-- *************************************************************************** -- (c) Copyright, Armillaire Tecnologies, Inc. -- ALL RIGHTS RESERVED -- -- Armillaire Technologies, Inc. -- 6707 Democracy Blvd, Suite 200 -- Bethesda, MD 20817, USA -- -- -- Description Armillaire MSSC MIB (SNMPv1) -- -- **************************************************************************** ARMILLAIRE2000-MIB DEFINITIONS ::= BEGIN IMPORTS TRAP-TYPE FROM RFC-1215 enterprises, Counter, Gauge, IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB; armillaire OBJECT IDENTIFIER ::= { enterprises 4618 } RowStatus ::= INTEGER { createandwait( 5), destroy( 6), active( 1), notinservice( 2), notready( 3), modified( 17), up( 22), down( 23), outofservice( 18)} LrnRowStatus ::= INTEGER { createandwait( 5), destroy( 6), active( 1), notinservice( 2), notready( 3), outofservice( 18)} CktRowStatus ::= INTEGER { createandwait( 5), destroy( 6), active( 1), notinservice( 2), notready( 3), modified( 17), up( 22), down( 23), modifytimer( 99), outofservice( 18), block( 20)} TmrRowStatus ::= INTEGER { modifytimer( 99), active( 1), notinservice( 2), notready( 3), modified( 17), up( 22), down( 23), outofservice( 18)} UserLoginStatus ::= INTEGER { login( 1), logininvalid( 2), adduser( 3), deleteuser( 4)} UserLoginPriority ::= INTEGER { admin( 1), cts( 2), user( 8738)} ProcessStatus ::= INTEGER { down( 1), active( 34), standby( 51), outofservice( 170), switchingover( 3), unknown( 172)} IsdnPriority ::= INTEGER { primary( 0), secondary( 1), bearing( 2)} IsdnType ::= INTEGER { nfas( 1), fas( 0)} OpStatus ::= INTEGER { active( 1), down( 23)} LinkOpStatus ::= INTEGER { active( 1), down( 23), inhibit( 19)} LinkSetOpStatus ::= INTEGER { active( 1), deactive( 23)} CktOpStatus ::= INTEGER { active( 1), down( 23), block( 20)} IsdnTrnkOpStatus ::= INTEGER { active( 1), down( 23), disable( 21)} ModifyTmrStatus ::= INTEGER { modifytimer( 99), noaction( 0)} IfType ::= INTEGER { interface-t1( 0), interface-t3( 1), interface-ut3( 2), interface-oc3( 3), interface-ut3cp( 4), interface-oc3cp( 5), interface-e1( 8), interface-hde1( 9), interface-une3( 10), interface-stm( 11), interface-oc3aps( 12), interface-stm1aps( 13)} AtmIfType ::= INTEGER { interface-t1( 0), interface-e1( 8)} ConnectionType ::= INTEGER { t3( 1), ut3( 2), e3( 10)} EnableStatus ::= INTEGER { yes( 1), no( 2)} Ss7RouteType ::= INTEGER { load( 0)} AddrIdentifier ::= INTEGER { unknown( 2), nationalnumber( 3)} AddrType ::= INTEGER { callpartynum( 1), transitnetwork( 2)} NumPlan ::= INTEGER { nonumber( 0), isdnnumplan( 1)} Direction ::= INTEGER { in( 0), out( 1), both( 2)} EnableOperation ::= INTEGER { enable( 16), disable( 17)} IsdnChnlMgtOperation ::= INTEGER { enable( 11), disable( 12)} IsdnTrnkMgtOperation ::= INTEGER { enable( 9), disable( 10)} BlockOperation ::= INTEGER { block( 5), unblock( 6), noaction( 0)} Level ::= INTEGER { level1( 1), level2( 2)} ModemResetStatus ::= INTEGER { yes( 1), no( 0)} ModemEnableStatus ::= INTEGER { enable( 1), disable( 0)} MeasEnableStatus ::= INTEGER { enable( 1), disable( 0)} EthernetConnStatus ::= INTEGER { up( 1), down( 2)} Standard ::= INTEGER { ansi( 65), itu( 73), telmex( 84)} TrunkType ::= INTEGER { ss7( 34), isdn( 17)} RouteType ::= INTEGER { ss7RouteType( 1), isdnRouteType( 2)} AuditType ::= INTEGER { ansi( 65), itu( 73)} AuditOperation ::= INTEGER { audit( 1), noaction( 0)} Controlstatus ::= INTEGER { blockckt( 5), unblock( 6), enablechnl( 11), disablechnl( 12), noaction( 0)} LinkControlStatus ::= INTEGER { inhibitlink( 1), uninhibitlink( 2), noaction( 0)} LinkSetControlStatus ::= INTEGER { activatelnkset( 3), deactivatelnkset( 4), noaction( 0)} CircuitControlStatus ::= INTEGER { blockcic( 7), unblockcic( 8), queryckt( 13), validateckt( 14), resetckt( 15), noaction( 0)} IsdnControlstatus ::= INTEGER { enabletrnk( 9), disabletrnk( 10), noaction( 0)} MtpRteState ::= INTEGER { rteavail( 1), rteunaval( 0)} Bool ::= INTEGER { yes( 1), no( 0)} LoadBalance ::= INTEGER { disable( 0), enable( 1)} TrnkGrpType ::= INTEGER { ss7( 32), isdn( 33)} ActiveAlarmAckStatus ::= INTEGER { clear( 0), noaction( 1)} EventType ::= INTEGER { alarm( 1), emergency( 2), audit( 3), diagnostics( 4), security( 5), maintenance( 6)} AlarmEvent ::= INTEGER { general( 1), device( 2), protocol( 3), mfd( 4), cdr( 5), measurement( 6), log( 7), ig( 8), faultTolerance( 9), nomainevent( 0)} AlarmSubEvent ::= INTEGER { administration( 1), nosubevent( 0), operation( 2), mssc( 3), xconnect( 4), hub( 5), ss7lnk( 6), ss7Br( 7), isdn( 8), atm( 9)} AlarmSeverity ::= INTEGER { critical( 1), major( 2), minor( 3), informational( 4)} RoffType ::= INTEGER { le( 1), tandem( 2), intlgateway( 3)} NameString ::= DisplayString(SIZE(1..24)) AddrString ::= DisplayString(SIZE(1..24)) CdrFlag ::= INTEGER { noCdr( 0), ic( 1), og( 2), bi( 3)} DSPCardType ::= INTEGER { dsp2B( 1), dsp2C( 2)} VoicePcm ::= INTEGER { alaw( 101), ulaw( 102)} TGFeature ::= INTEGER { enable( 1), disable( 0)} FTswitchOver ::= INTEGER { ftsig( 0), fticc( 1), ftisdn( 2), ftsphr( 3), ftlm( 4)} LogFileAttr ::= INTEGER { alarmlog( 3), auditlog( 2), measlog( 7), diaglog( 1), scrtylog( 4), eventlog( 5), billlog( 8), emplog( 6)} LogFileEnDis ::= INTEGER { alarmlog( 3), auditlog( 2), measlog( 7), diaglog( 1), scrtylog( 4), eventlog( 5), billlog( 8), emplog( 6), logall( 11), noaction( 0)} SwitchType ::= INTEGER { national( 0), international( 1)} LinkType ::= INTEGER { speed-56K( 53), speed-64K( 54)} LogType ::= INTEGER { on( 49), off( 48)} EnableTrace ::= INTEGER { enable( 1), disable( 0)} TrunkState ::= INTEGER { idle( 0), unEquipped( 255), cP-Busy( 1), maintainance-Busy( 2)} MeasPurgeFlag ::= INTEGER { autoOff( 0), autoOn( 1)} E1MultiFrame ::= INTEGER { cas( 1), ccs( 2)} E1CRC4 ::= INTEGER { enabled( 1), disabled( 2)} TransClkSrc ::= INTEGER { loopTiming( 1), localTiming( 2)} DS1LineType ::= INTEGER { esF( 1), d4( 2)} DS1LineCoding ::= INTEGER { b8zs( 1), ami( 2)} DS1LBO ::= INTEGER { upTo133Feet( 1), upTo266Feet( 2), upTo399Feet( 3), upTo533Feet( 4), upTo655Feet( 5), negative7-5Db( 6), negative15Db( 7), negative22-5Db( 8)} DS3LineType ::= INTEGER { cbitParity( 1), clearChannel( 2)} DS3LBO ::= INTEGER { short( 1), long( 2)} DS3ATMCellMap ::= INTEGER { plcp( 1), directMapping( 2)} TimerType ::= INTEGER { ansi( 1), itu( 2)} products OBJECT IDENTIFIER ::= { armillaire 1 } services OBJECT IDENTIFIER ::= { armillaire 2 } armillaire2000 OBJECT IDENTIFIER ::= { products 2 } -- ************************************************* -- MSSC group -- ************************************************* switchInfo OBJECT IDENTIFIER ::= { armillaire2000 1 } switchConfig OBJECT IDENTIFIER ::= { armillaire2000 2 } switchMeas OBJECT IDENTIFIER ::= { armillaire2000 3 } switchCdr OBJECT IDENTIFIER ::= { armillaire2000 4 } switchFeature OBJECT IDENTIFIER ::= { armillaire2000 5 } switchMaintenance OBJECT IDENTIFIER ::= { armillaire2000 6 } switchTrap OBJECT IDENTIFIER ::= { armillaire2000 7 } -- ************************************************* -- Switch Information Group -- ************************************************* switchGenInfoGrp OBJECT IDENTIFIER ::= { switchInfo 1 } switchPcInfo OBJECT IDENTIFIER ::= { switchInfo 2 } switchUsrInfo OBJECT IDENTIFIER ::= { switchInfo 3 } switchVersionGrp OBJECT IDENTIFIER ::= { switchInfo 4 } -- ************************************************* -- Switch Configuration Group -- ************************************************* ss7 OBJECT IDENTIFIER ::= { switchConfig 1 } isdn OBJECT IDENTIFIER ::= { switchConfig 2 } trnkGrp OBJECT IDENTIFIER ::= { switchConfig 3 } rt OBJECT IDENTIFIER ::= { switchConfig 4 } xconnect OBJECT IDENTIFIER ::= { switchConfig 5 } enableGroup OBJECT IDENTIFIER ::= { switchConfig 6 } -- ************************************************* -- Switch Measurement Group -- ************************************************* measFile OBJECT IDENTIFIER ::= { switchMeas 1 } measSwitch OBJECT IDENTIFIER ::= { switchMeas 2 } measTrnkGrp OBJECT IDENTIFIER ::= { switchMeas 3 } measLnk OBJECT IDENTIFIER ::= { switchMeas 4 } -- ************************************************* -- Switch Features Group -- ************************************************* modemFaultDetection OBJECT IDENTIFIER ::= { switchFeature 1 } lnp OBJECT IDENTIFIER ::= { switchFeature 2 } switchDSP OBJECT IDENTIFIER ::= { switchFeature 3 } switchTGFeature OBJECT IDENTIFIER ::= { switchFeature 4 } -- ************************************************* -- Switch Maintenance Group -- ************************************************* ft OBJECT IDENTIFIER ::= { switchMaintenance 1 } log OBJECT IDENTIFIER ::= { switchMaintenance 2 } trace OBJECT IDENTIFIER ::= { switchMaintenance 3 } processStatus OBJECT IDENTIFIER ::= { switchMaintenance 4 } ethernetConnStatusInfo OBJECT IDENTIFIER ::= { switchMaintenance 5 } audit OBJECT IDENTIFIER ::= { switchMaintenance 6 } -- ************************************************* -- Switch Trap Group -- ************************************************* trapObjects OBJECT IDENTIFIER ::= { switchTrap 1 } alarmGrp OBJECT IDENTIFIER ::= { switchTrap 2 } -- ************************************************* -- Switch Maintenance Group [ FT ] -- ************************************************* ftSwitchOverInfo OBJECT IDENTIFIER ::= { ft 1 } -- ************************************************* -- Switch Maintenance Group [LOG ] -- ************************************************* logFileInfo OBJECT IDENTIFIER ::= { log 1 } logFileGenEnable OBJECT IDENTIFIER ::= { log 2 } logFileAttribute OBJECT IDENTIFIER ::= { log 3 } -- ************************************************* -- Switch Maintenance Group [Audit ] -- ************************************************* auditInfo OBJECT IDENTIFIER ::= { audit 1 } -- ************************************************* -- Switch Maintenance Group [Trace ] -- ************************************************* ss7LnkTrace OBJECT IDENTIFIER ::= { trace 1 } ss7RouteTrace OBJECT IDENTIFIER ::= { trace 2 } isdnTrnkTrace OBJECT IDENTIFIER ::= { trace 3 } -- ************************************************* -- Switch Maintenance Group [ProcessStatus ] -- ************************************************* processStatusInfo OBJECT IDENTIFIER ::= { processStatus 1 } -- ************************************************* -- SS7 Configuration Group -- ************************************************* ss7Sig OBJECT IDENTIFIER ::= { ss7 1 } ss7Br OBJECT IDENTIFIER ::= { ss7 2 } mtp2 OBJECT IDENTIFIER ::= { ss7 3 } mtp3 OBJECT IDENTIFIER ::= { ss7 4 } isup OBJECT IDENTIFIER ::= { ss7 5 } ss7Route OBJECT IDENTIFIER ::= { ss7 6 } -- ************************************************* -- mtp3 gen Timer -- ************************************************* mtp3GenTmrCfgGroup OBJECT IDENTIFIER ::= { mtp3 1 } -- ************************************************* -- ISUP group -- ************************************************* switchName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "The switch Name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 24 characters " ::= { switchGenInfoGrp 1 } switchDescr OBJECT-TYPE SYNTAX DisplayString(SIZE(1..255)) ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Switch. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 255 characters. " ::= { switchGenInfoGrp 2 } switchLocation OBJECT-TYPE SYNTAX DisplayString(SIZE(1..255)) ACCESS read-write STATUS mandatory DESCRIPTION "Location of the Switch. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 255 characters. " ::= { switchGenInfoGrp 3 } switchContact OBJECT-TYPE SYNTAX DisplayString(SIZE(1..24)) ACCESS read-write STATUS mandatory DESCRIPTION "Contact information about the Switch. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 24 characters. " ::= { switchGenInfoGrp 4 } switchIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Switch IP address. In xxx.xxx.xxx.xxx format. " ::= { switchGenInfoGrp 5 } switchUpTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The Time (in Seconds) since last restart of the Switch " ::= { switchGenInfoGrp 6 } switchVersion OBJECT-TYPE SYNTAX DisplayString(SIZE(1..24)) ACCESS read-only STATUS mandatory DESCRIPTION "The version of current Switch " ::= { switchGenInfoGrp 7 } switchVerDescr OBJECT-TYPE SYNTAX DisplayString(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The description of switch version " ::= { switchGenInfoGrp 8 } systemDescr OBJECT-TYPE SYNTAX DisplayString(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The description of the System " ::= { switchGenInfoGrp 9 } switchType OBJECT-TYPE SYNTAX SwitchType ACCESS read-only STATUS mandatory DESCRIPTION "The Switch Type : (National/International) " ::= { switchGenInfoGrp 10 } switchNameStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this Switch Name. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the GET Operation, the possible options are 1) active 2) notinservice 3) no" ::= { switchGenInfoGrp 11 } -- ************************************************* -- switch pointcode information -- ************************************************* switchPcInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SwitchPcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Point code Information Table.The index of this table is switchPc (Integer). " ::= { switchPcInfo 1 } switchPcEntry OBJECT-TYPE SYNTAX SwitchPcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { switchPc } ::= { switchPcInfoTable 1 } SwitchPcEntry ::= SEQUENCE { switchPc INTEGER, switchPcMode Standard, switchPcStatus RowStatus } switchPc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Point Code for the switch (the Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { switchPcEntry 1 } switchPcMode OBJECT-TYPE SYNTAX Standard ACCESS read-write STATUS mandatory DESCRIPTION "Point Code type (ANSI/ITU) " ::= { switchPcEntry 2 } switchPcStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this Switch Point Code. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservic" ::= { switchPcEntry 3 } -- ************************************************* -- switch User information Table -- ************************************************* switchUserCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SwitchUserCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This Table is to maintain the User information and providing Validation Checks for Authorised users for Configuration.The index of this table is switchUserId (Integer). CURRENTLY NOT APPLICABLE " ::= { switchUsrInfo 1 } switchUserCfgEntry OBJECT-TYPE SYNTAX SwitchUserCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. CURRENTLY NOT APPLICABLE " INDEX { switchUserId } ::= { switchUserCfgTable 1 } SwitchUserCfgEntry ::= SEQUENCE { switchUserId INTEGER, switchUserName NameString, switchUserPassword NameString, switchUserPriority UserLoginPriority, switchUserStatus UserLoginStatus } switchUserId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Id of the Switch User. The user can only 'SET' User Id. If user tries to 'GET' the user Id, incorrect value would be displayed. This Feature is CURRENTLY NOT APPLICABLE " ::= { switchUserCfgEntry 1 } switchUserName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "The NAME of the Switch User. The user can only 'SET' User NAME. If user tries to 'GET' the user Id, incorrect value would be displayed. This Feature is CURRENTLY NOT APPLICABLE " ::= { switchUserCfgEntry 2 } switchUserPassword OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "The PASSWORD of the Switch User. This is in an encrypted format. This is not visible to user.The user can only set password . This Feature is CURRENTLY NOT APPLICABLE " ::= { switchUserCfgEntry 3 } switchUserPriority OBJECT-TYPE SYNTAX UserLoginPriority ACCESS read-write STATUS mandatory DESCRIPTION "The PRIORITY of the Switch User. User Priority by default is ADMINISTRATOR. This Feature is CURRENTLY NOT APPLICABLE " ::= { switchUserCfgEntry 4 } switchUserStatus OBJECT-TYPE SYNTAX UserLoginStatus ACCESS read-write STATUS mandatory DESCRIPTION "Checks whether user is a valid user. Only the user with administrative privilege can login. This Feature is CURRENTLY NOT APPLICABLE " ::= { switchUserCfgEntry 5 } -- ************************************************* -- switch Version group -- ************************************************* switchVerLM OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Switch's Process LM Version number " ::= { switchVersionGrp 1 } switchVerMTP2 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Switch's Process MPT2 Version number " ::= { switchVersionGrp 2 } switchVerICC OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Switch's Process ICC Version number " ::= { switchVersionGrp 3 } switchVerSIG OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Switch's Process SIG Version number " ::= { switchVersionGrp 4 } switchVerISDN OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Switch's Process ISDN Version number " ::= { switchVersionGrp 5 } switchVerSPHR OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Switch's Process SPHR Version number " ::= { switchVersionGrp 6 } -- ************************************************* -- ss7 link configuration table -- ************************************************* ss7LinkCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7LinkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 Link Table. Information about the SS7 Link(s) in MSSC are provided in this table. The index of this table is ss7LinkName (String) " ::= { ss7Sig 1 } ss7LinkCfgEntry OBJECT-TYPE SYNTAX Ss7LinkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7LinkName } ::= { ss7LinkCfgTable 1 } Ss7LinkCfgEntry ::= SEQUENCE { ss7LinkName NameString, ss7LinkId INTEGER, ss7LinkTrunkId INTEGER, ss7LinkChannel INTEGER, ss7LinkSlc INTEGER, ss7LinkSpeed LinkType, ss7LinkMode Standard, ss7LinkRowStatus RowStatus, ss7LinkOpStatus LinkOpStatus } ss7LinkName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "Link name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters. " ::= { ss7LinkCfgEntry 1 } ss7LinkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "User assigned Link id. Can be any integer 1-65535. " ::= { ss7LinkCfgEntry 2 } ss7LinkTrunkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "User assigned Trunk id. " ::= { ss7LinkCfgEntry 3 } ss7LinkChannel OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "User assigned channel. " ::= { ss7LinkCfgEntry 4 } ss7LinkSlc OBJECT-TYPE SYNTAX INTEGER(0..15) ACCESS read-write STATUS mandatory DESCRIPTION "Link Selection Code. Can be any integer 0-15. " ::= { ss7LinkCfgEntry 5 } ss7LinkSpeed OBJECT-TYPE SYNTAX LinkType ACCESS read-only STATUS mandatory DESCRIPTION "SS7 Link Speed: Possible Values are: 56k or 64k. Default Value is 64K " ::= { ss7LinkCfgEntry 6 } ss7LinkMode OBJECT-TYPE SYNTAX Standard ACCESS read-write STATUS mandatory DESCRIPTION "Link Mode(ANSI/ITU) " ::= { ss7LinkCfgEntry 7 } ss7LinkRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this Link. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notread" ::= { ss7LinkCfgEntry 8 } ss7LinkOpStatus OBJECT-TYPE SYNTAX LinkOpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this SS7 Link. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) inhibit " ::= { ss7LinkCfgEntry 9 } -- ************************************************* -- ATM link config table -- ************************************************* ss7AtmLinkCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7AtmLinkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 Atm Link Table. Information about the Atm Link(s) in MSSC are provided in this table. This table has two indices. The indices are ss7AtmVpi and ss7AtmVci (both Integer). " ::= { ss7Sig 2 } ss7AtmLinkCfgEntry OBJECT-TYPE SYNTAX Ss7AtmLinkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7AtmVpi, ss7AtmVci } ::= { ss7AtmLinkCfgTable 1 } Ss7AtmLinkCfgEntry ::= SEQUENCE { ss7AtmVpi INTEGER, ss7AtmVci INTEGER, ss7AtmLnkId INTEGER, ss7AtmXconnectId INTEGER, ss7AtmSlotId INTEGER, ss7AtmPortId INTEGER, ss7AtmChnlId INTEGER, ss7AtmTrnkId INTEGER, ss7AtmPhyType AtmIfType, ss7AtmLinkRowStatus RowStatus, ss7AtmLinkOpStatus LinkOpStatus } ss7AtmVpi OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Atmlink Virtual Path Identifier. " ::= { ss7AtmLinkCfgEntry 1 } ss7AtmVci OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Atmlink Virtual Channel Identifier. " ::= { ss7AtmLinkCfgEntry 2 } ss7AtmLnkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Atmlink Id. " ::= { ss7AtmLinkCfgEntry 3 } ss7AtmXconnectId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Xconnect Id. " ::= { ss7AtmLinkCfgEntry 4 } ss7AtmSlotId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Slot Id. " ::= { ss7AtmLinkCfgEntry 5 } ss7AtmPortId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port Id. " ::= { ss7AtmLinkCfgEntry 6 } ss7AtmChnlId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Channel Id. " ::= { ss7AtmLinkCfgEntry 7 } ss7AtmTrnkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Atm Trunk Id. " ::= { ss7AtmLinkCfgEntry 8 } ss7AtmPhyType OBJECT-TYPE SYNTAX AtmIfType ACCESS read-write STATUS mandatory DESCRIPTION "SS7 ATM Physical interface type. The value of this object could be 1) T1 (interface - t1) 2) E1 (interface - e1)." ::= { ss7AtmLinkCfgEntry 9 } ss7AtmLinkRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current ATM Status (configurational Status) of this Link. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) not" ::= { ss7AtmLinkCfgEntry 10 } ss7AtmLinkOpStatus OBJECT-TYPE SYNTAX LinkOpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this SS7 Atm Link. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) inhibit " ::= { ss7AtmLinkCfgEntry 11 } -- ************************************************* -- SS7 linkset config table -- ************************************************* ss7LinksetCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7LinksetCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 Linkset Table. Information about the Linkset(s) in MSSC are provided in this table. This table has the index ss7LinksetLinkId (Integer). " ::= { ss7Sig 3 } ss7LinksetCfgEntry OBJECT-TYPE SYNTAX Ss7LinksetCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7LinksetLinkId } ::= { ss7LinksetCfgTable 1 } Ss7LinksetCfgEntry ::= SEQUENCE { ss7LinksetLinkId INTEGER, ss7LinksetId INTEGER, ss7LinksetName NameString, ss7LinksetAdjDpc INTEGER, ss7LinksetMode Standard, ss7LinksetRowStatus RowStatus, ss7LinksetOpStatus LinkSetOpStatus } ss7LinksetLinkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Link id. Can be any integer 1-65535. " ::= { ss7LinksetCfgEntry 1 } ss7LinksetId OBJECT-TYPE SYNTAX INTEGER(1..128) ACCESS read-write STATUS mandatory DESCRIPTION "Linkset id. Can be any integer 1-128. " ::= { ss7LinksetCfgEntry 2 } ss7LinksetName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "Linkset name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters. " ::= { ss7LinksetCfgEntry 3 } ss7LinksetAdjDpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Adjacent Point Code for this Linkset (the Integer value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7LinksetCfgEntry 4 } ss7LinksetMode OBJECT-TYPE SYNTAX Standard ACCESS read-write STATUS mandatory DESCRIPTION "Linkset Type(ANSI/ITU) " ::= { ss7LinksetCfgEntry 5 } ss7LinksetRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this Link. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notread" ::= { ss7LinksetCfgEntry 6 } ss7LinksetOpStatus OBJECT-TYPE SYNTAX LinkSetOpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this Link Set. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) deactive " ::= { ss7LinksetCfgEntry 7 } -- ************************************************* -- SS7 linkset mangment table -- ************************************************* ss7LinksetMgmtTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7LinksetMgmtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 Linkset Management Table. The Management Commands for Linkset in MSSC are provided in this table. This table has the index linksetId (Integer). " ::= { ss7Sig 4 } ss7LinksetMgmtEntry OBJECT-TYPE SYNTAX Ss7LinksetMgmtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { linksetId } ::= { ss7LinksetMgmtTable 1 } Ss7LinksetMgmtEntry ::= SEQUENCE { linksetId INTEGER, linksetLevel Level, linksetMgmntCmd LinkSetControlStatus } linksetId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "SS7 Linkset Id " ::= { ss7LinksetMgmtEntry 1 } linksetLevel OBJECT-TYPE SYNTAX Level ACCESS read-write STATUS mandatory DESCRIPTION "This option deactivates the linkset at level 1 or level 2. Level 2 is for layer 2 only. The option available are: 1) Level 1 (level-1) [Default] 2) Level 2 (level-2) " ::= { ss7LinksetMgmtEntry 2 } linksetMgmntCmd OBJECT-TYPE SYNTAX LinkSetControlStatus ACCESS read-write STATUS mandatory DESCRIPTION "Management Command for Activing/DeActiving call on this linkset. The possible options are : 1) Active 2) Deactive 3) Noaction [default] " ::= { ss7LinksetMgmtEntry 3 } -- ************************************************* -- SS7 link management table -- ************************************************* ss7LinkMgmntTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7LinkMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 Link Management Table. The Management Commands for Link(s) in MSSC are provided in this table. This table has the index linkName (String). " ::= { ss7Sig 5 } ss7LinkMgmntEntry OBJECT-TYPE SYNTAX Ss7LinkMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { linkName } ::= { ss7LinkMgmntTable 1 } Ss7LinkMgmntEntry ::= SEQUENCE { linkName NameString, linkMgmntCmd LinkControlStatus } linkName OBJECT-TYPE SYNTAX NameString ACCESS read-only STATUS mandatory DESCRIPTION "SS7 Link Name " ::= { ss7LinkMgmntEntry 1 } linkMgmntCmd OBJECT-TYPE SYNTAX LinkControlStatus ACCESS read-write STATUS mandatory DESCRIPTION "Management Command for Inhibiting/UnInhibiting link. The possible options are : 1) Inhibit 2) UnInhibit 3) Noaction [default] " ::= { ss7LinkMgmntEntry 2 } -- ************************************************* -- SS7/isdn trunk group config table -- ************************************************* trunkGrpCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF TrunkGrpCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7/ISDN Trunk Group Table. The Information about Trunk Groups in MSSC are provided in this table. This table has the index trunkGrpId (Integer). " ::= { trnkGrp 1 } trunkGrpCfgEntry OBJECT-TYPE SYNTAX TrunkGrpCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { trunkGrpId } ::= { trunkGrpCfgTable 1 } TrunkGrpCfgEntry ::= SEQUENCE { trunkGrpId INTEGER, trunkGrpName DisplayString, trunkGrpCarrierId INTEGER, trunkGrpType TrnkGrpType, trunkGrpRoffName NameString, trunkGrpRoffType RoffType, trunkGrpCdrFlag CdrFlag, trunkGrpNoOfTrunks INTEGER, trunkGrpVoicePcm VoicePcm, trunkGrpRowStatus RowStatus, trunkGrpOpStatus OpStatus } trunkGrpId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Id for this trunk group. Range for Id is 1-65535. " ::= { trunkGrpCfgEntry 1 } trunkGrpName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Name of this trunk group. The Name is a string of length 8. The first two characters of Name have to be alphabhets. The next 6 charecters are numeric. An example a valid Trunk Group Name is ab123456. NOTE: This format needs to be strictly foll" ::= { trunkGrpCfgEntry 2 } trunkGrpCarrierId OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Carrier id for this trunk group. The Carrier id Field is an integer of length 4. An example for Carried Id is: 1234 NOTE: The format for sertting the Carrier Id needs to strictly followed. Failure to follow this format will result in unsucces" ::= { trunkGrpCfgEntry 3 } trunkGrpType OBJECT-TYPE SYNTAX TrnkGrpType ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Trunk group type. Possible values for Trunk group are: 1. ss7 2. isdn " ::= { trunkGrpCfgEntry 4 } trunkGrpRoffName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Remote Office Name: NOTE: Value for this object is NOT Valid if TrunkGrpType is ISDN. Only Valid For SS7 TrunkGroup. If trunkGrpType is ISDN and the USER sets the value for Remote Office Name, then this Remote Office Name will be ignored when " ::= { trunkGrpCfgEntry 5 } trunkGrpRoffType OBJECT-TYPE SYNTAX RoffType ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Remote Office Type: NOTE: Value for this object is NOT Valid if TrunkGrpType is ISDN. Remote Office Type is only Valid For SS7 TrunkGroup.If trunkGrpType is ISDN and the USER sets the value for Remote Office Type, then this value is ignored w" ::= { trunkGrpCfgEntry 6 } trunkGrpCdrFlag OBJECT-TYPE SYNTAX CdrFlag ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Cdr Flag : Possible values are: 0) noCdr -> default (No CDR file is required) 1) IC -> for Incoming calls 2) OG -> for Outgoing calls 3) BI -> for both the Incoming and outgoing calls " ::= { trunkGrpCfgEntry 7 } trunkGrpNoOfTrunks OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Denotes the Number Of Trunks that are contained in this trunk Group " ::= { trunkGrpCfgEntry 8 } trunkGrpVoicePcm OBJECT-TYPE SYNTAX VoicePcm ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { trunkGrpCfgEntry 9 } trunkGrpRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this Trunk Group. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) " ::= { trunkGrpCfgEntry 10 } trunkGrpOpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this Trunk Group. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { trunkGrpCfgEntry 11 } -- ************************************************* -- SS7 trunk config table -- ************************************************* ss7TrunkCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7TrunkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ISDN Trunk Table. The Information about ISDN Trunk(s) in MSSC are provided in this table. This table has the index ss7TrunkId (Integer). " ::= { ss7Br 1 } ss7TrunkCfgEntry OBJECT-TYPE SYNTAX Ss7TrunkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7TrunkId } ::= { ss7TrunkCfgTable 1 } Ss7TrunkCfgEntry ::= SEQUENCE { ss7TrunkId INTEGER, ss7TrunkName NameString, ss7TrunkGrpId INTEGER, ss7TrunkXconnectId INTEGER, ss7TrunkSlotId INTEGER, ss7TrunkPortId INTEGER, ss7TrunkOpc INTEGER, ss7TrunkDpc INTEGER, ss7TrunkPhyType IfType, ss7TrunkMode Standard, ss7TrunkE1MultiFrame E1MultiFrame, ss7TrunkE1CRC4 E1CRC4, ss7TrunkE1TransClk TransClkSrc, ss7TrunkDS1LineType DS1LineType, ss7TrunkDS1LineCoding DS1LineCoding, ss7TrunkDS1TransClkSrc TransClkSrc, ss7TrunkDS1LBO DS1LBO, ss7TrunkDS3LineType DS3LineType, ss7TrunkDS3TransClkSrc TransClkSrc, ss7TrunkDS3LBO DS3LBO, ss7TrunkDS3DS1LineType DS1LineType, ss7TrunkDS3DS1TransClkSrc TransClkSrc, ss7TrunkOC3TransClkSrc TransClkSrc, ss7TrunkUNCHE3TransClkSrc TransClkSrc, ss7TrunkDS3ATMLineType DS3LineType, ss7TrunkDS3ATMCellMap DS3ATMCellMap, ss7TrunkDS3ATMTransClkSrc TransClkSrc, ss7TrunkDS3ATMLBO DS3LBO, ss7TrunkRowStatus RowStatus, ss7TrunkOpStatus OpStatus } ss7TrunkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Id for the trunk. Can be any integer 1-65535. " ::= { ss7TrunkCfgEntry 1 } ss7TrunkName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "Name for the trunk. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters. " ::= { ss7TrunkCfgEntry 2 } ss7TrunkGrpId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Id of the trunk group to which the trunk belongs. Can be any integer 1-65535. " ::= { ss7TrunkCfgEntry 3 } ss7TrunkXconnectId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Xconnect id " ::= { ss7TrunkCfgEntry 4 } ss7TrunkSlotId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Slot id " ::= { ss7TrunkCfgEntry 5 } ss7TrunkPortId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port id " ::= { ss7TrunkCfgEntry 6 } ss7TrunkOpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Originating point code (the Integer value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7TrunkCfgEntry 7 } ss7TrunkDpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Destination point code ( the Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7TrunkCfgEntry 8 } ss7TrunkPhyType OBJECT-TYPE SYNTAX IfType ACCESS read-write STATUS mandatory DESCRIPTION "Physical Interface Type possible options are 1) T1 (interface-t1) 2) T3 (interface-t3) 3) Unchannelized T3 (interface-ut3) 4) OC3 (interface-oc3) 5) Unchannelized T3 with compression (interface-ut3cp) 6) OC3 with compression (interface-oc3cp) 7) E" ::= { ss7TrunkCfgEntry 9 } ss7TrunkMode OBJECT-TYPE SYNTAX Standard ACCESS read-write STATUS mandatory DESCRIPTION "Trunk mode - ANSI/ITU " ::= { ss7TrunkCfgEntry 10 } ss7TrunkE1MultiFrame OBJECT-TYPE SYNTAX E1MultiFrame ACCESS read-write STATUS mandatory DESCRIPTION "E1 multiFrame Type possible options are 1) CAS(1) 2) CCS(2)" ::= { ss7TrunkCfgEntry 11 } ss7TrunkE1CRC4 OBJECT-TYPE SYNTAX E1CRC4 ACCESS read-write STATUS mandatory DESCRIPTION "E1 Cyclic Redundancy Code, possible options are 1) enabled(1) 2) disable(2)" ::= { ss7TrunkCfgEntry 12 } ss7TrunkE1TransClk OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "E1 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { ss7TrunkCfgEntry 13 } ss7TrunkDS1LineType OBJECT-TYPE SYNTAX DS1LineType ACCESS read-write STATUS mandatory DESCRIPTION "DS1 Line Type possible options are 1) esF(1) 2) d4(2)" ::= { ss7TrunkCfgEntry 14 } ss7TrunkDS1LineCoding OBJECT-TYPE SYNTAX DS1LineCoding ACCESS read-write STATUS mandatory DESCRIPTION "DS1 Line Coding, possible options are 1) b8zs(1) 2) ami(2)" ::= { ss7TrunkCfgEntry 15 } ss7TrunkDS1TransClkSrc OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "DS1 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { ss7TrunkCfgEntry 16 } ss7TrunkDS1LBO OBJECT-TYPE SYNTAX DS1LBO ACCESS read-write STATUS mandatory DESCRIPTION "DS1 Line Build Out, possible options are 1) upTo133Feet(1) 2) upTo266Feet(2) 3) upTo399Feet(3) 4) upTo533Feet(4) 5) upTo655Feet(5) 6) negative7_5Db(6) 7) negative15Db(7) 8) negative22_5Db(8)" ::= { ss7TrunkCfgEntry 17 } ss7TrunkDS3LineType OBJECT-TYPE SYNTAX DS3LineType ACCESS read-write STATUS mandatory DESCRIPTION "DS3 Line Type possible options are 1) cbitParity(1) 2) clearChannel(2)" ::= { ss7TrunkCfgEntry 18 } ss7TrunkDS3TransClkSrc OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "DS3 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { ss7TrunkCfgEntry 19 } ss7TrunkDS3LBO OBJECT-TYPE SYNTAX DS3LBO ACCESS read-write STATUS mandatory DESCRIPTION "DS3 Line Build Out possible options are 1) short(1) 2) long(2)" ::= { ss7TrunkCfgEntry 20 } ss7TrunkDS3DS1LineType OBJECT-TYPE SYNTAX DS1LineType ACCESS read-write STATUS mandatory DESCRIPTION "DS3DS1 Line Type possible options are 1) esF(1) 2) d4(2)" ::= { ss7TrunkCfgEntry 21 } ss7TrunkDS3DS1TransClkSrc OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "DS3DS1ansmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { ss7TrunkCfgEntry 22 } ss7TrunkOC3TransClkSrc OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "OC3 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { ss7TrunkCfgEntry 23 } ss7TrunkUNCHE3TransClkSrc OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "UNCHANNELIZED E3 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { ss7TrunkCfgEntry 24 } ss7TrunkDS3ATMLineType OBJECT-TYPE SYNTAX DS3LineType ACCESS read-write STATUS mandatory DESCRIPTION "DS3-ATM Line Type possible options are 1) cbitParity(1) 2) clearChannel(2)" ::= { ss7TrunkCfgEntry 25 } ss7TrunkDS3ATMCellMap OBJECT-TYPE SYNTAX DS3ATMCellMap ACCESS read-write STATUS mandatory DESCRIPTION "DS3-ATM Cell Mapping, possible options are 1) plcp(1) 2) directMapping(2)" ::= { ss7TrunkCfgEntry 26 } ss7TrunkDS3ATMTransClkSrc OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "DS3-ATM transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { ss7TrunkCfgEntry 27 } ss7TrunkDS3ATMLBO OBJECT-TYPE SYNTAX DS3LBO ACCESS read-write STATUS mandatory DESCRIPTION "DS3-ATM Line Build Out possible options are 1) short(1) 2) long(2)" ::= { ss7TrunkCfgEntry 28 } ss7TrunkRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this SS7 Trunk. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) no" ::= { ss7TrunkCfgEntry 29 } ss7TrunkOpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this SS7 Trunk. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { ss7TrunkCfgEntry 30 } -- ************************************************* -- SS7 circuit config table -- ************************************************* ss7CktCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7CktCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 Circuit Table. The Information about SS7 Circuit(s) in MSSC are provided in this table. This table has two indices: ss7CktTrunkId and ss7CktChnlId (both Integer). " ::= { ss7Br 2 } ss7CktCfgEntry OBJECT-TYPE SYNTAX Ss7CktCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7CktTrunkId, ss7CktChnlId } ::= { ss7CktCfgTable 1 } Ss7CktCfgEntry ::= SEQUENCE { ss7CktTrunkId INTEGER, ss7CktChnlId INTEGER, ss7CktId INTEGER, ss7CktDpc INTEGER, ss7CktCic INTEGER, ss7CktDir Direction, ss7CktPriority INTEGER, ss7CktT3 INTEGER, ss7CktT12 INTEGER, ss7CktT13 INTEGER, ss7CktT14 INTEGER, ss7CktT15 INTEGER, ss7CktT16 INTEGER, ss7CktT17 INTEGER, ss7CktTVal INTEGER, ss7CktRowStatus CktRowStatus, ss7CktOpStatus CktOpStatus } ss7CktTrunkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "User Assigned Trunk id. " ::= { ss7CktCfgEntry 1 } ss7CktChnlId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "User Assigned Channel id " ::= { ss7CktCfgEntry 2 } ss7CktId OBJECT-TYPE SYNTAX INTEGER(1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "Circuit id. The Id assingned to each of the circuits for a particular Trunk. " ::= { ss7CktCfgEntry 3 } ss7CktDpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7CktCfgEntry 4 } ss7CktCic OBJECT-TYPE SYNTAX INTEGER(1..16383) ACCESS read-write STATUS mandatory DESCRIPTION "Circuit identifier code. Can be any integer from 1) 1-4095 for ITU 2) 1-16383 for ANSI " ::= { ss7CktCfgEntry 5 } ss7CktDir OBJECT-TYPE SYNTAX Direction ACCESS read-write STATUS mandatory DESCRIPTION "Traffic direction: Possible options are : 1) IN 2) OUT 3) BOTH " ::= { ss7CktCfgEntry 6 } ss7CktPriority OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Traffic priority " ::= { ss7CktCfgEntry 7 } ss7CktT3 OBJECT-TYPE SYNTAX INTEGER(0..120) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T3 timer. Default Value is 0 milliSeconds " DEFVAL { 0 } ::= { ss7CktCfgEntry 8 } ss7CktT12 OBJECT-TYPE SYNTAX INTEGER(4000..60000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T12 timer - blocking sent. Default Value is 40 milliSeconds " DEFVAL { 4000 } ::= { ss7CktCfgEntry 9 } ss7CktT13 OBJECT-TYPE SYNTAX INTEGER(60..900) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T13 timer - initial blocking sent. Default Value is 600 milliSeconds " DEFVAL { 60 } ::= { ss7CktCfgEntry 10 } ss7CktT14 OBJECT-TYPE SYNTAX INTEGER(4000..60000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T14 timer - unblocking sent. Default Value is 40 milliSeconds " DEFVAL { 4000 } ::= { ss7CktCfgEntry 11 } ss7CktT15 OBJECT-TYPE SYNTAX INTEGER(60..900) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T15 timer - initial unblocking sent. Default Value is 600 milliSeconds " DEFVAL { 60 } ::= { ss7CktCfgEntry 12 } ss7CktT16 OBJECT-TYPE SYNTAX INTEGER(4000..60000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T16 timer - reset sent. Default Value is 40 milliSeconds " DEFVAL { 4000 } ::= { ss7CktCfgEntry 13 } ss7CktT17 OBJECT-TYPE SYNTAX INTEGER(60..900) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T17 timer - initial reset sent. Default Value is 600 milliSeconds " DEFVAL { 60 } ::= { ss7CktCfgEntry 14 } ss7CktTVal OBJECT-TYPE SYNTAX INTEGER(10000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "TVal timer - initial reset sent. Default Value is 100 milliSeconds " DEFVAL { 10000 } ::= { ss7CktCfgEntry 15 } ss7CktRowStatus OBJECT-TYPE SYNTAX CktRowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this SS7 Circuit. To Configure this circuit, the only option is 'CREATEANDWAIT'. To Delete this circuit, the only option is 'DESTROY'. To Modify any of the Circuit Timers, the only option is 'MODIFYTIMER'. Fo" ::= { ss7CktCfgEntry 16 } ss7CktOpStatus OBJECT-TYPE SYNTAX CktOpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this SS7 Circuit. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) block " ::= { ss7CktCfgEntry 17 } -- ************************************************* -- SS7 Cic timer table -- ************************************************* ss7CICTimerTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7CicTmrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 Circuit CIC Timer Table. The Information about SS7 Circuit(s) Timers in MSSC are provided in this table.User can Modify any Timer(s) in this table. This table has two indices: ss7CktTmrDpc and ss7CktTmrCic (both Integer). " ::= { ss7Br 3 } ss7CicTmrEntry OBJECT-TYPE SYNTAX Ss7CicTmrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7CktTmrDpc, ss7CktTmrCic } ::= { ss7CICTimerTable 1 } Ss7CicTmrEntry ::= SEQUENCE { ss7CktTmrDpc INTEGER, ss7CktTmrCic INTEGER, ss7CktTmrT3 INTEGER, ss7CktTmrT12 INTEGER, ss7CktTmrT13 INTEGER, ss7CktTmrT14 INTEGER, ss7CktTmrT15 INTEGER, ss7CktTmrT16 INTEGER, ss7CktTmrT17 INTEGER, ss7CktTmrTVal INTEGER, ss7CktTmrRowStatus ModifyTmrStatus } ss7CktTmrDpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7CicTmrEntry 1 } ss7CktTmrCic OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Circuit identifier code. Can be any integer 1-65535. " ::= { ss7CicTmrEntry 2 } ss7CktTmrT3 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T3 timer. Default Value is 0 milliSeconds " DEFVAL { 0 } ::= { ss7CicTmrEntry 3 } ss7CktTmrT12 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T12 timer - blocking sent. Default Value is 40 milliSeconds " DEFVAL { 40 } ::= { ss7CicTmrEntry 4 } ss7CktTmrT13 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T13 timer - initial blocking sent. Default Value is 600 milliSeconds " DEFVAL { 600 } ::= { ss7CicTmrEntry 5 } ss7CktTmrT14 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T14 timer - unblocking sent. Default Value is 40 milliSeconds " DEFVAL { 40 } ::= { ss7CicTmrEntry 6 } ss7CktTmrT15 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T15 timer - initial unblocking sent. Default Value is 600 milliSeconds " DEFVAL { 600 } ::= { ss7CicTmrEntry 7 } ss7CktTmrT16 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T16 timer - reset sent. Default Value is 40 milliSeconds " DEFVAL { 40 } ::= { ss7CicTmrEntry 8 } ss7CktTmrT17 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T17 timer - initial reset sent. Default Value is 600 milliSeconds " DEFVAL { 600 } ::= { ss7CicTmrEntry 9 } ss7CktTmrTVal OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "TVal timer - initial reset sent. Default Value is 100 milliSeconds " DEFVAL { 100 } ::= { ss7CicTmrEntry 10 } ss7CktTmrRowStatus OBJECT-TYPE SYNTAX ModifyTmrStatus ACCESS read-write STATUS mandatory DESCRIPTION "This is a command to MODIFY a Timer. A 'GET' operation on this object will display the default value [no action]. The possible option for 'SET' operation is: 1)modify " ::= { ss7CicTmrEntry 11 } -- ************************************************* -- SS7 broadband circuit table -- ************************************************* ss7BCktCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7BCktCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 B-Circuit Table. The Information about SS7 B-Circuit(s) in MSSC are provided in this table.This table has two indices: ss7BCktVpi and ss7BCktVci (both Integer). " ::= { ss7Br 4 } ss7BCktCfgEntry OBJECT-TYPE SYNTAX Ss7BCktCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7BCktVpi, ss7BCktVci } ::= { ss7BCktCfgTable 1 } Ss7BCktCfgEntry ::= SEQUENCE { ss7BCktVpi INTEGER, ss7BCktVci INTEGER, ss7BCktTrunkId INTEGER, ss7BCktDpc INTEGER, ss7BCktCic INTEGER, ss7BCktDir Direction, ss7BCktPriority INTEGER, ss7BCktT3 INTEGER, ss7BCktT12 INTEGER, ss7BCktT13 INTEGER, ss7BCktT14 INTEGER, ss7BCktT15 INTEGER, ss7BCktT16 INTEGER, ss7BCktT17 INTEGER, ss7BCktTVal INTEGER, ss7BCktRowStatus CktRowStatus, ss7BCktOpStatus CktOpStatus } ss7BCktVpi OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Broadband Virtual Path Indentifier. Can be any integer 1-65535. " ::= { ss7BCktCfgEntry 1 } ss7BCktVci OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Broadband Virtual Channel Identifier. Can be any integer 1-65535. " ::= { ss7BCktCfgEntry 2 } ss7BCktTrunkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Trunk id. " ::= { ss7BCktCfgEntry 3 } ss7BCktDpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Broadband Circuit Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7BCktCfgEntry 4 } ss7BCktCic OBJECT-TYPE SYNTAX INTEGER(1..16383) ACCESS read-write STATUS mandatory DESCRIPTION "Circuit identifier code. Can be any integer from : 1) 1-16383 for ANSI 2) 1-4095 for ITU " ::= { ss7BCktCfgEntry 5 } ss7BCktDir OBJECT-TYPE SYNTAX Direction ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Traffic direction. Possible Values are: 1) in 2) out 3) both " ::= { ss7BCktCfgEntry 6 } ss7BCktPriority OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Traffic priority " ::= { ss7BCktCfgEntry 7 } ss7BCktT3 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T3 timer. Default Value is 0 milliSeconds " DEFVAL { 0 } ::= { ss7BCktCfgEntry 8 } ss7BCktT12 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T12 timer - blocking sent. Default Value is 40 milliSeconds " DEFVAL { 40 } ::= { ss7BCktCfgEntry 9 } ss7BCktT13 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T13 timer - initial blocking sent. Default Value is 600 milliSeconds " DEFVAL { 600 } ::= { ss7BCktCfgEntry 10 } ss7BCktT14 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T14 timer - unblocking sent. Default Value is 40 milliSeconds " DEFVAL { 40 } ::= { ss7BCktCfgEntry 11 } ss7BCktT15 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T15 timer - initial unblocking sent. Default Value is 600 milliSeconds " DEFVAL { 600 } ::= { ss7BCktCfgEntry 12 } ss7BCktT16 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T16 timer - reset sent. Default Value is 40 milliSeconds " DEFVAL { 40 } ::= { ss7BCktCfgEntry 13 } ss7BCktT17 OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T17 timer - initial reset sent. Default Value is 600 milliSeconds " DEFVAL { 600 } ::= { ss7BCktCfgEntry 14 } ss7BCktTVal OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "TVal timer - initial reset sent. Default Value is 100 milliSeconds " DEFVAL { 100 } ::= { ss7BCktCfgEntry 15 } ss7BCktRowStatus OBJECT-TYPE SYNTAX CktRowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this SS7 B-Circuit. To Configure this circuit, the only option is 'CREATEANDWAIT'. To Modify any of the timers the only option is 'MODIFYTIMER' . To Delete this circuit, the only option is 'DESTROY'. For the " ::= { ss7BCktCfgEntry 16 } ss7BCktOpStatus OBJECT-TYPE SYNTAX CktOpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this SS7 B-Circuit. