJECTS { -- Host SERF Objects -- fwuHstNumber, fwuHstName, fwuHstUnitReset, fwuHstBackPlaneRev, fwuHstAlarmStatusSummary, fwuHstTempMeas, fwuSystemAlarmStatusSummary, --fwuHstLinkingMode, fwuHstSystemDateAndTime, fwuAlarmAck, fwuAlarmLevel, fwuUserCommLinkTest, fwuUserLinkTestStatus, fwuUserCommLinkTestDartBandType, fwuUserCommLinkTestDartId, fwuHstpThreadSWVer, fwuClearSysConfig, --fwuPwrUpLinkTest, fwuLinkTestLastRuntime, fwuHstSubagentSWVer, fwuHstWebServerSWVer, fwuHstMajorContactAlarmOutput, fwuHstMinorContactAlarmOutput, fwuRmtMajorContactAlarmOutput, fwuRmtMinorContactAlarmOutput, fwuHstSERFFPGAStatus, fwuHstSysCardRIADCPartNumber, fwuHstSysCardRISerialNumber, fwuHstSysCardRIDateCode, fwuHstSysCardRIHWVer, fwuHstSERFLinuxKernelVer, fwuHstSERFLinuxBootLoaderVer, fwuHstSERFCompactFlashSWVer, fwuHstSERFFPGAVer, fwuHstSERFPPCSNMPAgentSWVer, fwuHstSERFPPCHWMonSWVer, fwuHstSERFPPCAPPMonSWVer, fwuHstSERFPPCMATEMonSWVer, fwuHstSERFPPCENETMonSWVer, fwuHstSERFPPCFPGAMonSWVer, fwuHstSERFRIDateCode, fwuHstSERFRIHWVer, fwuHstSERFRISerialNumber, fwuHstSERFRIADCPartNumber, fwuHstSysCard10MhzRefClock, fwuHstSysCardCPLevel, fwuHstSysCardOutputRefClock, fwuHstSERFRIHWGen, fwuHstSysCardRIHWGen, fwuHstSERFLinuxBootLoaderFirstVer,fwuNTPServerIP, fwuSyncNTPServer, -- Remote SERF Objects -- fwuRmtNumber, fwuRmtCatalogState, fwuRmtName, fwuRmtAlarmStatusSummary, fwuRmtTempMeasurement, fwuRmtGeneralTableRowStatus, fwuRmtType, fwuDruIfCombinerReboot, fwuUsrCommLinkTestIFBr, fwuUsrCommLinkTestIFBrDType, fwuUsrCommLinkTestDartId, fwuDruBackPlaneRev, fwuRmtSERFFPGAStatus, fwuRmtRSIRIADCPartNumber, fwuRmtRSIRISerialNumber, fwuRmtRSIRIDateCode, fwuRmtRSIRIHWVer, fwuRmtCapacity, fwuRmtSERFLinuxKernelVer, fwuRmtSERFRIHWGen, fwuRmtWebServerSWVer, fwuRmtpThreadSWVer, fwuRmtSERFLinuxBootLoaderVer, fwuRmtSERFCompactFlashSWVer, fwuRmtSERFFPGAVer, fwuRmtSERFPPCHWMonSWVer, fwuRmtSERFPPCAPPMonSWVer, --fwuRmtSERFPPCGPSMonSWVer, --fwuRmtSERFPPCSNMPAgentSWVer, fwuRmtSERFPPCMATEMonSWVer, fwuRmtSERFPPCENETMonSWVer, fwuRmtSERFPPCFPGAMonSWVer, fwuRmtSERFRIDateCode, fwuRmtSERFRIHWVer, fwuRmtSERFRISerialNumber, fwuRmtSERFRIADCPartNumber, fwuPrismUnitReset } STATUS current DESCRIPTION "A collection of Host and Remote SERF objects." ::= { flexwaveurhMIBGroups 1 } fwuOpticsGroup OBJECT-GROUP OBJECTS { -- Host Optics & Ethernet -- fwuHstSERFOptSFPNumber, fwuHstSERFOptSFPName, fwuHstSERFOptSFPType, fwuHstSERFOptSFPTxColor, fwuHstSERFOptRevLaunchPowerMeas, fwuHstSERFOptFwdLaunchPowerMeas, fwuHstSERFOptMateName, fwuHstSERFIPEnable, fwuHstSERFOptMateId, fwuHstSERFOptMateSfpId, fwuHstSERFEthPortNumber, fwuHstSERFEthPortType, fwuHstSERFEthPortRxBytes, fwuHstSERFEthPortRxPkts, fwuHstSERFEthPortRxFcsErrors, fwuHstSERFEthPortRxBroadcastPkts, fwuHstSERFEthPortRxMulticastPkts, fwuHstSERFEthPortRxFragmtdFrames, fwuHstSERFEthPortRxJabbersFrames, fwuHstSERFEthPortTxByteCounter, fwuHstSERFEthPortTxPkts, fwuHstSERFEthPortTxBroadcastPkts, fwuHstSERFEthPortTxMulticastPkts, fwuHstSERFEthPortSFPId, -- Remote Optics & Ethernet -- fwuRmtSERFOptSFPNumber, fwuRmtSERFOptSFPName, fwuRmtSERFOptSFPType, fwuRmtSERFOptSFPColor, fwuRmtSERFOptRevLaunchPowerMeas, fwuRmtSERFOptFwdLaunchPowerMeas, fwuRmtSERFOptMateName, fwuRmtSERFIPEnable, fwuRmtSERFOptMateId, fwuRmtSERFOptMateSfpId, fwuRmtSERFOptMateSfpDir, fwuRmtSERFEthPortNumber, fwuRmtSERFEthPortType, fwuRmtSERFEthPortRxBytes, fwuRmtSERFEthPortRxPkts, fwuRmtSERFEthPortRxFcsErrors, fwuRmtSERFEthPortRxBroadcastPkts, fwuRmtSERFEthPortRxMulticastPkts, fwuRmtSERFEthPortRxFragmtdFrames, fwuRmtSERFEthPortRxJabbersFrames, fwuRmtSERFEthPortTxByteCounter, fwuRmtSERFEthPortTxPkts, fwuRmtSERFEthPortTxBroadcastPkts, fwuRmtSERFEthPortTxMulticastPkts, fwuRmtSERFEthPortSFPId, fwuRmtSERFOptHostIP } STATUS current DESCRIPTION "A collection of Host and Remote Optical and Ethernet port objects." ::= { flexwaveurhMIBGroups 2 } fwuDartGroup OBJECT-GROUP OBJECTS { -- Host Dart -- fwuHstDARTNumber, fwuHstDARTName, fwuHstDARTBandType, fwuHstDARTPassBand, fwuHstDARTOperatingMode, fwuHstDARTDiversityStatus, fwuHstDARTForwardGain, fwuHstDARTReverseGain, fwuHstDARTFPGAStatus, fwuHstDARTFPGAProgramVer, fwuHstDARTRIADCPartNumber, fwuHstDARTRISerialNumber, fwuHstDARTRIDateCode, fwuHstDARTRIHWVer, fwuHstDARTRowStatus, fwuHstDARTPeakInputPwrLvl1, fwuHstDARTPeakInputPwrLvl2, fwuHstDARTPeakAvgInputPwrLvl1, fwuHstDARTPeakAvgInputPwrLvl2, fwuHstDARTMinAvgInputPwrLvl1, fwuHstDARTMinAvgInputPwrLvl2, fwuHstDARTInputPowerMode, fwuHstDARTPwrLevelMaxHoldReset, fwuHstDARTLastMaxHoldResetTime, fwuHstDARTInputSrc, -- Remote Dart -- fwuRmtDARTNumber, fwuRmtDARTName, fwuRmtDARTBandType, fwuRmtDARTPassBand, fwuRmtDARTOperatingMode, fwuRmtDARTDiversityStatus, fwuRmtDARTForwardGain, fwuRmtDARTReverseGain, fwuRmtDARTForwardDelay, fwuRmtDARTReverseDelay, fwuRmtDARTTempMeas, fwuRmtDARTFPGAStatus, fwuRmtDARTFPGAProgramVer, fwuRmtDARTRIADCPartNumber, fwuRmtDARTRISerialNumber, fwuRmtDARTRIDateCode, fwuRmtDARTRIHWVer, fwuRmtDARTGeneralTableRowStatus, fwuRmtDARTActualForwardDelay, fwuRmtDARTForwardLowerboundDelay, fwuRmtDARTForwardUpperboundDelay, fwuRmtDARTActualReverseDelay, fwuRmtDARTReverseLowerboundDelay, fwuRmtDARTReverseUpperboundDelay, fwuRmtDARTPeakInputPwrLvl1, fwuRmtDARTPeakInputPwrLvl2, fwuRmtDARTPeakAvgInputPwrLvl1, fwuRmtDARTPeakAvgInputPwrLvl2, fwuRmtDARTMinAvgInputPwrLvl1, fwuRmtDARTMinAvgInputPwrLvl2, fwuRmtDARTInputPowerMode, fwuRmtDARTPwrLevelMaxHoldReset, fwuRmtDARTLastMaxHoldResetTime, fwuRmtDARTReverseGainMode, fwuRmtDARTTxRIADCPartNumber, fwuRmtDARTTxRISerialNumber, fwuRmtDARTTxRIDateCode, fwuRmtDARTTxRIHWVer, fwuRmtDARTLinkedStatus, fwuRmtDARTAvailable, fwuRmtDARTUsedSFP } STATUS current DESCRIPTION "A collection of Host and Remote DART objects." ::= { flexwaveurhMIBGroups 3 } fwuLnaGroup OBJECT-GROUP OBJECTS { fwuRmtLNANumber, fwuRmtLNAType, fwuRmtLNARIADCPartNumber, fwuRmtLNARISerialNumber, fwuRmtLNARIDateCode, fwuRmtLNARIHWVer, fwuRmtDuplexerType } STATUS current DESCRIPTION "A collection of Host and Remote LNA objects." ::= { flexwaveurhMIBGroups 4 } fwuLpaGroup OBJECT-GROUP OBJECTS { fwuRmtLPANumber, fwuRmtLPAReset, fwuRmtLPAOpState, fwuRmtLPAPartNum, fwuRmtLPASerialNum, fwuRmtLPAHWVer, fwuRmtLPASWVer, fwuRmtLPADescr, fwuRmtLPAControl, fwuRmtLPAMaxOpPwr, fwuRmtLPABandType } STATUS current DESCRIPTION "A collection of Host and Remote LPA objects." ::= { flexwaveurhMIBGroups 5 } fwuDuplexerGroup OBJECT-GROUP OBJECTS { fwuRmtPowerDetectorNumber, fwuRmtSystemVswrMeas, fwuRmtRFPowerOutputMeas, fwuRmtPwrDetectorBoardRIADCPartNum, fwuRmtPwrDetectorBoardRISerialNum, fwuRmtPwrDetectorBoardRIDateCode, fwuRmtPwrDetectorBoardRIHWVer, fwuRmtRDINumber, fwuRmtRDIRIADCPartNumber, fwuRmtRDIRISerialNumber, fwuRmtRDIRIDateCode, fwuRmtRDIRIHWVer, fwuRmtRDIRIHWType, fwuRmtPwrDetectorNoRfPowerThershold, fwuRmtSystemVSWRThreshold} STATUS current DESCRIPTION "A collection of Host and Remote Duplexer objects." ::= { flexwaveurhMIBGroups 6 } fwuAlarmConfigGroup OBJECT-GROUP OBJECTS { fwuSystemAlarmTrapNodeAddress, fwuSystemlabel, fwuSystemAlarmRmtName, fwuSystemAlarmRmtType, fwuSystemAlarmModuleType, fwuSystemAlarmModuleNumber, fwuSystemAlarmModuleName, fwuSystemAlarmSeverity, fwuSystemAlarmRFBand, fwuSystemAlarmTimeStamp, fwuSystemAlarmCode, fwuSystemAlarmHstNbr, fwuSystemAlarmAnalogAddress, fwuRmtMajorContactAlarmOutput, fwuRmtMinorContactAlarmOutput, fwuTrapSequenceNumber, fwuTrapTimeStamp, fwuNotificationStatus, fwuModuleType, fwuModuleNumber, fwuTrapCode, fwuTrapNodeAddress, fwuAlarmedModuleName, fwuUnitIndex, fwuSYstemAlarmCode, fwuContactAlarm, fwuContactAlarmMode, fwuContactAlarmName, fwuContactAlarmEnable, fwuContactAlarmSeverity, fwuSystemAlarmManageable, fwuSystemAlarmThreshold, fwuSystemAlarmModType, fwuSystemAlarmcode, fwuSystemTrapNodeAddress, fwuSystemAlarmModuleNo, fwuSystemModuleAlarmcode, fwuSystemAlarmEnabled } STATUS current DESCRIPTION "A collection of Host and Remote Alarm configuration objects." ::= { flexwaveurhMIBGroups 7 } fwuNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { fwuHstModuleMissingFault, fwuHstOverTempFault, fwuHstUnderTempFault, fwuHstSysCardFanFault, fwuHstSysCardClockMismatchFault, fwuHstSERFSynthAlarmFault, fwuHstSERFFault, fwuHstSERFRmtLostFault, fwuHstSERFOptRxBERFault, fwuHstSERFOptRxNoLightFault, fwuHstSERFOptLaserFault, fwuHstSERFOptOverDriveFault, fwuHstSERFOptUnderDriveFault, fwuHstSERFOptIpEnableFault, fwuMastClockPriorityLvlConflict, fwuHstI2CBus1Fault, fwuHstI2CBus2Fault, fwuHstDARTFault, fwuHstDARTDCSupplyFault, fwuHstDARTHardwareMismatchFault, fwuHstDARTDwnCon1SynLockFault, fwuHstDARTDwnCon2SynLockFault, fwuHstDARTUpConSynLockFault, fwuHstDARTOverDriveFault, fwuHstDARTUnderDriveFault, fwuHstDARTALCLimitingFault, fwuHstDARTLinkingConflictFault, fwuHstIamAliveFault, fwuRmtModuleMissingFault, fwuRmtOverTempFault, fwuRmtUnderTempFault, fwuRmtOpenDoorFault, fwuRmtFanOverSpeedFault, fwuRmtFanUnderSpeedFault, fwuSWVersionMismatchFault, fwuDruSysCardFanFault, fwuDruOverTempFault, fwuDruUnderTempFault, fwuRmtAcPowerSupplyFault, fwuRmtMajorExtAlarmInputFault, fwuRmtMinorExtAlarmInputFault, fwuRmtSERFHstLostFault, fwuRmtSERFOptRxBERFault, fwuRmtSERFOptRxNoLightFault, fwuRmtSERFOptLaserFault, fwuRmtSERFOptOverDriveFault, fwuRmtSERFOptUnderDriveFault, fwuRmtSERFSynthAlarmFault, fwuRmtSERFFault, fwuRmtI2CBus1Fault, fwuRmtI2CBus2Fault, fwuRmtDARTDwnCon1SynLockFault, fwuRmtDARTDwnCon2SynLockFault, fwuRmtDARTUpConSynLockFault, fwuRmtDARTDCSupplyFault, fwuRmtDARTFault, fwuRmtDARTHardwareMismatchFault, fwuRmtRangingFault, fwuRmtDARTOverTempFault, fwuRmtDARTLowTempFault, fwuRmtDARTUplinkInactivityFault, fwuRmtDARTCommsFault, fwuRmtLPADisableFault, fwuRmtLPAOverPowerFault, fwuRmtLPAHighTempFault, fwuRmtLPAVswrFault, fwuRmtLPADcFault, fwuRmtLPALoopFault, fwuRmtLPALowPowerFault, fwuRmtLPADetectFault, fwuRmtPaOverCurrentFault, fwuRmtSystemVswrFault, fwuRmtRFPowerFault, fwuRmtLNAPowerFault, fwuRmtDuplexerFreqMismatchFault, fwuRmtACPowerSupplyMon4Fault, fwuRmtACPowerSupplyMon1Fault, fwuRmtACPowerSupplyMon2Fault, fwuRmtACPowerSupplyMon3Fault, fwuHstBTSUnderPowerFault, fwuHstFLMDownconvertFailureFault, fwuHstRLMUpconvertFailureFault, fwuHstRLMUpConIndetFault, fwuRmtDownLinkCalToneFailureFault, fwuRmtUplinkFailureDetectLowFault, fwuRmtUpConvertFailureFault, fwuRmtUnderPowerFault, fwuRmtDownConvertFailureFault, fwuRmtUpconIndetFault, fwuRmtFiberConnMismatchFault, fwuRmtExcessConnFault, fwuRmtInvalidDevConnFault, fwuDruSysCardClockMismatchFault, fwuDruNoCommsFault, fwuHstContactAlarmOutput1, fwuHstContactAlarmOutput2, fwuHstContactAlarmInput1, fwuHstContactAlarmInput2, fwuRmtContactAlarmInput1, fwuRmtContactAlarmInput2, fwuRmtContactAlarmOutput1, fwuRmtContactAlarmOutput2 } STATUS current DESCRIPTION "A collection of Host and Remote Notification objects." ::= { flexwaveurhMIBGroups 8 } fwuLinkingGroup OBJECT-GROUP OBJECTS { fwuMappingStatus, fwuUnitID, fwuUnitDARTID, fwuUnitSFPID, fwuUnitDartPassBand, fwuMateID, fwuMateDARTID, fwuMateSFPID, fwuMateDartPassband, fwuSFPStartTimeSlot, fwuSFPEndTimeSlot, fwuDARTMappingIndex } STATUS current DESCRIPTION "A collection of RF linking configuration objects." ::= { flexwaveurhMIBGroups 9 } fwuMateInfoGroup OBJECT-GROUP OBJECTS { fwuHMmonRmtID, fwuHMmonRmtIPAddress --fwuRMmonIndex, --fwuRMmonHstIPAddress, --fwuRMmonHstID, --fwuRMmonRmtID } STATUS current DESCRIPTION "A collection of mate information objects." ::= { flexwaveurhMIBGroups 10 } fwuSprintModeGroup OBJECT-GROUP OBJECTS { --fwuGeoHeartbeatTimer, fwuGeoIndex, fwuGeoLatitude, fwuGeoLongitude, fwuGeoRmtName, fwuGeoStatus } STATUS current DESCRIPTION "A collection of objects supported in Sprint mode Objects." ::= { flexwaveurhMIBGroups 11 } fwuSNMPSettingGroup OBJECT-GROUP OBJECTS { fwuV1TrapAgentAddrOverrideMode, fwuV1TrapAgentAddrOverrideIPAddr, fwuSnmpTrapResendInterval, fwuSnmpTrapResendMaximum, fwuEnableNotifHysteresis, fwuEventNotifHysteresis, fwuEnableNotifInterval, fwuEventNotifInterval, --fwuImAliveTrapInterval, --fwuEthernetModemWakeUp, fwuTrapMgrIpAddress, fwuTrapMgrListeningPort, fwuTrapMgrCommunity, fwuTrapVersion, fwuTrapMgrRowStatus, fwuTaskType, fwuScheduleStatus, fwuTaskStartTime, fwuOccurrences, fwuRecurrence, fwuFunctionArgs, fwuRowStatus } STATUS current DESCRIPTION "A collection of objects supported in System Link test." ::= { flexwaveurhMIBGroups 12 } fwuSystemStaticAlarmsGroup OBJECT-GROUP OBJECTS { fwuSystemUnitID, fwuSystemUnitType, fwuUnitMajorAlarms, fwuUnitMinorAlarms } STATUS current DESCRIPTION "A collection of objects supported in Static Alarms Table." ::= { flexwaveurhMIBGroups 13 } END