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) block " ::= { ss7BCktCfgEntry 17 } -- ************************************************* -- SS7 circuit management Group -- ************************************************* ss7CktMgmntGroup OBJECT IDENTIFIER ::= { ss7Br 5 } -- ************************************************* -- SS7 circuit Managmant group -- ************************************************* ss7CktMgmntTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7CktMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 Circuit Management Table. The Management Commands for SS7 Circuits(s) in MSSC are provided in this table. This table has two indices: ss7CktMgmntTrnkId and ss7CktMgmntChnlId (both Integer). " ::= { ss7CktMgmntGroup 1 } ss7CktMgmntEntry OBJECT-TYPE SYNTAX Ss7CktMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7CktMgmntTrnkId, ss7CktMgmntChnlId } ::= { ss7CktMgmntTable 1 } Ss7CktMgmntEntry ::= SEQUENCE { ss7CktMgmntTrnkId INTEGER, ss7CktMgmntChnlId INTEGER, ss7CktMgmntRepNum INTEGER, ss7CktMgmntCmd BlockOperation } ss7CktMgmntTrnkId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk id. " ::= { ss7CktMgmntEntry 1 } ss7CktMgmntChnlId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Channel id " ::= { ss7CktMgmntEntry 2 } ss7CktMgmntRepNum OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Repeat Number for this operation. This option will allow consecutive CIC to be reset " ::= { ss7CktMgmntEntry 3 } ss7CktMgmntCmd OBJECT-TYPE SYNTAX BlockOperation ACCESS read-write STATUS mandatory DESCRIPTION "Management Command for Blocking/Unblocking any call setup on the specified channel. The option of repnum is provided to allow consecutive CIC to be blocked/unblocked The possible options are : 1) Block 2) UnBlock 3) Noaction [default] " ::= { ss7CktMgmntEntry 4 } -- ************************************************* -- SS7b Cic Management table -- ************************************************* ss7CICMgmntTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7CICMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 Circuit CIC Management Table. The Management Commands for SS7 Circuits(s) in MSSC are provided in this table. This table has two indices: ss7CktMgmtDPC and ss7CktMgmtCIC (both Integer). " ::= { ss7CktMgmntGroup 2 } ss7CICMgmntEntry OBJECT-TYPE SYNTAX Ss7CICMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7CktMgmtDPC, ss7CktMgmtCIC } ::= { ss7CICMgmntTable 1 } Ss7CICMgmntEntry ::= SEQUENCE { ss7CktMgmtDPC INTEGER, ss7CktMgmtCIC INTEGER, ss7CktRepNum INTEGER, ss7CicRange INTEGER, ss7CICMgmntCmd CircuitControlStatus } ss7CktMgmtDPC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7CICMgmntEntry 1 } ss7CktMgmtCIC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Circuit identifier code. Can be any integer from 1) 1-4095 for ITU 2) 1-16383 for ANSI " ::= { ss7CICMgmntEntry 2 } ss7CktRepNum OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Repeat Number for this operation. This option will allow consecutive CIC to be reset " ::= { ss7CICMgmntEntry 3 } ss7CicRange OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Range for this operation. This option will allow consecutive CIC to be reset " ::= { ss7CICMgmntEntry 4 } ss7CICMgmntCmd OBJECT-TYPE SYNTAX CircuitControlStatus ACCESS read-write STATUS mandatory DESCRIPTION "Management Command for Blocking/Unblocking any call setup on the specified channel. The option of repnum is provided to allow consecutive CIC to be blocked/unblocked The possible options are : 1) Block 2) UnBlock [default] " ::= { ss7CICMgmntEntry 5 } -- ************************************************* -- Mtp2 timer Configuration starts here -- ************************************************* mtp2LinkTmrCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF Mtp2LinkTmrCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "MTP2 Link Timer Table. The Information about MTP2 Link Timers in MSSC are provided in this table. User can Modify Timer(s) from this table. This table has one index: mtp2LinkId (Integer). " ::= { mtp2 1 } mtp2LinkTmrCfgEntry OBJECT-TYPE SYNTAX Mtp2LinkTmrCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { mtp2LinkId } ::= { mtp2LinkTmrCfgTable 1 } Mtp2LinkTmrCfgEntry ::= SEQUENCE { mtp2LinkId INTEGER, mtp2T1 INTEGER, mtp2T2 INTEGER, mtp2T3 INTEGER, mtp2T4n INTEGER, mtp2T4e INTEGER, mtp2T5 INTEGER, mtp2T6 INTEGER, mtp2T7 INTEGER, mtp2RowStatus TmrRowStatus, mtp2OpStatus OpStatus } mtp2LinkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Link id. Can be any integer 1-65535. " ::= { mtp2LinkTmrCfgEntry 1 } mtp2T1 OBJECT-TYPE SYNTAX INTEGER(13000..50000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "t1 timer - for aligned ready condition GR-606-CORE, ISSUE 1, June 1994. Default Value is 13000 milliSeconds " DEFVAL { 13000 } ::= { mtp2LinkTmrCfgEntry 2 } mtp2T2 OBJECT-TYPE SYNTAX INTEGER(5000..50000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "t2 timer - Timer for out-of-alignment GR-606-CORE, ISSUE 1, June 1994. Default Value is 11500 milliSeconds " DEFVAL { 11500 } ::= { mtp2LinkTmrCfgEntry 3 } mtp2T3 OBJECT-TYPE SYNTAX INTEGER(1000..15000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "t3 timer - Timer for aligned condition GR-606-CORE, ISSUE 1, June 1994. Default Value is 11500 milliSeconds " DEFVAL { 1000 } ::= { mtp2LinkTmrCfgEntry 4 } mtp2T4n OBJECT-TYPE SYNTAX INTEGER(2070..9500) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "t4n timer - Normal proving period GR-606-CORE, ISSUE 1, June 1994. Default Value is 2000 milliSeconds " DEFVAL { 2070 } ::= { mtp2LinkTmrCfgEntry 5 } mtp2T4e OBJECT-TYPE SYNTAX INTEGER(400..600) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "t4e timer - Emergency proving period GR-606-CORE, ISSUE 1, June 1994. Default Value is 500 milliSeconds " DEFVAL { 400 } ::= { mtp2LinkTmrCfgEntry 6 } mtp2T5 OBJECT-TYPE SYNTAX INTEGER(80..120) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "t5 timer - Busy status transmission interval GR-606-CORE, ISSUE 1, June 1994. Default Value is 100 milliSeconds " DEFVAL { 80 } ::= { mtp2LinkTmrCfgEntry 7 } mtp2T6 OBJECT-TYPE SYNTAX INTEGER(3000..6000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "t6 timer - Supervision of remote congestion timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 3000 milliSeconds " DEFVAL { 3000 } ::= { mtp2LinkTmrCfgEntry 8 } mtp2T7 OBJECT-TYPE SYNTAX INTEGER(500..2000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "t7 timer - Excessive delay of ack GR-606-CORE, ISSUE 1, June 1994. Default Value is 500 milliSeconds " DEFVAL { 500 } ::= { mtp2LinkTmrCfgEntry 9 } mtp2RowStatus OBJECT-TYPE SYNTAX TmrRowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this MTP2 Link Timer. To Modify any Timer for this link, the only option is 'MODIFYTIMER'. For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notready 4) modified 5) up 6) down" ::= { mtp2LinkTmrCfgEntry 10 } mtp2OpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this MTP2 Link Timer. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { mtp2LinkTmrCfgEntry 11 } -- ************************************************* -- mtp3 general timer configuration starts here -- ************************************************* mtp3T15 OBJECT-TYPE SYNTAX INTEGER(2000..3000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T15 timer - Signal route set congestion test interval GR-606-CORE, ISSUE 1, June 1994. Default Value is 3000 milliSeconds " DEFVAL { 2000 } ::= { mtp3GenTmrCfgGroup 1 } mtp3T16 OBJECT-TYPE SYNTAX INTEGER(1400..2000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T16 timer - Transfer controlled update GR-606-CORE, ISSUE 1, June 1994. Default Value is 1400 milliSeconds " DEFVAL { 2000 } ::= { mtp3GenTmrCfgGroup 2 } mtp3T18 OBJECT-TYPE SYNTAX INTEGER(0..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T18 timer - Timer for links to become available. Not Applicable to ANSI. Default Value is 1400 milliSeconds " DEFVAL { 600 } ::= { mtp3GenTmrCfgGroup 3 } mtp3T19 OBJECT-TYPE SYNTAX INTEGER(67000..69000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T19 timer - Timer to receive all traffic restart. Not Applicable to ANSI. Default Value is 0 " DEFVAL { 67000 } ::= { mtp3GenTmrCfgGroup 4 } mtp3T20 OBJECT-TYPE SYNTAX INTEGER(59000..61000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T20 timer - BroadCast traffic restart interval. Not Applicable to ANSI. " DEFVAL { 590000 } ::= { mtp3GenTmrCfgGroup 5 } mtp3T21 OBJECT-TYPE SYNTAX INTEGER(63000..65000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T21 timer - Interval to restart traffic route through adjacent SP " DEFVAL { 63000 } ::= { mtp3GenTmrCfgGroup 6 } mtp3T26 OBJECT-TYPE SYNTAX INTEGER(12000..15000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T26 timer - Timer at restarting SP waiting to repeat TRW GR-606-CORE, ISSUE 1, June 1994. Default Value is 13500 milliSeconds " DEFVAL { 12000 } ::= { mtp3GenTmrCfgGroup 7 } mtp3T30 OBJECT-TYPE SYNTAX INTEGER(30000..35000) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "T30 timer - Route Instance timer " DEFVAL { 30000 } ::= { mtp3GenTmrCfgGroup 8 } mtp3GenTmrRowStatus OBJECT-TYPE SYNTAX ModifyTmrStatus ACCESS read-write STATUS mandatory DESCRIPTION "This is a command to MODIFY a Timer. A 'GET' operation on this object will display the default value [no action]. The possible option for 'SET' operation is: 1)modify " ::= { mtp3GenTmrCfgGroup 9 } -- ************************************************* -- mtp3 link configuration table -- ************************************************* mtp3LinkCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF Mtp3LinkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "MTP3 Link Timer Table. The Information about MTP3 Link Timers in MSSC are provided in this table. User can Modify Timer(s) from this table. This table has one index: mtp3LinkId (Integer). " ::= { mtp3 2 } mtp3LinkCfgEntry OBJECT-TYPE SYNTAX Mtp3LinkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { mtp3LinkId } ::= { mtp3LinkCfgTable 1 } Mtp3LinkCfgEntry ::= SEQUENCE { mtp3LinkId INTEGER, mtp3T1 INTEGER, mtp3T2 INTEGER, mtp3T3 INTEGER, mtp3T4 INTEGER, mtp3T5 INTEGER, mtp3T6 INTEGER, mtp3T7 INTEGER, mtp3T12 INTEGER, mtp3T13 INTEGER, mtp3T14 INTEGER, mtp3T17 INTEGER, mtp3T22 INTEGER, mtp3T23 INTEGER, mtp3T24 INTEGER, mtp3T31 INTEGER, mtp3T32 INTEGER, mtp3T33 INTEGER, mtp3T34 INTEGER, mtp3T35 INTEGER, mtp3T36 INTEGER, mtp3T37 INTEGER, mtp3TFLC INTEGER, mtp3TBND INTEGER, mtp3RowStatus TmrRowStatus, mtp3OpStatus OpStatus } mtp3LinkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Link id GR-606-CORE, ISSUE 1, June 1994 " ::= { mtp3LinkCfgEntry 1 } mtp3T1 OBJECT-TYPE SYNTAX INTEGER(500..1200) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T1 timer - Transmission delay following changeover GR-606-CORE, ISSUE 1, June 1994. Default Value is 500 milliSeconds " DEFVAL { 1000 } ::= { mtp3LinkCfgEntry 2 } mtp3T2 OBJECT-TYPE SYNTAX INTEGER(700..2000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T2 timer - changeover ack timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 700 milliSeconds " DEFVAL { 1000 } ::= { mtp3LinkCfgEntry 3 } mtp3T3 OBJECT-TYPE SYNTAX INTEGER(500..1200) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T3 timer - Transmission delay following changeback GR-606-CORE, ISSUE 1, June 1994. Default Value is 500 milliSeconds " DEFVAL { 1000 } ::= { mtp3LinkCfgEntry 4 } mtp3T4 OBJECT-TYPE SYNTAX INTEGER(500..1200) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T4 timer - Changeback ack timer (first attempt) GR-606-CORE, ISSUE 1, June 1994. Default is 500 milliSeconds " DEFVAL { 1000 } ::= { mtp3LinkCfgEntry 5 } mtp3T5 OBJECT-TYPE SYNTAX INTEGER(500..1200) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T5 timer - Changeback ack timer (subsequent attempt) GR-606-CORE, ISSUE 1, June 1994. Default is 500 milliSeconds " DEFVAL { 1000 } ::= { mtp3LinkCfgEntry 6 } mtp3T6 OBJECT-TYPE SYNTAX INTEGER(500..1200) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T6 timer - Controlled rerouting transmission delay GR-606-CORE, ISSUE 1, June 1994. Default Value is 500 milliSeconds " DEFVAL { 500 } ::= { mtp3LinkCfgEntry 7 } mtp3T7 OBJECT-TYPE SYNTAX INTEGER(500..1200) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "T7 Timer - Link connection ack timer " ::= { mtp3LinkCfgEntry 8 } mtp3T12 OBJECT-TYPE SYNTAX INTEGER(800..1500) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T12 timer - Uninhibit acknowledge timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 1000 milliSeconds " DEFVAL { 1000 } ::= { mtp3LinkCfgEntry 9 } mtp3T13 OBJECT-TYPE SYNTAX INTEGER(800..1500) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T13 timer - Forced uninhibit ack timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 1000 milliSeconds. " DEFVAL { 1000 } ::= { mtp3LinkCfgEntry 10 } mtp3T14 OBJECT-TYPE SYNTAX INTEGER(2000..3000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T14 timer - Inhibit ack timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 3000 milliSeconds " DEFVAL { 3000 } ::= { mtp3LinkCfgEntry 11 } mtp3T17 OBJECT-TYPE SYNTAX INTEGER(800..1500) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T17 timer - Timing to restart of initial alignment GR-606-CORE, ISSUE 1, June 1994. Default Value is 1000 milliSeconds " DEFVAL { 1000 } ::= { mtp3LinkCfgEntry 12 } mtp3T22 OBJECT-TYPE SYNTAX INTEGER(180..360) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T20 timer - Waiting to repeat local inhibit test. Default Value is 10000 milliSeconds " DEFVAL { 180 } ::= { mtp3LinkCfgEntry 13 } mtp3T23 OBJECT-TYPE SYNTAX INTEGER(180..360) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T21 timer - Waiting to repeat remote inhibit test. Default Value is 10000 milliSeconds " DEFVAL { 180 } ::= { mtp3LinkCfgEntry 14 } mtp3T24 OBJECT-TYPE SYNTAX INTEGER(5000..5000) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "T24 timer - Stabilizing timer. " DEFVAL { 5000 } ::= { mtp3LinkCfgEntry 15 } mtp3T31 OBJECT-TYPE SYNTAX INTEGER(10..120) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T31 timer - Timer to detect a link in false link congestion. GR-606-CORE, ISSUE 1, June 1994. Default Value is 30000 milliSeconds " DEFVAL { 120 } ::= { mtp3LinkCfgEntry 16 } mtp3T32 OBJECT-TYPE SYNTAX INTEGER(4..12) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T32 timer - SLT timer " DEFVAL { 4 } ::= { mtp3LinkCfgEntry 17 } mtp3T33 OBJECT-TYPE SYNTAX INTEGER(60..600) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T33 timer - Timer to detect a link in false link congestion. GR-606-CORE, ISSUE 1, June 1994. Default Value is 30000 milliSeconds " DEFVAL { 120 } ::= { mtp3LinkCfgEntry 18 } mtp3T34 OBJECT-TYPE SYNTAX INTEGER(30..90) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T34 timer - Timer to detect a link in false link congestion. GR-606-CORE, ISSUE 1, June 1994. Default Value is 30000 milliSeconds " DEFVAL { 30 } ::= { mtp3LinkCfgEntry 19 } mtp3T35 OBJECT-TYPE SYNTAX INTEGER(10..120) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T35 timer - periodic signalling link test timer GR-606-CORE, ISSUE 1, June 1994. Default Value is 30000 milliSeconds " DEFVAL { 120 } ::= { mtp3LinkCfgEntry 20 } mtp3T36 OBJECT-TYPE SYNTAX INTEGER(60..600) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T36 timer - Probation timer for link oscillation. Not in bellcore. Default Value is 30000 milliSeconds " DEFVAL { 120 } ::= { mtp3LinkCfgEntry 21 } mtp3T37 OBJECT-TYPE SYNTAX INTEGER(5..120) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T37 timer - Suspension Timer for link oscillation. Not in bellcore. Default Value is 30000 milliSeconds " DEFVAL { 120 } ::= { mtp3LinkCfgEntry 22 } mtp3TFLC OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "TFLC timer - Flow control request timer. Not in bellcore. " DEFVAL { 5000 } ::= { mtp3LinkCfgEntry 23 } mtp3TBND OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "TBND timer - Bind confirm wait timer. Not in bellcore. " DEFVAL { 20000 } ::= { mtp3LinkCfgEntry 24 } mtp3RowStatus OBJECT-TYPE SYNTAX TmrRowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this MTP3 Link Timer. To Modify any Timer for this link, the only option is 'MODIFYTIMER'. For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notready 4) modified 5) up 6) down" ::= { mtp3LinkCfgEntry 25 } mtp3OpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this MTP3 Link Timer. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { mtp3LinkCfgEntry 26 } -- ************************************************* -- ISUP general Timer configuration Group -- ************************************************* isupTimerCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF IsupTimerCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Isup Timer Table. The Information about ISUPTimers in MSSC are provided in this table. User can Modify Timer(s) from this table. This table has one index: isupTmrSS7Type (TimerType). " ::= { isup 1 } isupTimerCfgEntry OBJECT-TYPE SYNTAX IsupTimerCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { isupTimerType } ::= { isupTimerCfgTable 1 } IsupTimerCfgEntry ::= SEQUENCE { isupTimerType TimerType, isupTmrT1 INTEGER, isupTmrT2 INTEGER, isupTmrT5 INTEGER, isupTmrT6 INTEGER, isupTmrT7 INTEGER, isupTmrT8 INTEGER, isupTmrT9 INTEGER, isupTmrT18 INTEGER, isupTmrT19 INTEGER, isupTmrT20 INTEGER, isupTmrT21 INTEGER, isupTmrT22 INTEGER, isupTmrT23 INTEGER, isupTmrT27 INTEGER, isupTmrT28 INTEGER, isupTmrT31 INTEGER, isupTmrT33 INTEGER, isupTmrT34 INTEGER, isupTmrT36 INTEGER, isupTmrTCCR INTEGER, isupTmrTEX INTEGER, isupTmrTCRM INTEGER, isupTmrTCRA INTEGER, isupTmrTCCRt INTEGER, isupTmrTECt INTEGER, isupTmrTGTCHG INTEGER, isupTmrTGRES INTEGER, isupTmrTFGR INTEGER, isupTmrTRELRSP INTEGER, isupTmrTFNLRELRS INTEGER, isupTimerRowStatus ModifyTmrStatus } isupTimerType OBJECT-TYPE SYNTAX TimerType(1..2) ACCESS read-write STATUS mandatory DESCRIPTION "Index for this IsupTimer Table, is an enumerated data type ansi(1), itu(2)" ::= { isupTimerCfgEntry 1 } isupTmrT1 OBJECT-TYPE SYNTAX INTEGER(4000..60000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T1 timer - release sent, GR-246-CORE, Issue 2, December 1997. Default Value is 4000 milliSeconds " DEFVAL { 4000 } ::= { isupTimerCfgEntry 2 } isupTmrT2 OBJECT-TYPE SYNTAX INTEGER(0..180) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T2 timer - suspend received, GR-246-CORE, Issue 2, December 1997. Default Value is 0 milliSeconds " DEFVAL { 180 } ::= { isupTimerCfgEntry 3 } isupTmrT5 OBJECT-TYPE SYNTAX INTEGER(60..900) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T5 timer - initial release sent GR-246-CORE, Issue 2, December 1997. Default Value is 60000 milliSeconds " DEFVAL { 300 } ::= { isupTimerCfgEntry 4 } isupTmrT6 OBJECT-TYPE SYNTAX INTEGER(10000..32000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T6 timer - suspend received GR-246-CORE, Issue 2, December 1997. Default Value is 10000 milliSeconds " DEFVAL { 10000 } ::= { isupTimerCfgEntry 5 } isupTmrT7 OBJECT-TYPE SYNTAX INTEGER(20000..30000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T7 timer - latest address sent GR-246-CORE, Issue 2, December 1997. Default Value is 20000 milliSeconds " DEFVAL { 20000 } ::= { isupTimerCfgEntry 6 } isupTmrT8 OBJECT-TYPE SYNTAX INTEGER(10000..15000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T8 - timer initial address received GR-246-CORE, Issue 2, December 1997. Default Value is 10000 milliSeconds " DEFVAL { 10000 } ::= { isupTimerCfgEntry 7 } isupTmrT9 OBJECT-TYPE SYNTAX INTEGER(120..240) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T9 timer - latest address sent after ACM GR-246-CORE, Issue 2, December 1997. Default Value is 120000 milliSeconds " DEFVAL { 120 } ::= { isupTimerCfgEntry 8 } isupTmrT18 OBJECT-TYPE SYNTAX INTEGER(4000..60000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T18 timer - group blocking sent GR-246-CORE, Issue 2, December 1997. Default Value is 4000 milliSeconds " DEFVAL { 15000 } ::= { isupTimerCfgEntry 9 } isupTmrT19 OBJECT-TYPE SYNTAX INTEGER(60..900) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T19 timer - initial group blocking sent GR-246-CORE, Issue 2, December 1997. Default Value is 60000 milliSeconds " DEFVAL { 300 } ::= { isupTimerCfgEntry 10 } isupTmrT20 OBJECT-TYPE SYNTAX INTEGER(4000..60000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T20 timer - group unblocking sent GR-246-CORE, Issue 2, December 1997. Default Value is 4000 milliSeconds " DEFVAL { 15000 } ::= { isupTimerCfgEntry 11 } isupTmrT21 OBJECT-TYPE SYNTAX INTEGER(60..900) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T21 timer - initial group unblocking sent GR-246-CORE, Issue 2, December 1997. Default Value is 60000 milliSeconds " DEFVAL { 30 } ::= { isupTimerCfgEntry 12 } isupTmrT22 OBJECT-TYPE SYNTAX INTEGER(4000..60000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T22 timer - group reset sent GR-246-CORE, Issue 2, December 1997. Default Value is 4000 milliSeconds " DEFVAL { 15000 } ::= { isupTimerCfgEntry 13 } isupTmrT23 OBJECT-TYPE SYNTAX INTEGER(60..900) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T23 timer - initial group reset sent GR-246-CORE, Issue 2, December 1997. Default Value is 60000 milliSeconds " DEFVAL { 300 } ::= { isupTimerCfgEntry 14 } isupTmrT27 OBJECT-TYPE SYNTAX INTEGER(18..24) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T27 timer - waiting for continuity recheck GR-246-CORE, Issue 2, December 1997. Default Value is 200000 milliSeconds " DEFVAL { 18 } ::= { isupTimerCfgEntry 15 } isupTmrT28 OBJECT-TYPE SYNTAX INTEGER(10000..10000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T28 timer - circuit group query sent GR-246-CORE, Issue 2, December 1997. Default Value is 10000 milliSeconds " DEFVAL { 10000 } ::= { isupTimerCfgEntry 16 } isupTmrT31 OBJECT-TYPE SYNTAX INTEGER(360) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T31 timer - call reference frozen period GR-246-CORE, Issue 2, December 1997. Default Value is 360000 milliSeconds " DEFVAL { 360 } ::= { isupTimerCfgEntry 17 } isupTmrT33 OBJECT-TYPE SYNTAX INTEGER(12000..15000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T33 timer - INR sent GR-246-CORE, Issue 2, December 1997. Default Value is 12000 milliSeconds " DEFVAL { 12000 } ::= { isupTimerCfgEntry 18 } isupTmrT34 OBJECT-TYPE SYNTAX INTEGER(10000..15000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T34 timer - currently unknown. Default Value is 10000 milliSeconds " DEFVAL { 10000 } ::= { isupTimerCfgEntry 19 } isupTmrT36 OBJECT-TYPE SYNTAX INTEGER(2000..4000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T36 timer - waiting for continuity after recheck, in bellcore it is T34 GR-246-CORE, Issue 2, December 1997. Default Value is 2000 milliSeconds " DEFVAL { 2000 } ::= { isupTimerCfgEntry 20 } isupTmrTCCR OBJECT-TYPE SYNTAX INTEGER(20000..24000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "tCCR timer - continuity recheck timer GR-246-CORE, Issue 2, December 1997. Default Value is 20000 milliSeconds " DEFVAL { 20000 } ::= { isupTimerCfgEntry 21 } isupTmrTEX OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "TEX timer - Exit to be sent, currently not applicable " DEFVAL { 0 } ::= { isupTimerCfgEntry 22 } isupTmrTCRM OBJECT-TYPE SYNTAX INTEGER(3000..4000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "TCRM timer - circuit reservation message sent. GR-246-CORE, Issue 2, December 1997. Default Value is 3000 milliSeconds " DEFVAL { 3000 } ::= { isupTimerCfgEntry 23 } isupTmrTCRA OBJECT-TYPE SYNTAX INTEGER(0..20000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "TCRA timer - circuit reservation acknowledgement sent. GR-246-CORE, Issue 2, December 1997. Default Value is 20000 milliSeconds " DEFVAL { 0 } ::= { isupTimerCfgEntry 24 } isupTmrTCCRt OBJECT-TYPE SYNTAX INTEGER(0..2000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "TCCRt timer - tCCR timer (o/g side). Default Value is 0 milliSeconds " DEFVAL { 0 } ::= { isupTimerCfgEntry 25 } isupTmrTECt OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "tECT timer - Explicit Call Transfer -wait for loop prvnt rsp. Default Value is 0 milliSeconds " DEFVAL { 0 } ::= { isupTimerCfgEntry 26 } isupTmrTGTCHG OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "Timer tGTCHG - Awaiting charging extended acknowledgement after having sent CHGE " DEFVAL { 0 } ::= { isupTimerCfgEntry 27 } isupTmrTGRES OBJECT-TYPE SYNTAX INTEGER(5000..5000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "TGRS timer - at receipt of circuit group reset message, treat subsequent circuit group reset messages new only on this timer expiration. " DEFVAL { 5000 } ::= { isupTimerCfgEntry 28 } isupTmrTFGR OBJECT-TYPE SYNTAX INTEGER(10000..120000) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "TFGR timer - first group received timer GR-246-CORE, Issue 2, December 1997 " DEFVAL { 0 } ::= { isupTimerCfgEntry 29 } isupTmrTRELRSP OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "Time tRELRSP - Awaiting for release response. Default Value is 0 milliSeconds " DEFVAL { 0 } ::= { isupTimerCfgEntry 30 } isupTmrTFNLRELRS OBJECT-TYPE SYNTAX INTEGER(1..65535) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "Time tFNLRELRSP - Awaiting for final release response. Default Value is 0 milliSeconds " DEFVAL { 0 } ::= { isupTimerCfgEntry 31 } isupTimerRowStatus OBJECT-TYPE SYNTAX ModifyTmrStatus ACCESS read-write STATUS mandatory DESCRIPTION "This is a command to MODIFY a Timer. A 'GET' operation on this object will display the default value [no action]. The possible option for 'SET' operation is: 1)modify " ::= { isupTimerCfgEntry 32 } -- ************************************************* -- Ss7 DPC Route -- ************************************************* ss7RtDpcTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7RtDpcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SS7 Route Dpc Table. The Information about Route(s) in MSSC are provided in this table. This table has one index: ss7RtDPC (Integer). " ::= { ss7Route 1 } ss7RtDpcEntry OBJECT-TYPE SYNTAX Ss7RtDpcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7RtDPC } ::= { ss7RtDpcTable 1 } Ss7RtDpcEntry ::= SEQUENCE { ss7RtDPC INTEGER, ss7RtCmbLinksetId INTEGER, ss7RtLoadShareType Standard, ss7RtRowStatus RowStatus, ss7RtOpStatus OpStatus } ss7RtDPC OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "The Route Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7RtDpcEntry 1 } ss7RtCmbLinksetId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "SS7 Linkset Id which is already configured so far. An incorrect Linkset Id will result a failure at the time of 'CREATION' of the Route table for the specified DPC. " ::= { ss7RtDpcEntry 2 } ss7RtLoadShareType OBJECT-TYPE SYNTAX Standard ACCESS read-write STATUS mandatory DESCRIPTION "Load Share type(ANSI/ITU) " ::= { ss7RtDpcEntry 3 } ss7RtRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this SS7 Route. To Configure this Route, the only option is 'CREATEANDWAIT'. To Delete this Route, the only option is 'DESTROY'. For the 'GET' Operation, the possible options are 1) active 2) notinservice 3" ::= { ss7RtDpcEntry 4 } ss7RtOpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this SS7 Route. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { ss7RtDpcEntry 5 } -- ************************************************* -- ISDN Trunk Timer config table -- ************************************************* isdnTmrCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdnTmrCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ISDN Timer Table. The Information about ISDN Timers in MSSC are provided in this table. User can Modify Timer(s) from this table. This table has one index: isdnTnkId (Integer). " ::= { isdn 1 } isdnTmrCfgEntry OBJECT-TYPE SYNTAX IsdnTmrCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { isdnTnkId } ::= { isdnTmrCfgTable 1 } IsdnTmrCfgEntry ::= SEQUENCE { isdnTnkId INTEGER, isdnTmrT301 INTEGER, isdnTmrT302 INTEGER, isdnTmrT303 INTEGER, isdnTmrT304 INTEGER, isdnTmrT305 INTEGER, isdnTmrT306 INTEGER, isdnTmrT307 INTEGER, isdnTmrT308 INTEGER, isdnTmrT310 INTEGER, isdnTmrT311 INTEGER, isdnTmrT312 INTEGER, isdnTmrT313 INTEGER, isdnTmrT316 INTEGER, isdnTmrT318 INTEGER, isdnTmrT319 INTEGER, isdnTmrT322 INTEGER, isdnTmrT316C INTEGER, isdnTmrT330 INTEGER, isdnTmrT331 INTEGER, isdnTmrT332 INTEGER, isdnTmrTRST INTEGER, isdnTmrTREST INTEGER, isdnTmrTANS INTEGER, isdnTmrT396 INTEGER, isdnTmrT397 INTEGER, isdnTrnkTmrRowStatus TmrRowStatus, isdnTrnkTmrOpStatus OpStatus } isdnTnkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Trunk id. " ::= { isdnTmrCfgEntry 1 } isdnTmrT301 OBJECT-TYPE SYNTAX INTEGER(180..420) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T301 timer - alert received Recommandation Q.931, TABLE 9-1/Q931 " DEFVAL { 180 } ::= { isdnTmrCfgEntry 2 } isdnTmrT302 OBJECT-TYPE SYNTAX INTEGER(0..15000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T302 timer - SETUP ACK sent Receipt of INFO Recommandation Q.931, TABLE 9-1/Q931 " DEFVAL { 0 } ::= { isdnTmrCfgEntry 3 } isdnTmrT303 OBJECT-TYPE SYNTAX INTEGER(1000..4000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T303 timer - setup sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 4000 milliSeconds " DEFVAL { 4000 } ::= { isdnTmrCfgEntry 4 } isdnTmrT304 OBJECT-TYPE SYNTAX INTEGER(0..20000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T304 timer - setup ack received info sent alert Recommandation Q.931, TABLE 9-1/Q931. Default Value is 20000 milliSeconds " DEFVAL { 0 } ::= { isdnTmrCfgEntry 5 } isdnTmrT305 OBJECT-TYPE SYNTAX INTEGER(2000..60000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T305 timer - disc w/ prog ind sent or disc sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 30000 milliSeconds " DEFVAL { 30000 } ::= { isdnTmrCfgEntry 6 } isdnTmrT306 OBJECT-TYPE SYNTAX INTEGER(30..150) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T306 timer - disc without prog ind sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 30000 milliSeconds " DEFVAL { 30 } ::= { isdnTmrCfgEntry 7 } isdnTmrT307 OBJECT-TYPE SYNTAX INTEGER(0..180) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T307 timer - iusp ack sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 180000 milliSeconds " DEFVAL { 0 } ::= { isdnTmrCfgEntry 8 } isdnTmrT308 OBJECT-TYPE SYNTAX INTEGER(2000..10000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T308 timer - release sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 4000 milliSeconds " DEFVAL { 4000 } ::= { isdnTmrCfgEntry 9 } isdnTmrT310 OBJECT-TYPE SYNTAX INTEGER(3000..10000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T310 timer - call proc received Recommandation Q.931, TABLE 9-1/Q931. Default Value is 10000 milliSeconds " DEFVAL { 10000 } ::= { isdnTmrCfgEntry 10 } isdnTmrT311 OBJECT-TYPE SYNTAX INTEGER(0..65535) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "T310 timer - call proc received, not in the network side " ::= { isdnTmrCfgEntry 11 } isdnTmrT312 OBJECT-TYPE SYNTAX INTEGER(0..6000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T312 timer - setup sent on broadcast Recommandation Q.931, TABLE 9-1/Q931. Default Value is 6000 milliSeconds " DEFVAL { 0 } ::= { isdnTmrCfgEntry 12 } isdnTmrT313 OBJECT-TYPE SYNTAX INTEGER(0..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T313 timer - conn sent, not in BellCore network side " DEFVAL { 0 } ::= { isdnTmrCfgEntry 13 } isdnTmrT316 OBJECT-TYPE SYNTAX INTEGER(10..120) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "T316 timer - restart sent interface Recommandation Q.931, TABLE 9-1/Q931. Default Value is 120000 milliSeconds " DEFVAL { 30 } ::= { isdnTmrCfgEntry 14 } isdnTmrT318 OBJECT-TYPE SYNTAX INTEGER(0..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T318 timer - resume sent, not in bellcore network side " DEFVAL { 0 } ::= { isdnTmrCfgEntry 15 } isdnTmrT319 OBJECT-TYPE SYNTAX INTEGER(0..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T319 timer - suspend sent, not in Bellcore network side " DEFVAL { 0 } ::= { isdnTmrCfgEntry 16 } isdnTmrT322 OBJECT-TYPE SYNTAX INTEGER(2000..10000) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T322 timer - stat enq sent Recommandation Q.931, TABLE 9-1/Q931. Default Value is 4000 milliSeconds " DEFVAL { 4000 } ::= { isdnTmrCfgEntry 17 } isdnTmrT316C OBJECT-TYPE SYNTAX INTEGER(30..120) UNITS "sec" ACCESS read-only STATUS mandatory DESCRIPTION "T316c Timer -Restart sent to individual channel " DEFVAL { 30 } ::= { isdnTmrCfgEntry 18 } isdnTmrT330 OBJECT-TYPE SYNTAX INTEGER(0..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T330 Timer - Congestion with Upper " DEFVAL { 0 } ::= { isdnTmrCfgEntry 19 } isdnTmrT331 OBJECT-TYPE SYNTAX INTEGER(0..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T331 Timer - Congestion with lower " DEFVAL { 0 } ::= { isdnTmrCfgEntry 20 } isdnTmrT332 OBJECT-TYPE SYNTAX INTEGER(0..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T332 Timer - Service request sent " DEFVAL { 0 } ::= { isdnTmrCfgEntry 21 } isdnTmrTRST OBJECT-TYPE SYNTAX INTEGER(30..600) UNITS "sec" ACCESS read-only STATUS mandatory DESCRIPTION "TRst Timer - Disconnect indication sent while restarting interface " DEFVAL { 120 } ::= { isdnTmrCfgEntry 22 } isdnTmrTREST OBJECT-TYPE SYNTAX INTEGER(30..600) UNITS "sec" ACCESS read-write STATUS mandatory DESCRIPTION "TREST Timer - Disconnect indication sent while NI2 restarting interface " DEFVAL { 120 } ::= { isdnTmrCfgEntry 23 } isdnTmrTANS OBJECT-TYPE SYNTAX INTEGER(1..65553) UNITS "ms" ACCESS read-only STATUS mandatory DESCRIPTION "TAns Timer - Answer timer " ::= { isdnTmrCfgEntry 24 } isdnTmrT396 OBJECT-TYPE SYNTAX INTEGER(0..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T396 Timer - t303 expired " DEFVAL { 0 } ::= { isdnTmrCfgEntry 25 } isdnTmrT397 OBJECT-TYPE SYNTAX INTEGER(0..65535) UNITS "ms" ACCESS read-write STATUS mandatory DESCRIPTION "T397 Timer - Information sent on permanent signal " DEFVAL { 0 } ::= { isdnTmrCfgEntry 26 } isdnTrnkTmrRowStatus OBJECT-TYPE SYNTAX TmrRowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this Isdn Trunk Timer. To Modify any Timer for this Trunk, the only option is 'MODIFYTIMER'. For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notready 4) modified 5) up 6) do" ::= { isdnTmrCfgEntry 27 } isdnTrnkTmrOpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this Isdn Timer. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { isdnTmrCfgEntry 28 } -- ************************************************* -- ISDN Trunk Config Table -- ************************************************* isdnTrunkCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdnTrunkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ISDN Trunk Table. Information about the ISDN Trunk(s) in MSSC are provided in this table. The index of this table is isdnTrunkId (Integer) " ::= { isdn 2 } isdnTrunkCfgEntry OBJECT-TYPE SYNTAX IsdnTrunkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { isdnTrunkId } ::= { isdnTrunkCfgTable 1 } IsdnTrunkCfgEntry ::= SEQUENCE { isdnTrunkId INTEGER, isdnTrunkName NameString, isdnTrunkGrpId INTEGER, isdnDchnlId INTEGER, isdnTrunkType IsdnType, isdnXconnectId INTEGER, isdnSlotId INTEGER, isdnPortId INTEGER, isdnDirection Direction, isdnPriority IsdnPriority, isdnDurthreshold INTEGER, isdnCntthreshold INTEGER, isdnPhyIntfType IfType, isdnDchnlTimeSlot INTEGER, isdnE1MultiFrame E1MultiFrame, isdnE1CRC4 E1CRC4, isdnE1TransClk TransClkSrc, isdnDS1LineType DS1LineType, isdnDS1LineCoding DS1LineCoding, isdnDS1TransClkSrc TransClkSrc, isdnDS1LBO DS1LBO, isdnDS3LineType DS3LineType, isdnDS3TransClkSrc TransClkSrc, isdnDS3LBO DS3LBO, isdnDS3DS1LineType DS1LineType, isdnDS3DS1TransClkSrc TransClkSrc, isdnTrunkRowStatus RowStatus, isdnTrunkOpStatus IsdnTrnkOpStatus } isdnTrunkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Trunk id. Can be any integer 1-65535. " ::= { isdnTrunkCfgEntry 1 } isdnTrunkName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "Trunk name. Can be any combinaton of alphanumeric characters. Spaces are not allowed. " ::= { isdnTrunkCfgEntry 2 } isdnTrunkGrpId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Trunk Group id to which the trunk belongs. Can be any integer 1-65535. " ::= { isdnTrunkCfgEntry 3 } isdnDchnlId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "D-Channel Id " ::= { isdnTrunkCfgEntry 4 } isdnTrunkType OBJECT-TYPE SYNTAX IsdnType ACCESS read-write STATUS mandatory DESCRIPTION "Trunk Type (nfas/fas). " ::= { isdnTrunkCfgEntry 5 } isdnXconnectId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Xconnect id " ::= { isdnTrunkCfgEntry 6 } isdnSlotId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Slot id " ::= { isdnTrunkCfgEntry 7 } isdnPortId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port id " ::= { isdnTrunkCfgEntry 8 } isdnDirection OBJECT-TYPE SYNTAX Direction ACCESS read-write STATUS mandatory DESCRIPTION "Traffic direction. possible options are 1) in 2) out 3) both " ::= { isdnTrunkCfgEntry 9 } isdnPriority OBJECT-TYPE SYNTAX IsdnPriority ACCESS read-write STATUS mandatory DESCRIPTION "Traffic priority " ::= { isdnTrunkCfgEntry 10 } isdnDurthreshold OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Bad Call Duration Threshold " ::= { isdnTrunkCfgEntry 11 } isdnCntthreshold OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Bad Call Count Threshold " ::= { isdnTrunkCfgEntry 12 } isdnPhyIntfType OBJECT-TYPE SYNTAX IfType ACCESS read-write STATUS mandatory DESCRIPTION "Isdn Physical Interface Type possible options are 1) T1 (interface-t1) 2) T3 (interface-t3) 3) Unchannelized T3 (interface-ut3) 4) OC3 (interface-oc3) 5) Unchannelized T3 with compression (interface-ut3cp) 6) OC3 with compression (interface-oc3cp) " ::= { isdnTrunkCfgEntry 13 } isdnDchnlTimeSlot OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "D-Channel Time slot " ::= { isdnTrunkCfgEntry 14 } isdnE1MultiFrame OBJECT-TYPE SYNTAX E1MultiFrame ACCESS read-write STATUS mandatory DESCRIPTION "E1 multiFrame Type possible options are 1) CAS(1) 2) CCS(2)" ::= { isdnTrunkCfgEntry 15 } isdnE1CRC4 OBJECT-TYPE SYNTAX E1CRC4 ACCESS read-write STATUS mandatory DESCRIPTION "E1 Cyclic Redundancy Code, possible options are 1) enabled(1) 2) disable(2)" ::= { isdnTrunkCfgEntry 16 } isdnE1TransClk OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "E1 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { isdnTrunkCfgEntry 17 } isdnDS1LineType OBJECT-TYPE SYNTAX DS1LineType ACCESS read-write STATUS mandatory DESCRIPTION "DS1 Line Type possible options are 1) esF(1) 2) d4(2)" ::= { isdnTrunkCfgEntry 18 } isdnDS1LineCoding OBJECT-TYPE SYNTAX DS1LineCoding ACCESS read-write STATUS mandatory DESCRIPTION "DS1 Line Coding, possible options are 1) b8zs(1) 2) ami(2)" ::= { isdnTrunkCfgEntry 19 } isdnDS1TransClkSrc OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "DS1 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { isdnTrunkCfgEntry 20 } isdnDS1LBO OBJECT-TYPE SYNTAX DS1LBO ACCESS read-write STATUS mandatory DESCRIPTION "DS1 Line Build Out, possible options are 1) upTo133Feet(1) 2) upTo266Feet(2) 3) upTo399Feet(3) 4) upTo533Feet(4) 5) upTo655Feet(5) 6) negative7_5Db(6) 7) negative15Db(7) 8) negative22_5Db(8)" ::= { isdnTrunkCfgEntry 21 } isdnDS3LineType OBJECT-TYPE SYNTAX DS3LineType ACCESS read-write STATUS mandatory DESCRIPTION "DS3 Line Type possible options are 1) cbitParity(1) 2) clearChannel(2)" ::= { isdnTrunkCfgEntry 22 } isdnDS3TransClkSrc OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "DS3 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { isdnTrunkCfgEntry 23 } isdnDS3LBO OBJECT-TYPE SYNTAX DS3LBO ACCESS read-write STATUS mandatory DESCRIPTION "DS3 Line Build Out possible options are 1) short(1) 2) long(2)" ::= { isdnTrunkCfgEntry 24 } isdnDS3DS1LineType OBJECT-TYPE SYNTAX DS1LineType ACCESS read-write STATUS mandatory DESCRIPTION "DS3DS1 Line Type possible options are 1) esF(1) 2) d4(2)" ::= { isdnTrunkCfgEntry 25 } isdnDS3DS1TransClkSrc OBJECT-TYPE SYNTAX TransClkSrc ACCESS read-write STATUS mandatory DESCRIPTION "DS3DS1 Transmit Clock Source, possible options are 1) loopTiming(1) 2) localTiming(2)" ::= { isdnTrunkCfgEntry 26 } isdnTrunkRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this ISDN TRUNK. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) n" ::= { isdnTrunkCfgEntry 27 } isdnTrunkOpStatus OBJECT-TYPE SYNTAX IsdnTrnkOpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this ISDN Trunk. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) disable " ::= { isdnTrunkCfgEntry 28 } -- ************************************************* -- ISDN Channel status Table -- ************************************************* isdnChnlStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdnChnlStatusCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ISDN Channel Status Table. Information about the DS0 Channel(s) Status in MSSC are provided in this table. The index of this table is isdnStatusTrunkId (Integer) " ::= { isdn 3 } isdnChnlStatusCfgEntry OBJECT-TYPE SYNTAX IsdnChnlStatusCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { isdnStatusTrunkId, isdnStatusChnlId } ::= { isdnChnlStatusTable 1 } IsdnChnlStatusCfgEntry ::= SEQUENCE { isdnStatusTrunkId INTEGER, isdnStatusChnlId INTEGER, isdnStatusChnlState TrunkState, isdnStatusChnlAllocMeth INTEGER, isdnStatusChnlSuConnId INTEGER } isdnStatusTrunkId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { isdnChnlStatusCfgEntry 1 } isdnStatusChnlId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Channel id. " ::= { isdnChnlStatusCfgEntry 2 } isdnStatusChnlState OBJECT-TYPE SYNTAX TrunkState ACCESS read-only STATUS mandatory DESCRIPTION "Isdn Channel String. " ::= { isdnChnlStatusCfgEntry 3 } isdnStatusChnlAllocMeth OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Isdn Channel AllocMeth. " ::= { isdnChnlStatusCfgEntry 4 } isdnStatusChnlSuConnId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Isdn Channel SuConnId. " ::= { isdnChnlStatusCfgEntry 5 } -- ************************************************* -- Isdn mangment command Group -- ************************************************* isdnMgmntGroup OBJECT IDENTIFIER ::= { isdn 4 } -- ************************************************* -- Isdn Trunk management table -- ************************************************* isdnTrnkMgmntTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdnTrnkMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ISDN Trunk Management Table. The Management Commands for ISDN Trunk(s) in MSSC are provided in this table. This table has the index isdnTrnkMgmntId (Integer). " ::= { isdnMgmntGroup 1 } isdnTrnkMgmntEntry OBJECT-TYPE SYNTAX IsdnTrnkMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { isdnTrnkMgmntId } ::= { isdnTrnkMgmntTable 1 } IsdnTrnkMgmntEntry ::= SEQUENCE { isdnTrnkMgmntId INTEGER, isdnTrnkMgmntCmd IsdnTrnkMgtOperation } isdnTrnkMgmntId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk id. " ::= { isdnTrnkMgmntEntry 1 } isdnTrnkMgmntCmd OBJECT-TYPE SYNTAX IsdnTrnkMgtOperation ACCESS read-write STATUS mandatory DESCRIPTION "Management Command for Enabling/Disabling the specified trunk group. This command will make all the channels in this trunk available The possible options are : 1) Enable 2) Disable [default] " ::= { isdnTrnkMgmntEntry 2 } -- ************************************************* -- Isdn Channel management Table -- ************************************************* isdnChnlMgmntTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdnChnlMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "ISDN Trunk Channel Management Table. The Management Commands for ISDN Trunk(s) in MSSC are provided in this table. This table has the index isdnTrunkMgmntId (Integer). " ::= { isdnMgmntGroup 2 } isdnChnlMgmntEntry OBJECT-TYPE SYNTAX IsdnChnlMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { isdnTrunkMgmntId, isdnChnlMgmntId } ::= { isdnChnlMgmntTable 1 } IsdnChnlMgmntEntry ::= SEQUENCE { isdnTrunkMgmntId INTEGER, isdnChnlMgmntId INTEGER, isdnChnlMgmntCmd IsdnChnlMgtOperation } isdnTrunkMgmntId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk id. " ::= { isdnChnlMgmntEntry 1 } isdnChnlMgmntId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Channel id. " ::= { isdnChnlMgmntEntry 2 } isdnChnlMgmntCmd OBJECT-TYPE SYNTAX IsdnChnlMgtOperation ACCESS read-write STATUS mandatory DESCRIPTION "Management Command for Enabling/Disabling the specified Channel in the specified trunk. The possible options are : 1) Enable 2) Disable [default] " ::= { isdnChnlMgmntEntry 3 } -- ************************************************* -- MFD Managment table -- ************************************************* mfdMgmntTable OBJECT-TYPE SYNTAX SEQUENCE OF MfdMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Modem Fault Management Table. The Management Commands for Modem(s) in MSSC are provided in this table. This table has the index isdnTnkMgmntId (Integer). " ::= { isdnMgmntGroup 3 } mfdMgmntEntry OBJECT-TYPE SYNTAX MfdMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { isdnTnkMgmntId } ::= { mfdMgmntTable 1 } MfdMgmntEntry ::= SEQUENCE { isdnTnkMgmntId INTEGER, isdnDurThreshold INTEGER, isdnCntThreshold INTEGER, mfdMgmntCmd EnableOperation } isdnTnkMgmntId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Isdn Trunk id. " ::= { mfdMgmntEntry 1 } isdnDurThreshold OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Bad Call Duration Threshold. A value 0 means disable. If mfd is enabled the normal value for this field would be 3 " ::= { mfdMgmntEntry 2 } isdnCntThreshold OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Bad Call Count Threshold A value 0 means disable. If mfd is enabled the normal value for this field would be 3 " ::= { mfdMgmntEntry 3 } mfdMgmntCmd OBJECT-TYPE SYNTAX EnableOperation ACCESS read-write STATUS mandatory DESCRIPTION "Management Command for Enabling/Disabling 'MODEM FAULT DETECTION' feature in MSSC. The possible options are : 1) Enable 2) Disable [default] " ::= { mfdMgmntEntry 4 } -- ************************************************* -- Isdn Physical Interface Configuration Table -- ************************************************* -- ************************************************* -- Route Config Table -- ************************************************* routeTable OBJECT-TYPE SYNTAX SEQUENCE OF RouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Route Table. Information about the Route(s) in MSSC are provided in this table. The index of this table is routeId (Integer) " ::= { rt 1 } routeEntry OBJECT-TYPE SYNTAX RouteEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { routeId } ::= { routeTable 1 } RouteEntry ::= SEQUENCE { routeId INTEGER, routeAddrType AddrType, routeAdrId AddrIdentifier, routeAddr AddrString, routeNumPlan NumPlan, routeNumOfDigit INTEGER, routeRouteName NameString, routeRouteType RouteType, routeRowStatus RowStatus, routeOpStatus OpStatus } routeId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Route Group id. Can be any integer 1-65535. " ::= { routeEntry 1 } routeAddrType OBJECT-TYPE SYNTAX AddrType ACCESS read-write STATUS mandatory DESCRIPTION "Call Control routing type The possible option are: 1) Call party number 2) Transit Network Selection " ::= { routeEntry 2 } routeAdrId OBJECT-TYPE SYNTAX AddrIdentifier ACCESS read-write STATUS mandatory DESCRIPTION "Call Control route request nature of address. The possible options are: 1) National number 2) International number 3) Unknown " ::= { routeEntry 3 } routeAddr OBJECT-TYPE SYNTAX AddrString ACCESS read-write STATUS mandatory DESCRIPTION "Call Control routing number " ::= { routeEntry 4 } routeNumPlan OBJECT-TYPE SYNTAX NumPlan ACCESS read-write STATUS mandatory DESCRIPTION "Call control route request numbering plan. The possible options are: 1) Number not present(nonumber) 2) ISDN numbering Plan(isdnnumplan) 3) Telephony numbering plan(telephonynumplan) 4) Private Numbering Plan(privatenumplan) " ::= { routeEntry 5 } routeNumOfDigit OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Number of Digit in the route. " ::= { routeEntry 6 } routeRouteName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "Route Name. Can be any combination of alphanumeric characters. Spaces are not allowed. " ::= { routeEntry 7 } routeRouteType OBJECT-TYPE SYNTAX RouteType ACCESS read-write STATUS mandatory DESCRIPTION "Route type: SS7/ISDN " ::= { routeEntry 8 } routeRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this ROUTE. To Configure this Route, the only option is 'CREATEANDWAIT' To Delete this Route, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) notr" ::= { routeEntry 9 } routeOpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this Route. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { routeEntry 10 } -- ************************************************* -- CC Route ISDN Configuration Table -- ************************************************* rtEntryIsdnCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF RtEntryIsdnCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "RtEntry Isdn Table. Information about the RtEntry(s) in MSSC are provided in this table.The Table has two indices: rtEntryIsdnGrpId and rtEntryIsdntrunkId (both Integer). " ::= { rt 2 } rtEntryIsdnCfgEntry OBJECT-TYPE SYNTAX RtEntryIsdnCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { rtEntryIsdnGrpId, rtEntryIsdntrunkId } ::= { rtEntryIsdnCfgTable 1 } RtEntryIsdnCfgEntry ::= SEQUENCE { rtEntryIsdnGrpId INTEGER, rtEntryIsdntrunkId INTEGER, rtEntryIsdnRouteName NameString, rtEntryIsdnRowStatus RowStatus, rtEntryIsdnOpStatus OpStatus } rtEntryIsdnGrpId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Route ISDN group id. Can be any integer 1-65535. " ::= { rtEntryIsdnCfgEntry 1 } rtEntryIsdntrunkId OBJECT-TYPE SYNTAX INTEGER(1..256) ACCESS read-write STATUS mandatory DESCRIPTION "Route ISDN Trunk id. Can be any integer 1-256. " ::= { rtEntryIsdnCfgEntry 2 } rtEntryIsdnRouteName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "Route ISDN group name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters. " ::= { rtEntryIsdnCfgEntry 3 } rtEntryIsdnRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this ISDN ROUTE Entry. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice" ::= { rtEntryIsdnCfgEntry 4 } rtEntryIsdnOpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this ISDN Route. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { rtEntryIsdnCfgEntry 5 } -- ************************************************* -- CC RTEntry SS7 Configuration Table -- ************************************************* rtEntrySs7CfgTable OBJECT-TYPE SYNTAX SEQUENCE OF RtEntrySs7CfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "RtEntry SS7 Table. Information about the RtEntry(s) in MSSC are provided in this table.The Table has two indices: rtEntrySs7GrpId and rtEntrySs7CmbLinksetId (both Integer). " ::= { rt 3 } rtEntrySs7CfgEntry OBJECT-TYPE SYNTAX RtEntrySs7CfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { rtEntrySs7GrpId, rtEntrySs7CmbLinksetId } ::= { rtEntrySs7CfgTable 1 } RtEntrySs7CfgEntry ::= SEQUENCE { rtEntrySs7GrpId INTEGER, rtEntrySs7CmbLinksetId INTEGER, rtEntrySs7RouteName NameString, rtEntrySs7Dpc INTEGER, rtEntrySs7Mode Standard, rtEntrySs7RowStatus RowStatus, rtEntrySs7OpStatus OpStatus } rtEntrySs7GrpId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Route SS7 group id. Can be any integer 1-65535. " ::= { rtEntrySs7CfgEntry 1 } rtEntrySs7CmbLinksetId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "SS7 Linkset Id which is already configured so far. An incorrect Linkset Id will result a failure at the time of 'CREATION' of the RtEntry ie, addition of the Destination Point Code into the specified Route will fail. " ::= { rtEntrySs7CfgEntry 2 } rtEntrySs7RouteName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "Route SS7 group name. Can be any combination of alphanumeric characters Spaces are not allowed and cannot exceed 15 characters. " ::= { rtEntrySs7CfgEntry 3 } rtEntrySs7Dpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Route SS7 Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { rtEntrySs7CfgEntry 4 } rtEntrySs7Mode OBJECT-TYPE SYNTAX Standard ACCESS read-write STATUS mandatory DESCRIPTION "Route SS7 Type(ANSI/ITU) " ::= { rtEntrySs7CfgEntry 5 } rtEntrySs7RowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this SS7 Route Entry. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice " ::= { rtEntrySs7CfgEntry 6 } rtEntrySs7OpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this SS7 Route. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { rtEntrySs7CfgEntry 7 } -- ************************************************* -- Route Management table -- ************************************************* routeMgmntCmdGroup OBJECT IDENTIFIER ::= { rt 4 } -- ************************************************* -- Rout Management Table -- ************************************************* digitStripMgmntTable OBJECT-TYPE SYNTAX SEQUENCE OF DigitStripMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Route Management Command Table. Commands for enabling or disabling digit stripping in MSSC's routing feature are applied here. The index for this table is rtName(String). " ::= { routeMgmntCmdGroup 1 } digitStripMgmntEntry OBJECT-TYPE SYNTAX DigitStripMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { rtName } ::= { digitStripMgmntTable 1 } DigitStripMgmntEntry ::= SEQUENCE { rtName NameString, rtAddrType AddrIdentifier, rtNumOfDigit INTEGER, rtMgmntCmd EnableOperation } rtName OBJECT-TYPE SYNTAX NameString ACCESS read-only STATUS mandatory DESCRIPTION "Route Name. Can be any combination of alphanumeric characters. Spaces are not allowed. " ::= { digitStripMgmntEntry 1 } rtAddrType OBJECT-TYPE SYNTAX AddrIdentifier ACCESS read-write STATUS mandatory DESCRIPTION "Call Control route request nature of address. The possible options are: 1) National number 2) International number 3) Unknown " ::= { digitStripMgmntEntry 2 } rtNumOfDigit OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Number of Digit in the route. " ::= { digitStripMgmntEntry 3 } rtMgmntCmd OBJECT-TYPE SYNTAX EnableOperation ACCESS read-write STATUS mandatory DESCRIPTION "Management Command for Enabling/Disabling Digit Strip for MSSC's Routing Feature. The possible options are : 1) Enable 2) Disable [default] " ::= { digitStripMgmntEntry 4 } -- ************************************************* -- Route Management Table ( ILB) -- ************************************************* isdnLoadBalanceMgmntTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdnLoadBalanceMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Isdn Channel Load Balance Command Table. Turning this feature on will result in distributing all the incoming calls evenly in all the trunks for the specified route number. The index for this table is rteName(String). " ::= { routeMgmntCmdGroup 2 } isdnLoadBalanceMgmntEntry OBJECT-TYPE SYNTAX IsdnLoadBalanceMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { rteName } ::= { isdnLoadBalanceMgmntTable 1 } IsdnLoadBalanceMgmntEntry ::= SEQUENCE { rteName NameString, ilbMgmntCmd EnableOperation } rteName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "Route Name. Can be any combination of alphanumeric characters. Spaces are not allowed. " ::= { isdnLoadBalanceMgmntEntry 1 } ilbMgmntCmd OBJECT-TYPE SYNTAX EnableOperation ACCESS read-write STATUS mandatory DESCRIPTION "Management Command for Enabling/Disabling the feature 'ISDN Channel LOAD BALANCE'. When this feature is turned on all the incoming calls are distributed evenly in all the trunks for the specified routing numbers. The possible options are : 1) Enable " ::= { isdnLoadBalanceMgmntEntry 2 } -- ************************************************* -- Enable Group -- ************************************************* enableSwitch OBJECT-TYPE SYNTAX EnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "This is POST-CONFIGURATION command to ENABLE the switch. The 'GET' operation will result in the default value (no) being returned. The possible options are: 1) yes 2) no (Default) " ::= { enableGroup 1 } enableSS7Route OBJECT-TYPE SYNTAX EnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "This is POST-CONFIGURATION command to ENABLE the SS7 Route. The 'GET' operation will result in the default value (no) being returned. The possible options are: 1) yes 2) no (Default) " ::= { enableGroup 2 } enableSS7Ckt OBJECT-TYPE SYNTAX EnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "This is POST-CONFIGURATION command to ENABLE the SS7 Circuit. This Command can only be applied to Enable the SS7 Circuit and COMMIT all the SS7 Circuit Configuration. The 'GET' operation will result in the default value (no) being returned. The possib" ::= { enableGroup 3 } enableIsdntrunk OBJECT-TYPE SYNTAX EnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "This is POST-CONFIGURATION command to ENABLE the ISDN Trunk. This Command can only be applied to Enable the ISDN Trunk. The 'GET' operation will result in the default value (no) being returned. The possible options are: 1) yes 2) no (Default) " ::= { enableGroup 4 } enableXconnect OBJECT-TYPE SYNTAX EnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "This is POST-CONFIGURATION command to ENABLE the Xconnect. The 'GET' operation will result in the default value (no) being returned. The possible options are: 1) yes 2) no (Default) " ::= { enableGroup 5 } enableRoute OBJECT-TYPE SYNTAX EnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "This is POST-CONFIGURATION command to ENABLE the ROUTE and COMMIT all the configuration set for MTP2. This Command can only be applied to Enable the XConnect. The 'GET' operation will result in the default value (no) being returned. The possible optio" ::= { enableGroup 6 } -- ************************************************* -- meas file group -- ************************************************* measFileInfo OBJECT IDENTIFIER ::= { measFile 1 } measFileConfig OBJECT IDENTIFIER ::= { measFile 2 } measFileEnableGrp OBJECT IDENTIFIER ::= { measFile 3 } -- ************************************************* -- MeasureMent File Info -- ************************************************* measFileAcknowledge OBJECT-TYPE SYNTAX DisplayString(SIZE(1..255)) ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledgement of the receiving of the specified Measurement file " ::= { measFileInfo 1 } measFileCfgMeasInterval OBJECT-TYPE SYNTAX INTEGER(0..60) ACCESS read-write STATUS mandatory DESCRIPTION "Switch Config Measure Interval. The duration of the collection window (frequency of persisting collected measurements). Default: 15 minutes. Valid Values: 15, 30, 60 minutes. 0 for Disable. " ::= { measFileConfig 1 } measFileCfgUsagescanInterval OBJECT-TYPE SYNTAX INTEGER(5..300) ACCESS read-write STATUS mandatory DESCRIPTION "Switch Config Usage Scan Interval. The interval between scanning the trunk for usage counts. Default: 15 seconds Valid Values: 5 through 300 seconds. " ::= { measFileConfig 2 } measFileCfgPurgeDay OBJECT-TYPE SYNTAX INTEGER(0..30) ACCESS read-write STATUS mandatory DESCRIPTION "File Config Purge Day. After The specified no of days the file in secondary directory are purged if Measurement File Auto Purge Flag is on. " ::= { measFileConfig 3 } measFileCfgPurgeFlag OBJECT-TYPE SYNTAX MeasPurgeFlag ACCESS read-write STATUS mandatory DESCRIPTION "File Config Flag. This is an auto purge flag. " ::= { measFileConfig 4 } measFileCfgPrimaryDir OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Measurement File Primary Dir. Measurement file is written in this directory " ::= { measFileConfig 5 } measFileCfgSecondaryDir OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Measurement File Secondary Dir. Measurement file is moved to this directory from Primary Directory after receving the acknowledgement. " ::= { measFileConfig 6 } -- ************************************************* -- Measurement Enabl Group -- ************************************************* measFileEnablePRITraffic OBJECT-TYPE SYNTAX MeasEnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "Measurement File PRI Traffic Enable Group. A mechanism for the user to enable collecting of PRI Traffic measurement data. " ::= { measFileEnableGrp 1 } measFileEnableISUPTraffic OBJECT-TYPE SYNTAX MeasEnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "Measurement File ISUP Traffic Enable Group. A mechanism for the user to enable collecting of ISUP Traffic measurement data. " ::= { measFileEnableGrp 2 } measFileEnablePRIIneffectiveCall OBJECT-TYPE SYNTAX MeasEnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "Measurement File Enable PRI Ineffective Call Group. A mechanism for the user to enable collecting of PRI Ineffective Call Group measurement data. " ::= { measFileEnableGrp 3 } measFileEnableISUPIneffectiveCall OBJECT-TYPE SYNTAX MeasEnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "Measurement File Enable PRI Ineffective Call Group. A mechanism for the user to enable collecting of ISUP Ineffective Call Group Traffic measurement data. " ::= { measFileEnableGrp 4 } measFileEnableTrunkGrp OBJECT-TYPE SYNTAX MeasEnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "Measurement File Enable Trunk Group. A mechanism for the user to enable collecting of Trunk Group Traffic measurement data. " ::= { measFileEnableGrp 5 } measFileEnableSS7LinkTraffic OBJECT-TYPE SYNTAX MeasEnableStatus ACCESS read-write STATUS mandatory DESCRIPTION "Measurement File Enable SS7 Link Traffic Group. A mechanism for the user to enable collecting of SS7 Link Traffic measurement data. " ::= { measFileEnableGrp 6 } -- ************************************************* -- Switch Group of Switch Measurement -- ************************************************* measSwitchIsupGrp OBJECT IDENTIFIER ::= { measSwitch 1 } measSwitchIsupFailCallGrp OBJECT IDENTIFIER ::= { measSwitch 2 } measSwitchPriGrp OBJECT IDENTIFIER ::= { measSwitch 3 } measSwitchPriFailCallGrp OBJECT IDENTIFIER ::= { measSwitch 4 } -- ************************************************* -- Trunk Grp Traffic Table of Switch management -- ************************************************* measTrnkGrpTrafficTable OBJECT-TYPE SYNTAX SEQUENCE OF MeasTrnkGrpTrafficEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Measurement for Trunk Group traffic Table. Information about Trunk Group traffic measurement are provoded in this table. The index for this table is measTrnkGrpName(String). " ::= { measTrnkGrp 1 } measTrnkGrpTrafficEntry OBJECT-TYPE SYNTAX MeasTrnkGrpTrafficEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { measTrnkGrpName } ::= { measTrnkGrpTrafficTable 1 } MeasTrnkGrpTrafficEntry ::= SEQUENCE { measTrnkGrpName DisplayString, measTrnkGrpDataSuspect INTEGER, measTrnkGrpincomingUsage INTEGER, measTrnkGrpoutgoingUsage INTEGER, measTrnkGrpISCicsChnls INTEGER, measTrnkGrpOOSCicsChnls INTEGER, measTrnkGrptotalUsage INTEGER, measTrnkGrpmaintainanceUsage INTEGER } measTrnkGrpName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Group Name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters. " ::= { measTrnkGrpTrafficEntry 1 } measTrnkGrpDataSuspect OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Group Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to some condition that occurred during the collection interval. " ::= { measTrnkGrpTrafficEntry 2 } measTrnkGrpincomingUsage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Group Incoming Usage. The sum of the counts of the number of incoming trunks in the use. " ::= { measTrnkGrpTrafficEntry 3 } measTrnkGrpoutgoingUsage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Group Outgoing Usage. The sum of the counts of the number of outgoing trunks in the use. " ::= { measTrnkGrpTrafficEntry 4 } measTrnkGrpISCicsChnls OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Group Inservice Cic/Channels. The sum of the counts of the number of Inservice circuits in case SS7 TrunkGroup or Inservice Channels in case of ISDN TRunkGroup. " ::= { measTrnkGrpTrafficEntry 5 } measTrnkGrpOOSCicsChnls OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Group OutOfservice Cic/Channels. The sum of the counts of the number of OutOfservice circuits in case SS7 TrunkGroup or OufOfservice Channels in case of ISDN TRunkGroup. " ::= { measTrnkGrpTrafficEntry 6 } measTrnkGrptotalUsage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Group Total Usage. The sum of number of trunk in use by both incoming and outgoing traffic. " ::= { measTrnkGrpTrafficEntry 7 } measTrnkGrpmaintainanceUsage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Trunk Group Maintenance Usage. The sum of number of trunk in use for any reason other than traffic. " ::= { measTrnkGrpTrafficEntry 8 } -- ************************************************* -- SS7 Link traffic table of Switch measurement -- ************************************************* measLinkTrafficTable OBJECT-TYPE SYNTAX SEQUENCE OF MeasLinkTrafficEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Switch Measurement per SS7 Link traffic Table. Information about traffic measurement per SS7 Link are provoded in this table. The index for this table is measLinkName(String). " ::= { measLnk 1 } measLinkTrafficEntry OBJECT-TYPE SYNTAX MeasLinkTrafficEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { measLinkName } ::= { measLinkTrafficTable 1 } MeasLinkTrafficEntry ::= SEQUENCE { measLinkName NameString, measLinkDataSuspect INTEGER, measLinkUnavailableDuration INTEGER, measLinkInServiceDuration INTEGER, measLinkMSUsRetransmitted INTEGER, measLinkOctetsReceived INTEGER, measLinkOctectsTransmitted INTEGER, measLinkLostMSUsBufferOverflow INTEGER, measLinkMSUsDiscarded INTEGER } measLinkName OBJECT-TYPE SYNTAX NameString ACCESS read-only STATUS mandatory DESCRIPTION "SS7 Link name " ::= { measLinkTrafficEntry 1 } measLinkDataSuspect OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to some condition that occurred during the collection interval. " ::= { measLinkTrafficEntry 2 } measLinkUnavailableDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link Unavailable Duration. The cumulative time (in sconds) that the link was unavailable during the associated time interval (CS) " ::= { measLinkTrafficEntry 3 } measLinkInServiceDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link In Service Duration. The cumulative time (in seconds) during which the link was in the in-service state. A link is said to be in- service when it is capable of transmitting MSUs. This measurement includes periods when no MSUs are available for tra" ::= { measLinkTrafficEntry 4 } measLinkMSUsRetransmitted OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link MSUs Retransmitted. The number of MSUs retransmitted via a particular link during the associated time period (CS) " ::= { measLinkTrafficEntry 5 } measLinkOctetsReceived OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link Octers Received. The number of SIF and SIO octets received on the associate incoming link (CS) " ::= { measLinkTrafficEntry 6 } measLinkOctectsTransmitted OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link Octets Transmitted. The number of SIF and SIO octets transmitted (including those retransmitted) on the associated incoming link (CS) " ::= { measLinkTrafficEntry 7 } measLinkLostMSUsBufferOverflow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link Lost MSUs Buffer Overflow. The number of MSUs lost because of transmission buffer overflow (CS) " ::= { measLinkTrafficEntry 8 } measLinkMSUsDiscarded OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Link MSUs Discarded. This measurement is a count of number of MSUs discarded. " ::= { measLinkTrafficEntry 9 } -- ************************************************* -- Meas Switch ISUP group -- ************************************************* measSwitchIsupDataSuspect OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to a some condition that occurred during the collection interval " ::= { measSwitchIsupGrp 1 } measSwitchIsupIncomingAnsiTrunkCallAttempts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Incoming Ansi Trunk Call Attempts. The number of incoming ISUP-ANSI trunk call requests. " ::= { measSwitchIsupGrp 2 } measSwitchIsupIncomingAnsiTrunkCallAnswered OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Incoming Ansi Trunk Call Answered. The number of incoming ISUP-ANSI trunk calls answered. " ::= { measSwitchIsupGrp 3 } measSwitchIsupOutgoingAnsiTrunkCallAttempts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Outgoing Ansi Trunk Call Attempts. The number of outgoing ISUP-ANSi trunk call requests. " ::= { measSwitchIsupGrp 4 } measSwitchIsupOutgoingAnsiTrunkCallAnswered OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Outgoing Ansi Trunk Call Answered. The number of outgoing ISUP-ANSI trunk calls answered. " ::= { measSwitchIsupGrp 5 } measSwitchIsupIncomingItutTrunkCallAttempts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Incoming Itut Trunk Call Attempts. The number of incoming ISUP-ITUT trunk call requests. " ::= { measSwitchIsupGrp 6 } measSwitchIsupIncomingItutTrunkCallAnswered OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Incoming Itut Trunk Call Answered. The number of incoming ISUP-ITUT trunk calls answered. " ::= { measSwitchIsupGrp 7 } measSwitchIsupOutgoingItutTrunkCallAttempts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Outgoing Itut Trunk Call Attempts. The number of outgoing ISUP-ITUT trunk call requests. " ::= { measSwitchIsupGrp 8 } measSwitchIsupOutgoingItutTrunkCallAnswered OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Outgoing Itut Trunk Call Answered. The number of outgoing ISUP-ITUT trunk calls answered. " ::= { measSwitchIsupGrp 9 } -- ************************************************* -- Meas Switch ISUP fail Call Group -- ************************************************* measSwitchIsupFailCallDataSuspect OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Fail Call Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to a some condition that occurred during the collection inte" ::= { measSwitchIsupFailCallGrp 1 } measSwitchIsupFailCallAnsiMatchingLoss OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Fail Call Ansi Matching Loss. The number of calls ISUP-ANSI trunk calls that fail to find a linked cross-connect within XCMs on any stage of the call. " ::= { measSwitchIsupFailCallGrp 2 } measSwitchIsupFailCallAnsiNoCircuit OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Fail Call Ansi No Circuit. The number of ISUP-ANSI calls that cannot forwarded on a trunk because: * No idle PRI trunks available * No cross-connect available between XCMs. " ::= { measSwitchIsupFailCallGrp 3 } measSwitchIsupFailCallAnsiCalledPartyLineBusy OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Fail Call Ansi Called Party Line Busy. The number of ISUP-ANSI calls that result in a called party busy indication returned to the caller. " ::= { measSwitchIsupFailCallGrp 4 } measSwitchIsupFailCallAnsiIneffectiveMachineAttempts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Fail Call Ansi Ineffective Machine Attempts. The number of ISUP-ANSI call ineffective machine attempts that have not been associated with any of the following: * Matching loss * No circuit * Called party line busy. " ::= { measSwitchIsupFailCallGrp 5 } measSwitchIsupFailCallItutMatchingLoss OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Fail Call Itut Matching Loss. The number of calls ISUP-ITUT trunk calls that fail to find a linked cross-connect within XCMs on any stage of the call. " ::= { measSwitchIsupFailCallGrp 6 } measSwitchIsupFailCallItutNoCircuit OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Fail Call Itut No Circuit. The number of ISUP-ITUT calls that cannot be forwarded on a trunk because: * No idle PRI trunks available * No cross-connect available between XCMs. " ::= { measSwitchIsupFailCallGrp 7 } measSwitchIsupFailCallItutCalledPartyLineBusy OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Fail Call Itut Called Party Line Busy. The number of ISUP-ITUT calls that result in a called party busy indication returned to the caller. " ::= { measSwitchIsupFailCallGrp 8 } measSwitchIsupFailCallItutIneffectiveMachineAttempts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Isup Fail Call Itut Ineffective Machine Attempts. The number of ISUP-ITUT call ineffective machine attempts that have not been associated with any of the following: * Matching loss * No circuit * Called party line busy. " ::= { measSwitchIsupFailCallGrp 9 } -- ************************************************* -- meas switch ISDN PRI group -- ************************************************* measSwitchPriDataSuspect OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch Primary Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to a some condition that occurred during the collection interval. " ::= { measSwitchPriGrp 1 } measSwitchPriIncomingIsdnPRICallAttempts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch PRI Incoming ISDN PRI Call Attempts. The number of Incoming ISDN trunk call requests. " ::= { measSwitchPriGrp 2 } measSwitchPriIncomingIsdnPRICallAnswered OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch PRI Incoming ISDN PRI Call Answered. The number of Incoming ISDN trunk calls answered. " ::= { measSwitchPriGrp 3 } -- ************************************************* -- meas Switch ISDN PRI group -- ************************************************* measSwitchPriFailCallDataSuspect OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch ISDN PRI Fail Call Data Suspect. Boolean value indicating if the measurement data set is suspect. Suspect data is that which may or may not be accurate and cannot be verified accurate due to a some condition that occurred during the collection " ::= { measSwitchPriFailCallGrp 1 } measSwitchPriFailCallMatchingLoss OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch ISDN PRI Fail Call Matching Loss. The number of calls PRI trunk calls that fail to find a linked cross-connect within XCM on any stage of the call. " ::= { measSwitchPriFailCallGrp 2 } measSwitchPriFailCallNoCircuit OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch ISDN PRI Fail Call No Circuit. The number of PRI calls that cannot be forwarded on a trunk because: * No idle PRI trunks available * No cross-connect available between XCMs. " ::= { measSwitchPriFailCallGrp 3 } measSwitchPriFailCallCalledPartyLineBusy OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch ISDN PRI Fail Call Called Party Line Busy. The number of PRI calls that result in a called party busy indication returned to the caller. " ::= { measSwitchPriFailCallGrp 4 } measSwitchPriFailCallIneffectiveMachineAttempts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Switch ISDN PRI Fail Call Ineffective Machine Attempts. The number of PRI call ineffective machine attempts that have not been associated with any of the following: * Matching loss * No circuit * Called party line busy. " ::= { measSwitchPriFailCallGrp 5 } -- ************************************************* -- Xconnect Config Table -- ************************************************* xconnectCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF XconnectCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "XConnext Table. Information about XConnect(s) in MSSC are provided in this table. The index for this table is xconnectId(Integer). " ::= { xconnect 1 } xconnectCfgEntry OBJECT-TYPE SYNTAX XconnectCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { xconnectId } ::= { xconnectCfgTable 1 } XconnectCfgEntry ::= SEQUENCE { xconnectId INTEGER, xconnectName NameString, xconnectIPAddr IpAddress, xconnectTCPPort INTEGER, xconnectRowStatus RowStatus, xconnectOpStatus OpStatus } xconnectId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Xconnect id. Can be any integer 1-65535. " ::= { xconnectCfgEntry 1 } xconnectName OBJECT-TYPE SYNTAX NameString ACCESS read-write STATUS mandatory DESCRIPTION "Xconnect name. Can be any combination of alphanumeric characters. Spaces are not allowed and cannot exceed 15 characters. " ::= { xconnectCfgEntry 2 } xconnectIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Xconnect IP address. Submit in xxx.xxx.xxx.xxx format. " ::= { xconnectCfgEntry 3 } xconnectTCPPort OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Xconnect TCP port. Can be any integer 1-65535. " ::= { xconnectCfgEntry 4 } xconnectRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this XConnect. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) not" ::= { xconnectCfgEntry 5 } xconnectOpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this XConnect. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { xconnectCfgEntry 6 } -- ************************************************* -- Xlink Config Table -- ************************************************* xlinkCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF XlinkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "XLink Table. Information about XLink(s) in MSSC are provided in this table.This table has six indices: xconnectIdEndA, slotIdEndA, portIdEndA,xconnectIdEndB, xconnectIdEndB,slotIdEndB,portIdEndB (all Integers) " ::= { xconnect 2 } xlinkCfgEntry OBJECT-TYPE SYNTAX XlinkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { xconnectIdEndA, slotIdEndA, portIdEndA, xconnectIdEndB, slotIdEndB, portIdEndB } ::= { xlinkCfgTable 1 } XlinkCfgEntry ::= SEQUENCE { xconnectIdEndA INTEGER, slotIdEndA INTEGER, portIdEndA INTEGER, xconnectIdEndB INTEGER, slotIdEndB INTEGER, portIdEndB INTEGER, xlinkConnectionType ConnectionType, xlinkRowStatus RowStatus, xlinkOpStatus OpStatus } xconnectIdEndA OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Xconnect id for one end. Can be any integer 1-65535. " ::= { xlinkCfgEntry 1 } slotIdEndA OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Slot Id of one end. " ::= { xlinkCfgEntry 2 } portIdEndA OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port id of one end. " ::= { xlinkCfgEntry 3 } xconnectIdEndB OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Xconnect id for the other end. Can be any integer 1-65535. " ::= { xlinkCfgEntry 4 } slotIdEndB OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Slot Id of the other end. " ::= { xlinkCfgEntry 5 } portIdEndB OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port id of the other end. " ::= { xlinkCfgEntry 6 } xlinkConnectionType OBJECT-TYPE SYNTAX ConnectionType ACCESS read-write STATUS mandatory DESCRIPTION "Connection Type between the Xconnects The possible options are : 1) Unchannelised DS3 (ut3) 2) Channelised DS3 (t3) " ::= { xlinkCfgEntry 7 } xlinkRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this XCONNECT Link. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3" ::= { xlinkCfgEntry 8 } xlinkOpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this XConnect Link. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { xlinkCfgEntry 9 } -- ************************************************* -- Xlink Management Table -- ************************************************* xlinkMgmntTable OBJECT-TYPE SYNTAX SEQUENCE OF XlinkMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "XLink Management Table. This table has six indices: xconnectIdEndA, slotIdEndA, portIdEndA,xconnectIdEndB, xconnectIdEndB,slotIdEndB,portIdEndB (all Integers) " ::= { xconnect 3 } xlinkMgmntEntry OBJECT-TYPE SYNTAX XlinkMgmntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { xconnIdEndA, xconnSlotIdEndA, xconnPortIdEndA, xconnIdEndB, xconnSlotIdEndB, xconnPortIdEndB } ::= { xlinkMgmntTable 1 } XlinkMgmntEntry ::= SEQUENCE { xconnIdEndA INTEGER, xconnSlotIdEndA INTEGER, xconnPortIdEndA INTEGER, xconnIdEndB INTEGER, xconnSlotIdEndB INTEGER, xconnPortIdEndB INTEGER, xlinkMgmntCmd EnableOperation } xconnIdEndA OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Xconnect id for one end. Can be any integer 1-65535. " ::= { xlinkMgmntEntry 1 } xconnSlotIdEndA OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Slot Id of one end. " ::= { xlinkMgmntEntry 2 } xconnPortIdEndA OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port id of one end. " ::= { xlinkMgmntEntry 3 } xconnIdEndB OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Xconnect id for the other end. Can be any integer 1-65535. " ::= { xlinkMgmntEntry 4 } xconnSlotIdEndB OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Slot Id of the other end. " ::= { xlinkMgmntEntry 5 } xconnPortIdEndB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port id of the other end. " ::= { xlinkMgmntEntry 6 } xlinkMgmntCmd OBJECT-TYPE SYNTAX EnableOperation ACCESS read-write STATUS mandatory DESCRIPTION "Management Command for Enabling/Disabling XLink The possible options are : 1) Enable 2) Disable [default] " ::= { xlinkMgmntEntry 7 } -- ************************************************* -- Cdr Config Group -- ************************************************* cdrConfig OBJECT IDENTIFIER ::= { switchCdr 1 } cdrBafConfig OBJECT IDENTIFIER ::= { switchCdr 2 } cdrFileConfig OBJECT IDENTIFIER ::= { switchCdr 3 } cdrFileInfo OBJECT IDENTIFIER ::= { switchCdr 4 } cdrMgmntCmdGroup OBJECT IDENTIFIER ::= { switchCdr 5 } -- ************************************************* -- CDR Configuaration Group -- ************************************************* cdrLongDurCallGenTime OBJECT-TYPE SYNTAX INTEGER(0..2359) ACCESS read-write STATUS mandatory DESCRIPTION "The Time of the day that the syatem will generate the long duration call. CDR Format ( HHMM ) Valid time of the day from 0000 - 2359 " ::= { cdrConfig 1 } -- ************************************************* -- CDR BAF Config Group -- ************************************************* cdrAppendModule801 OBJECT-TYPE SYNTAX Bool ACCESS read-write STATUS mandatory DESCRIPTION "Indicates if the Armillaire Proprietary Module 801 should be appended to those BAF Records. Text Format ( Not Case sensitive ) Valid values : yes, no " ::= { cdrBafConfig 1 } cdrSensorId OBJECT-TYPE SYNTAX INTEGER(1..999998) ACCESS read-write STATUS mandatory DESCRIPTION "AMA Sensor Id code of the switch. Valid values 000001-999998 for Set. If not configured then Default value is 0. " ::= { cdrBafConfig 2 } cdrRecordingOfficeId OBJECT-TYPE SYNTAX INTEGER(1..999998) ACCESS read-write STATUS mandatory DESCRIPTION "AMA Record Id code of the switch. Valid values 000001-999998 For Set. If not configured then Default value is 0. " ::= { cdrBafConfig 3 } -- ************************************************* -- CDR File Config Group -- ************************************************* cdrFileInterval OBJECT-TYPE SYNTAX INTEGER(1..86400) ACCESS read-write STATUS mandatory DESCRIPTION "How often the cdr file being generated. Valid values 1-86400 seconds " ::= { cdrFileConfig 1 } cdrFileRecLimit OBJECT-TYPE SYNTAX INTEGER(1..86400) ACCESS read-write STATUS mandatory DESCRIPTION "Maximum Nubler of BAF records in a CDR File. Valid values 1,677,215 " ::= { cdrFileConfig 2 } cdrFileSourceId OBJECT-TYPE SYNTAX INTEGER(1..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This Source Component id specifies the network element for receiving of cdr files according to AMADNS. This id will be part of first node of CDR filename. Valid values 01-4095 For Set. If not configured then Default value is 0. " ::= { cdrFileConfig 3 } cdrFileDestinationType OBJECT-TYPE SYNTAX INTEGER(1..15) ACCESS read-write STATUS mandatory DESCRIPTION "This Destination Component type specifies the network element for receiving of cdr files according to AMADNS. This type will be part of second node of CDR filename. Valid values 01-15 For Set. If not configured then Default value is 0. " ::= { cdrFileConfig 4 } cdrFileDestinationId OBJECT-TYPE SYNTAX INTEGER(1..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This Destination Component Id specifies the network element for receiving of cdr files according to AMADNS. This type will be part of second node of CDR filename. Valid values 01-4095 for Set. If not configured then Default value is 0. " ::= { cdrFileConfig 5 } -- ************************************************* -- CDR File Info Group -- ************************************************* cdrFileQuery OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of the desired CDR file. set file number to update the cdr file info. " ::= { cdrFileInfo 1 } cdrFileName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..24)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of the desired CDR file. Can be any combination of alphanumeric characters. Spaces are not allowed. Filename cannot exceed 24 characters. " ::= { cdrFileInfo 2 } cdrFileStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Status of the desired CDR file " ::= { cdrFileInfo 3 } cdrFileCreateDate OBJECT-TYPE SYNTAX DisplayString(SIZE(1..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Creation date of the desired CDR file FORMAT:2000/01/26 " ::= { cdrFileInfo 4 } cdrFileCreateTime OBJECT-TYPE SYNTAX DisplayString(SIZE(1..32)) ACCESS read-only STATUS mandatory DESCRIPTION "Creation time of the desired CDR file FORMAT: 20:12:23 " ::= { cdrFileInfo 5 } cdrFileRecordNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Record number of the desired CDR file " ::= { cdrFileInfo 6 } cdrFileAcknowledge OBJECT-TYPE SYNTAX DisplayString(SIZE(1..255)) ACCESS read-write STATUS mandatory DESCRIPTION "Acknowledgement of the CDR file. The input should be the File Name. " ::= { cdrFileInfo 7 } -- ************************************************* -- CDR Gen Management Cmd Group -- ************************************************* cdrGenMgmntCmd OBJECT-TYPE SYNTAX EnableOperation ACCESS read-write STATUS mandatory DESCRIPTION "This command is used to turn on the CDR generation for the entire switch.If switch CDR generation is enabled then CDR generation can be enabled/disabled on Trunk Group. The possible options are : 1) Enable 2) Disable [default] " ::= { cdrMgmntCmdGroup 1 } -- ************************************************* -- CDR Management Command For Trunk Group -- ************************************************* cdrMngmtTrnkGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF CdrMngmtTrnkGrpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "CDR Management Command for Trunk group Table. The index for this table is cdrTrnkGrpId (integer) " ::= { cdrMgmntCmdGroup 2 } cdrMngmtTrnkGrpEntry OBJECT-TYPE SYNTAX CdrMngmtTrnkGrpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { cdrTrnkGrpId } ::= { cdrMngmtTrnkGrpTable 1 } CdrMngmtTrnkGrpEntry ::= SEQUENCE { cdrTrnkGrpId INTEGER, cdrTrnkGrpdirection CdrFlag, cdrTrnkGrpMgmntCmd EnableOperation } cdrTrnkGrpId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The trunk Group Id. " ::= { cdrMngmtTrnkGrpEntry 1 } cdrTrnkGrpdirection OBJECT-TYPE SYNTAX CdrFlag ACCESS read-write STATUS mandatory DESCRIPTION "The Direction " ::= { cdrMngmtTrnkGrpEntry 2 } cdrTrnkGrpMgmntCmd OBJECT-TYPE SYNTAX EnableOperation ACCESS read-write STATUS mandatory DESCRIPTION "This command is used to turn on the CDR generation on the Trunk Group. The possible options are : 1) Enable 2) Disable [default] " ::= { cdrMngmtTrnkGrpEntry 3 } -- ************************************************* -- ModemFault Detection Table -- ************************************************* modemStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ModemStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Faulty Modem Detection Table. This Table provides information about all the potentially faulty modems in MSSC. This table has two indices: faultModemTrnkId and faultModemChnlId (both Integer) " ::= { modemFaultDetection 1 } modemStatusEntry OBJECT-TYPE SYNTAX ModemStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { faultModemTrnkId, faultModemChnlId } ::= { modemStatusTable 1 } ModemStatusEntry ::= SEQUENCE { faultModemTrnkId INTEGER, faultModemChnlId INTEGER, faultModemRepnum INTEGER, faultModemReset ModemResetStatus } faultModemTrnkId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The terminating Channel trunk Id. " ::= { modemStatusEntry 1 } faultModemChnlId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The terminating Channel Channel Id. " ::= { modemStatusEntry 2 } faultModemRepnum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Counter " ::= { modemStatusEntry 3 } faultModemReset OBJECT-TYPE SYNTAX ModemResetStatus ACCESS read-write STATUS mandatory DESCRIPTION "The Option for Reseting the terminating Channel. A 'GET' operation on this object will display the default value [no]. The possible option for 'SET' operation is 1) YES " ::= { modemStatusEntry 4 } -- ************************************************* -- LNP(Local Routing Number) -- ************************************************* lrnTable OBJECT-TYPE SYNTAX SEQUENCE OF LrnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Local Routing Number Table. This Table provides information about Local Routing number in MSSC. This table has the index lrnId (Integer) " ::= { lnp 1 } lrnEntry OBJECT-TYPE SYNTAX LrnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { lrnNum } ::= { lrnTable 1 } LrnEntry ::= SEQUENCE { lrnNum DisplayString, lrnRowStatus LrnRowStatus } lrnNum OBJECT-TYPE SYNTAX DisplayString(SIZE(1..10)) ACCESS read-write STATUS mandatory DESCRIPTION "The Local Routing Number (LRN) Id. " ::= { lrnEntry 1 } lrnRowStatus OBJECT-TYPE SYNTAX LrnRowStatus ACCESS read-write STATUS mandatory DESCRIPTION "The Local Routing Number (LRN) Number. " ::= { lrnEntry 2 } -- ************************************************* -- Switch DSP Config Table -- ************************************************* switchDSPCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SwitchDSPCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { switchDSP 1 } switchDSPCfgEntry OBJECT-TYPE SYNTAX SwitchDSPCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "DSP Configuration Table. This Table provides information about the DSP card(s) in MSSC. This table has two indices: switchDSPXconnId and switchDSPSlotId (both Integer) " INDEX { switchDSPXconnId, switchDSPSlotId } ::= { switchDSPCfgTable 1 } SwitchDSPCfgEntry ::= SEQUENCE { switchDSPXconnId INTEGER, switchDSPSlotId INTEGER, switchDSPCardType DSPCardType, switchDSPCfgRowStatus RowStatus, switchDSPCfgOpStatus OpStatus } switchDSPXconnId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Xconnect Id for which DSP card is being configured " ::= { switchDSPCfgEntry 1 } switchDSPSlotId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The Slot id at which the DSP card is being configured. " ::= { switchDSPCfgEntry 2 } switchDSPCardType OBJECT-TYPE SYNTAX DSPCardType ACCESS read-write STATUS mandatory DESCRIPTION "The card Type. The possible options are : 1) DSP2B 2) DSP2C " ::= { switchDSPCfgEntry 3 } switchDSPCfgRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "Current Status (configurational Status) of this Switch DSP. To Configure this Link, the only option is 'CREATEANDWAIT' To Delete this Link, the only option is 'DESTROY' For the 'GET' Operation, the possible options are 1) active 2) notinservice 3) n" ::= { switchDSPCfgEntry 4 } switchDSPCfgOpStatus OBJECT-TYPE SYNTAX OpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this Switch DSP. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { switchDSPCfgEntry 5 } -- ************************************************* -- Trunk Group Feature Table -- ************************************************* switchFeatureTGCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF SwitchFeatureTGCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Trunk Group Feature Table. This Table provides information about the Trunk Group Feature(s) in MSSC. This table has one indices: switchFeatureTGId (Integer) " ::= { switchTGFeature 1 } switchTGGrpCfgEntry OBJECT-TYPE SYNTAX SwitchFeatureTGCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { switchFeatureTGId } ::= { switchFeatureTGCfgTable 1 } SwitchFeatureTGCfgEntry ::= SEQUENCE { switchFeatureTGId INTEGER, switchFeatureTGName NameString, switchFeatureTGType TrnkGrpType, switchFeatureTGFeatureEC TGFeature, switchFeatureTGFeatureCOMPRESS TGFeature, switchFeatureTGFeatureSS TGFeature, switchFeatureTGFeatureCNIS TGFeature } switchFeatureTGId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Denotes Id for this trunk group. " ::= { switchTGGrpCfgEntry 1 } switchFeatureTGName OBJECT-TYPE SYNTAX NameString ACCESS read-only STATUS mandatory DESCRIPTION "Denotes Name of this trunk group. The Name is a string of length 8. The first two characters of Name have to be an alphabhet. The next 6 characters are numeric. An example of a valid Trunk Group Name is ab123456. NOTE: This format needs to strictly fo" ::= { switchTGGrpCfgEntry 2 } switchFeatureTGType OBJECT-TYPE SYNTAX TrnkGrpType ACCESS read-only STATUS mandatory DESCRIPTION "Denotes Trunk group type. Possible values for Trunk group are: 1. ss7 2. isdn " ::= { switchTGGrpCfgEntry 3 } switchFeatureTGFeatureEC OBJECT-TYPE SYNTAX TGFeature ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Echo Cancellation feature. Possible Values are: 1. Enable 2. Disable NOTE: If TrunkGrpType is ISDN, then Enabling Echo Cancellation feature is an INVALID Operation. A 'GET' Operation at this object will ALWAYS result in the default value [di" ::= { switchTGGrpCfgEntry 4 } switchFeatureTGFeatureCOMPRESS OBJECT-TYPE SYNTAX TGFeature ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Compression feature. Possible Values are: 1. Enable 2. Disable NOTE: if TrunkGrpType is ISDN, then Enabling Compression feature, is an INVALID Operation. A 'GET' Operation at this object will ALWAYS result in the default value [disable] bein" ::= { switchTGGrpCfgEntry 5 } switchFeatureTGFeatureSS OBJECT-TYPE SYNTAX TGFeature ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Silent Supression feature. Possible Values are: 1. Enable 2. Disable NOTE: If TrunkGrpType is ISDN, the Enabling Silent Supression feature, is an INVALID Operation. A 'GET' Operation at this object will ALWAYS result in the default value [di" ::= { switchTGGrpCfgEntry 6 } switchFeatureTGFeatureCNIS OBJECT-TYPE SYNTAX TGFeature ACCESS read-write STATUS mandatory DESCRIPTION "Denotes Caller Number Identitication Service (CNIS) feature. Possible Values are: 1. Enable 2. Disable NOTE: If TrunkGrpType is SS7, then Enabling Caller Number Identitication Service, is an INVALID Operation. A 'GET' Operation at this object will AL" ::= { switchTGGrpCfgEntry 7 } -- ************************************************* -- SwitchOver -- ************************************************* switchOver OBJECT-TYPE SYNTAX FTswitchOver ACCESS read-write STATUS mandatory DESCRIPTION "FT Switch Over command. The possible options are 1) FT_SIG 2) FT_ICC 3) FT_ISDN 4) FT_SPHR 5) FT_LM Select any one and set that option. " ::= { ftSwitchOverInfo 1 } -- ************************************************* -- LOG -- ************************************************* logGenTime OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "Switch Log Generation Time. The Parameter Time-interval determines the period of generating new log files. When the time interval is reached, all the current open log files are closed and new log files are generated for future log. The unit for the ti" ::= { logFileInfo 1 } logPurgeTime OBJECT-TYPE SYNTAX INTEGER(0..120) ACCESS read-write STATUS mandatory DESCRIPTION "Switch Log Deletion Time. The Parameter Time-interval determines the period of purging old log files. When the time interval is reached, all the log files older than this time-interval are deleted. The unit for the time-interval is 'minute'. " ::= { logFileInfo 2 } -- ************************************************* -- Log File Generation Enable -- ************************************************* enablelogGen OBJECT-TYPE SYNTAX LogFileEnDis ACCESS read-write STATUS mandatory DESCRIPTION "This option enables the log file Generation. 1) ALARM_LOG 2) AUDIT_LOG 3) MEAS_LOG 4) DIAG_LOG 5) SCRTY_LOG 6) EVENT_LOG 7) BILL_LOG 8) EMP_LOG 9) LOG_ALL Choose any one from drop down list... " ::= { logFileGenEnable 1 } disableLogGen OBJECT-TYPE SYNTAX LogFileEnDis ACCESS read-write STATUS mandatory DESCRIPTION "This option disables the log file Generation. 1) ALARM_LOG 2) AUDIT_LOG 3) MEAS_LOG 4) DIAG_LOG 5) SCRTY_LOG 6) EVENT_LOG 7) BILL_LOG 8) EMP_LOG 9) LOG_ALL Choose any one from drop down list.. " ::= { logFileGenEnable 2 } logAttribute OBJECT-TYPE SYNTAX LogFileAttr ACCESS read-write STATUS mandatory DESCRIPTION "Allows the user to inquire about the current LOG file attributes. The possible options are : 1) ALARM_LOG 2) AUDIT_LOG 3) MEAS_LOG 4) DIAG_LOG 5) SCRTY_LOG 6) EVENT_LOG 7) BILL_LOG 8) EMP_LOG Choose any one from drop down list.. " ::= { logFileAttribute 1 } logFileSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { logFileAttribute 2 } logFileDuration OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { logFileAttribute 3 } logFileStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { logFileAttribute 4 } -- ************************************************* -- SS7 Link Trace Information Group -- ************************************************* ss7LnkTraceTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7LnkTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This Table is specified for Applying Trace Function for any SS7 Link(s). The index of this table is ss7LnkId (integer) " ::= { ss7LnkTrace 1 } ss7LnkTraceEntry OBJECT-TYPE SYNTAX Ss7LnkTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { ss7LnkId } ::= { ss7LnkTraceTable 1 } Ss7LnkTraceEntry ::= SEQUENCE { ss7LnkId INTEGER, ss7LnkLog LogType, ss7LnkEnable EnableTrace } ss7LnkId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The SS7 link Id on which the Trace Function is to be applied. " ::= { ss7LnkTraceEntry 1 } ss7LnkLog OBJECT-TYPE SYNTAX LogType ACCESS read-only STATUS mandatory DESCRIPTION "This option displays weather log Function is enabled for the specified SS7 Link. " ::= { ss7LnkTraceEntry 2 } ss7LnkEnable OBJECT-TYPE SYNTAX EnableTrace ACCESS read-write STATUS mandatory DESCRIPTION "This option enables/disables the trace Function for the specified SS7 Link. The possible option are: 1) Enable 2) Disable [default] " ::= { ss7LnkTraceEntry 3 } -- ************************************************* -- SS7 Route trace Info Group -- ************************************************* ss7RouteTraceTable OBJECT-TYPE SYNTAX SEQUENCE OF Ss7RouteTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This Table is specified for Applying Trace Function for any SS7 Route(s). The index of this table is ss7RouteDpc (Integer) " ::= { ss7RouteTrace 1 } ss7RouteTraceEntry OBJECT-TYPE SYNTAX Ss7RouteTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { ss7RouteDpc } ::= { ss7RouteTraceTable 1 } Ss7RouteTraceEntry ::= SEQUENCE { ss7RouteDpc INTEGER, ss7RouteLog LogType, ss7RouteEnable EnableTrace } ss7RouteDpc OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The SS7 Point code. The trace Function is to be applied on this route. " ::= { ss7RouteTraceEntry 1 } ss7RouteLog OBJECT-TYPE SYNTAX LogType ACCESS read-only STATUS mandatory DESCRIPTION "This option displays weather Log Function is enabled for the specified SS7 Route. " ::= { ss7RouteTraceEntry 2 } ss7RouteEnable OBJECT-TYPE SYNTAX EnableTrace ACCESS read-write STATUS mandatory DESCRIPTION "This option enables/disables the trace Functions for the specified SS7 Route. The possible option are: 1) Enable 2) Disable [default] " ::= { ss7RouteTraceEntry 3 } -- ************************************************* -- ISDN Trunk Trace Info Group -- ************************************************* isdnTrunkTraceTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdntrunkTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This Table is specified for Applying Trace Function for any ISDN Trunk(s). The index of this table is isdnTrnkId (Integer) " ::= { isdnTrnkTrace 1 } isdnTrunkTraceEntry OBJECT-TYPE SYNTAX IsdntrunkTraceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { isdnTrnkId } ::= { isdnTrunkTraceTable 1 } IsdntrunkTraceEntry ::= SEQUENCE { isdnTrnkId INTEGER, isdnTrunkLog LogType, isdnTrunkEnable EnableTrace } isdnTrnkId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The ISDN Trunk Id for which the Trace Function is to be applied. " ::= { isdnTrunkTraceEntry 1 } isdnTrunkLog OBJECT-TYPE SYNTAX LogType ACCESS read-only STATUS mandatory DESCRIPTION "This option displays weather log Function is enabled for the specified ISDN Trunk. " ::= { isdnTrunkTraceEntry 2 } isdnTrunkEnable OBJECT-TYPE SYNTAX EnableTrace ACCESS read-write STATUS mandatory DESCRIPTION "This option enables/disables the trace Functions for the specified ISDN Trunk. The possible option are: 1) Enable 2) Disable [default] " ::= { isdnTrunkTraceEntry 3 } -- ************************************************* -- Audit ISDN Trunk -- ************************************************* auditISDNTrnkTable OBJECT-TYPE SYNTAX SEQUENCE OF AuditISDNTrnkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Audit ISDN Trunk Table. This table has one index: auditTrnkId (Integer) " ::= { auditInfo 1 } auditISDNTrnkCfgEntry OBJECT-TYPE SYNTAX AuditISDNTrnkCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " INDEX { auditTrnkId } ::= { auditISDNTrnkTable 1 } AuditISDNTrnkCfgEntry ::= SEQUENCE { auditTrnkId INTEGER, auditISDNTrnk AuditOperation } auditTrnkId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The ISDN Trunk Id on which the audit operation is being applied. " ::= { auditISDNTrnkCfgEntry 1 } auditISDNTrnk OBJECT-TYPE SYNTAX AuditOperation ACCESS read-write STATUS mandatory DESCRIPTION "This Object is set to Apply Audit on this particular ISDN Trunk. The possible option for 'SET' is 1) audit A 'GET' Operation on this object would result the default value 'no action' being displayed. " ::= { auditISDNTrnkCfgEntry 2 } -- ************************************************* -- Audit Xlink -- ************************************************* auditXLink OBJECT-TYPE SYNTAX AuditOperation ACCESS read-write STATUS mandatory DESCRIPTION "This option audits the All the existing XLinks. " ::= { auditInfo 2 } -- ************************************************* -- Audit DPC -- ************************************************* auditDPCTable OBJECT-TYPE SYNTAX SEQUENCE OF AuditDPCCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current Entry Containes all the objects for this Table. This object is not-accessible, but the user can access all the objects in this table at the next level. " ::= { auditInfo 3 } auditDPCCfgEntry OBJECT-TYPE SYNTAX AuditDPCCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { auditPointCode } ::= { auditDPCTable 1 } AuditDPCCfgEntry ::= SEQUENCE { auditPointCode INTEGER, auditPointCodeType AuditType, auditDPC AuditOperation } auditPointCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Point Code on which the audit operation is being applied. " ::= { auditDPCCfgEntry 1 } auditPointCodeType OBJECT-TYPE SYNTAX AuditType ACCESS read-only STATUS mandatory DESCRIPTION "The Point Code Type. Ansi/Itu. " ::= { auditDPCCfgEntry 2 } auditDPC OBJECT-TYPE SYNTAX AuditOperation ACCESS read-write STATUS mandatory DESCRIPTION "This Object is set to Apply Audit on this particular DPC. The possible option for 'SET' is 1) audit A 'GET' Operation on this object would result the default value 'no action' being displayed. " ::= { auditDPCCfgEntry 3 } -- ************************************************* -- Audit Period -- ************************************************* auditPeriodGrp OBJECT IDENTIFIER ::= { auditInfo 4 } -- ************************************************* -- Audit Info table -- ************************************************* auditTimePeriod OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The Audit Period for which the audit operation is being applied. " ::= { auditPeriodGrp 1 } auditPeriod OBJECT-TYPE SYNTAX AuditOperation ACCESS read-write STATUS mandatory DESCRIPTION "This Object is set to Apply Audit for this particular Period. The possible option for 'SET' is 1) audit A 'GET' Operation on this object would result the default value 'no action' being displayed. " ::= { auditPeriodGrp 2 } -- ************************************************* -- Process Status -- ************************************************* statusLM1ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of FT_LM: Process Id 512. " ::= { processStatusInfo 1 } statusLM2ProcID OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of FT_LM: Process Id 511. " ::= { processStatusInfo 2 } statusICC1ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of FT_ICC : Process Id 480. " ::= { processStatusInfo 3 } statusICC2ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of FT_ICC: Process Id 496. " ::= { processStatusInfo 4 } statusISDN1ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of FT_ISDN: Process Id 476. " ::= { processStatusInfo 5 } statusISDN2ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of FT_ISDN: Process Id 472. " ::= { processStatusInfo 6 } statusSPHR1ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of FT_SPHR: Process Id 448. " ::= { processStatusInfo 7 } statusSPHR2ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of FT_SPHR: Process Id 464. " ::= { processStatusInfo 8 } statusSIG1ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of FT_SIG: Process Id 384. " ::= { processStatusInfo 9 } statusSIG2ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of FT_SIG: Process Id 400. " ::= { processStatusInfo 10 } statusMTP21ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of Mtp2: Process Id 320. " ::= { processStatusInfo 11 } statusMTP22ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of Mtp2: Process Id 321. " ::= { processStatusInfo 12 } statusMTP23ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of Mtp2 : Process Id 322. " ::= { processStatusInfo 13 } statusMTP24ProcId OBJECT-TYPE SYNTAX ProcessStatus ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current status of Mtp2: Process Id 323. " ::= { processStatusInfo 14 } -- ************************************************* -- NMS Status -- ************************************************* ethernetConnStatus OBJECT-TYPE SYNTAX EthernetConnStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status of the Ethernet Connection to MSSC. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down " ::= { ethernetConnStatusInfo 1 } -- ************************************************* -- Trap Objects -- ************************************************* trapOpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the point code of the switch that send trap " ::= { trapObjects 1 } trapXconnectId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the id of the xconnect that send trap " ::= { trapObjects 2 } trapLinkId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the id of the link that abnormal situation " ::= { trapObjects 3 } trapSlotId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the id of the slot that has abnormal situation " ::= { trapObjects 4 } trapPortId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the id of the port that has abnormal situation " ::= { trapObjects 5 } trapTrunkId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the id of the trunk that has abnormal situation " ::= { trapObjects 6 } trapInterfaceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the id of the interface that has abnormal situation " ::= { trapObjects 7 } trapChnlId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the id of the channel that has abnormal situation " ::= { trapObjects 8 } trapDbId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the id of the database that has abnormal situation " ::= { trapObjects 9 } trapLinkName OBJECT-TYPE SYNTAX NameString ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the name of the link that has abnormal situation " ::= { trapObjects 10 } trapSwitchName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the name " ::= { trapObjects 11 } trapCicvalue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate Circuit Identification Code value. " ::= { trapObjects 12 } trapCicrange OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Integer identifying the range ex. no. cics. " ::= { trapObjects 13 } trapCause OBJECT-TYPE SYNTAX DisplayString(SIZE(1..33)) ACCESS read-only STATUS mandatory DESCRIPTION "Cause indicates Causes for ISUP related alarms: BLOCKING UNBLOCKING INVALIDRNG GROUPBLOCKING GROUPUNBLOCKACK RESETCIRCUIT RESETRELCOMP GROUPRESETCIRCUIT GROUPRESETACK CIRCUITQUERYRESP VALIDATIONSUCCESS VALIDATIONFAILED VALIDATIONFAILEDWRONGCLLI OTHERS" ::= { trapObjects 14 } trapDpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the point code of the switch " ::= { trapObjects 15 } trapCdrFileSeqNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the sequence number of the cdr file that has abnormal situation " ::= { trapObjects 16 } trapCdrFileName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the CDR file name or file directory. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 255 characters. " ::= { trapObjects 17 } trapMeasErrCause OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the Measurement Files error operation cause " ::= { trapObjects 18 } trapMeasErrNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the Measurement Files error number of the operation " ::= { trapObjects 19 } trapRepeatNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the count that trap has occured " ::= { trapObjects 20 } trapSeverity OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the severity of the sent trap " ::= { trapObjects 21 } trapProcessId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the process id for that trap has occured " ::= { trapObjects 22 } trapBucketSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the process Bucket size for the Process for which the trap has occured " ::= { trapObjects 23 } trapNode1Id OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the src Xconnect Id which cause congestion " ::= { trapObjects 24 } trapNode2Id OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the dest Xconnect Id which cause congestion " ::= { trapObjects 25 } trapRoutename OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "indicate the xoute name that is not found between the xlink " ::= { trapObjects 26 } trapMeasFileName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "indicate the Measurement file name. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 64 characters. " ::= { trapObjects 27 } trapDirectory OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "indicate the Cdr File Directory " ::= { trapObjects 28 } trapProcessorId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the Process Id " ::= { trapObjects 29 } trapLogFileName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the Log file name. Can be any combination of alphanumeric characters. Spaces are allowed and cannot exceed 64 characters. " ::= { trapObjects 30 } trapLogErrcause OBJECT-TYPE SYNTAX DisplayString(SIZE(1..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the Log error operation cause " ::= { trapObjects 31 } trapLogErrNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the log cdr error number of the operation " ::= { trapObjects 32 } trapPsuNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the Power supply number " ::= { trapObjects 33 } trapIntId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the Power supply number " ::= { trapObjects 34 } trapIntfcId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the Power supply number " ::= { trapObjects 35 } trapLanId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate theLan ID " ::= { trapObjects 36 } trapnumXlinks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the no of existing links " ::= { trapObjects 37 } trapSwitchId1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the xconnect Id " ::= { trapObjects 38 } trapSwitchId2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the xconnect Id " ::= { trapObjects 39 } trapProcInstNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the Process instance number " ::= { trapObjects 40 } trapProcName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..15)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the Process name that Failed " ::= { trapObjects 41 } trapFanNo OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicate the Fan Number " ::= { trapObjects 42 } trapUserName OBJECT-TYPE SYNTAX NameString ACCESS read-only STATUS mandatory DESCRIPTION "indicates the user login Name " ::= { trapObjects 43 } trapBitMapStatus OBJECT-TYPE SYNTAX DisplayString(SIZE(1..33)) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the Bit Map Status of the Cics that are blocked. This Status is only valid for GROUPBLOCKING (I.e range >1)" ::= { trapObjects 44 } -- ************************************************* -- Alarm Group -- ************************************************* alarmTraps OBJECT IDENTIFIER ::= { alarmGrp 1 } -- ************************************************* -- Alarm Traps Group -- ************************************************* genswitchSnmpAgentReadyNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName } DESCRIPTION "Info : SNMP Agent is up " ::= 1 genConsoleLoginNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapUserName } DESCRIPTION "Info : A user has successfully logged in from console " ::= 2 genConsoleLogoutNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapUserName } DESCRIPTION "Info : A user has successfully logged out from console " ::= 3 genProcessBufOverflowNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName, trapProcInstNo, trapBucketSize } DESCRIPTION "Info : Process ran out of buffer " ::= 4 genProcessBufOverflowRecoverNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName, trapProcInstNo, trapBucketSize } DESCRIPTION "Info : Process Recovered from Buffer Overflow " ::= 5 genProcessHeapOverFlowNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName, trapProcInstNo } DESCRIPTION "Info : Process Heap OverFlow Detected " ::= 6 genProcessHeapOverFlowRecoverNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName, trapProcInstNo } DESCRIPTION "Info : Recovered from Process Heap Overflow " ::= 7 xconnectUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapXconnectId } DESCRIPTION "Info : switch has successfully brought up TCP/IP link between MSCG and AC 120 xconnect " ::= 8 xconnectDnNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapXconnectId } DESCRIPTION "Info : switch has a failure on TCP/IP link between MSCG and AC120 " ::= 9 xconnectClkClearNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Stratum Card is available " ::= 10 xconnectClkFailNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Stratum Card has either been removed or has failed " ::= 11 xconnectBkplaneRefClkClearNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapXconnectId } DESCRIPTION "Info : Back Plane reference clock clear " ::= 12 xconnectBkplaneRefClkFailNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Back Plane reference clock fail " ::= 13 xconnectInterfaceInServiceNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Switch has successfully brought the specified interface to be in service " ::= 14 xconnectInterfaceOutOfServiceNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : An interface card is out of service " ::= 15 xconnectCardInsertionNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapXconnectId } DESCRIPTION "Info : A card is inserted in xconnect " ::= 16 xconnectCardRemovalNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapXconnectId } DESCRIPTION "Info : A card is removed from xconnect " ::= 17 xconnectIllegalCardTypeNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapXconnectId } DESCRIPTION "Info : Illegal Card Type " ::= 18 xconnectIntfFarEndLOFNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Interface Far end LOF " ::= 19 xconnectIntfFarEndAISNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Interface Far end AIS " ::= 20 xconnectIntfNearEndLOFNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Interface Near end LOF " ::= 21 xconnectIntfNearEndLOSNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Interface Near end LOS " ::= 22 xconnectIntfCreateNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Interface in AC120 has been created " ::= 23 xconnectIntfDeleteNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Interface in AC120 has been deleted " ::= 24 xconnectXlinkAdjConClrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapNode1Id, trapNode2Id, trapnumXlinks } DESCRIPTION "Info : Xconnect Adjacent Congestion cleared " ::= 25 xconnectXlinkAdjConNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapNode1Id, trapNode2Id, trapnumXlinks } DESCRIPTION "Info : Xconnect Adjacent Congestion Notified " ::= 26 xconnectXlinkRouteFailNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapNode1Id, trapNode2Id } DESCRIPTION "Info : Xpath not found between the Xlink " ::= 27 xconnectPortUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : Port is Up " ::= 28 xconnectCPUSwitchOverNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapXconnectId } DESCRIPTION "Info : XConnect CPU SwitchOver " ::= 29 atmRAINotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : ATM Remote Alarm Indication " ::= 30 atmAISNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : ATM AIS " ::= 31 atmLOFNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : ATM LOF " ::= 32 atmLOSNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapSlotId, trapPortId, trapXconnectId } DESCRIPTION "Info : ATM LOS " ::= 33 mfdClearNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapTrunkId, trapChnlId } DESCRIPTION "Info : A potential fault modem is cleared " ::= 34 mfdDetectionNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapRepeatNum, trapTrunkId, trapChnlId } DESCRIPTION "Info : Faulty Modem: A Potential Faulty Modem has been Detected " ::= 35 measFileReadyNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapMeasFileName } DESCRIPTION "Info : Measurement file is ready for FTP " ::= 36 measDiskOverCrtclThresholdNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapMeasErrCause, trapMeasErrNum } DESCRIPTION "Info : The partition that the measurement file resides on is over critical threshold. " ::= 37 measFileMoveNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapMeasFileName } DESCRIPTION "Info : Measurement file moved to secondary directory " ::= 38 measFileMoveErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapMeasFileName } DESCRIPTION "Info : Error in moving Measurement file to secondary directory " ::= 39 measFileOpenErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapMeasFileName } DESCRIPTION "Info : Measurement open file error " ::= 40 measFileDeleteNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapMeasFileName } DESCRIPTION "Info : Measurement file deleted " ::= 41 measFileDeleteErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapMeasFileName } DESCRIPTION "Info : Measurement delete file error " ::= 42 cdrFileReadyNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info :Cdr file is ready for Polling " ::= 43 cdrDiskFullNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDirectory } DESCRIPTION "Info :CDR file disk usage reach critical threshold " ::= 44 cdrFileOpenErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info :CDR open file error " ::= 45 cdrFileMoveErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info : Error in moving CDR file from temp location to target CDR file location " ::= 46 cdrDeleteErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info : CDR file cannot be deleted " ::= 47 cdrWriteHeaderErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info :Error in writing CDR file header " ::= 48 cdrWriteRecErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info :Error in writing CDR record " ::= 49 cdrErrFileLocErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info: Invalid Cdr Directory " ::= 50 cdrErrTempFileLocErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info: Invalid Cdr Directory " ::= 51 cdrFileSysErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info: Cdr File System Operation error. " ::= 52 cdrFileCloseErrNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info: Error in closing CDR file " ::= 53 cdrFileDelete5DaysNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Info: cdr files created within past 5 days are deleted " ::= 54 ss7LinkUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : switch has successfully brought up ss7 mtp3 link " ::= 55 ss7LinkDnNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : switch has a failure on ss7 mtp3 link " ::= 56 ss7Mtp2LinkUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : switch has successfully brought up ss7 mtp2 link " ::= 57 ss7Mtp2LinkDnNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : switch has a failure on ss7 mtp2 link " ::= 58 ss7LinkEnterCongestionNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : the specified link has entered a congestion situation " ::= 59 ss7LinkExitCongestionNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : the ss7 link has exited the congestion situation " ::= 60 ss7InvalidSLCNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDpc } DESCRIPTION "Info : Mtp3 invalid SLC configured. " ::= 61 ss7ConcernedDpcPauseNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDpc } DESCRIPTION "Info : Concerned DPC pause " ::= 62 ss7ConcernedDpcResumeNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDpc } DESCRIPTION "Info : Concerned DPC resume " ::= 63 ss7ConcernedDpcRemUnAvailNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDpc } DESCRIPTION "Info : Concerned DPC remote user unavailable " ::= 64 ss7LinkRemInhNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : Link Inhibited Remotely " ::= 65 ss7LinkRemUnInhNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : Link UnInhibited Remotely " ::= 66 ss7LinkLocInhNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : Link Inhibited Locally " ::= 67 ss7LinkLocUnInhNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : Link UnInhibited Locally " ::= 68 ss7LinkLOPBlkNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : Local Processor Recovered causing link unblocked " ::= 69 ss7LinkLPRNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : Local Processor Recovered causing link unblocked " ::= 70 ss7LinkRPONotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info :LSSU/SIPO Received " ::= 71 ss7LinkRPRNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info :LSSU/SIPO stopped and FISU/MSU recived " ::= 72 ss7IsupCicLocNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDpc, trapCicvalue, trapCicrange, trapCause } DESCRIPTION "Info : ISUP Circuits are blocked/unblocked locally " ::= 73 ss7IsupCicRemNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDpc, trapCicvalue, trapCicrange, trapCause } DESCRIPTION "Info : ISUP Circuits are blocked/unblocked remotely " ::= 74 ss7IsupCongLvl1Notify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDpc } DESCRIPTION "Info : Route to DPC is encountering Level 1 Congestion " ::= 75 ss7IsupCongLvl2Notify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDpc } DESCRIPTION "Info : Route to DPC is encountering Level 2 Congestion " ::= 76 isdnDChnlUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapXconnectId, trapSlotId, trapPortId } DESCRIPTION "Info : An ISDN D-channel is Up " ::= 77 isdnDChnlDnNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapXconnectId, trapSlotId, trapPortId } DESCRIPTION "Info : An ISDN D-channel is down " ::= 78 logFileReadyNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLogFileName } DESCRIPTION "Info : Logger file is ready " ::= 79 logDiskFull60PercentNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLogErrcause, trapLogErrNo } DESCRIPTION "Info : Log Files occupy 60% of disk quota " ::= 80 logDiskFull70PercentNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLogErrcause, trapLogErrNo } DESCRIPTION "Info : Log Files occupy 70% of disk quota " ::= 81 logDiskFull80PercentNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLogErrcause, trapLogErrNo } DESCRIPTION "Info : Log Files occupy 80% of disk quota " ::= 82 logErrFileOpenNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLogFileName } DESCRIPTION "Info : Log file open error " ::= 83 logErrFileCloseNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLogFileName } DESCRIPTION "Info : Log file close error " ::= 84 logErrFileDeleteNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLogFileName } DESCRIPTION "Info : Log file cannot be deleted " ::= 85 logErrFileWriteNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLogFileName } DESCRIPTION "Info : Log manager cannot write to log file " ::= 86 msscPriDedicatedLinkUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : Dedicated link between the 2 Netra machine is UP " ::= 87 msscPriDedicatedLinkDownNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : Dedicated link between the 2 Netra machine is down " ::= 88 msscSecDedicatedLinkUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info : Dedicated link between the 2 Netra machine is UP " ::= 89 msscSecDedicatedLinkDownNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLinkId } DESCRIPTION "Info :Dedicated link between the 2 Netra machine is down " ::= 90 msscPriPsuUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapPsuNo } DESCRIPTION "Info : Primary hosts power supply up " ::= 91 msscPriPsuDownNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapPsuNo } DESCRIPTION "Info : Primary hosts power supply down " ::= 92 msscBakPsuUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapPsuNo } DESCRIPTION "Info : Backup hosts power supply up " ::= 93 msscBakPsuDownNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapPsuNo } DESCRIPTION "Info : Backup hosts power supply down " ::= 94 msscPriLanPhyIntfUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLanId } DESCRIPTION "Info : Primary Physical LAN Interface Up " ::= 95 msscPriLanPhyIntfDownNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLanId } DESCRIPTION "Info : Primary Physical LAN Interface Down " ::= 96 msscSecLanPhyIntfUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLanId } DESCRIPTION "Info : Secondary physical LAN Interface Up " ::= 97 msscSecLanPhyIntfDownNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLanId } DESCRIPTION "Info : Secondary Physical LAN Interface Down " ::= 98 msscPriHostFanUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapFanNo } DESCRIPTION "Info : Primary Fan Up " ::= 99 msscPriHostFanDownNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapFanNo } DESCRIPTION "Info : Primary Fan Down " ::= 100 msscBckHostFanUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapFanNo } DESCRIPTION "Info : Backup Fan Up " ::= 101 msscBckHostFanDownNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapFanNo } DESCRIPTION "Info : Backup Fan Down " ::= 102 hubPriIntfUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLanId } DESCRIPTION "Info : Primary Interface Up " ::= 103 hubPriIntfDownNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLanId } DESCRIPTION "Info : Primary Interface down " ::= 104 hubSecIntfUpNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLanId } DESCRIPTION "Info : Secondary Interface Up " ::= 105 hubSecIntfDownNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapLanId } DESCRIPTION "Info : Secondary Interface Down " ::= 106 ftProcessAbnormalTerminationNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName, trapProcInstNo } DESCRIPTION "Info : Process abnormal termination " ::= 107 ftProcessRestartConfigSucceededNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName, trapProcInstNo } DESCRIPTION "Info : Process abnormal termination " ::= 108 ftProcessRestartConfigFailedNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName, trapProcInstNo } DESCRIPTION "Info : Process abnormal termination " ::= 109 ftMsscFtmupNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName } DESCRIPTION "Info : Process abnormal termination " ::= 110 ftControlSwitchOverSucceededNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName } DESCRIPTION "Info : Control SwitchOver Successful " ::= 111 ftControlSwitchOverFailedNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName } DESCRIPTION "Info : Control SwitchOver Failure " ::= 112 ftForcedSwitchOverSucceededNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName } DESCRIPTION "Info : Forced SwitchOver Successful " ::= 113 ftForcedSwitchOverFailedNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName } DESCRIPTION "Info : Forced SwitchOver Failure " ::= 114 ftProcessRestartDisableNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapProcName, trapProcInstNo } DESCRIPTION "" ::= 115 updateDBAuditOpStatNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName } DESCRIPTION "Info : Updated the Database for Audited Related Operational Status " ::= 116 isupIccAuditNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName } DESCRIPTION "ISUP ICC Audit Notify" ::= 117 cdrDiskFullMinorNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDirectory } DESCRIPTION "CDR Disk Usage reached Minor Threshold" ::= 118 cdrDiskFullMajorNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDirectory } DESCRIPTION "CDR Disk Usage reached Major Threshold" ::= 119 cdrErrMoveCdrNackNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "Invalid CDR file Non-Ack Directory" ::= 120 cdrFileMoveCdrNackNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapCdrFileName } DESCRIPTION "CDR file moved to Non-Ack Directory" ::= 121 ss7CktValidationNotify TRAP-TYPE ENTERPRISE alarmTraps VARIABLES { trapSeverity, trapOpc, trapSwitchName, trapDpc, trapCicvalue, trapCause } DESCRIPTION "Validation of Circuits" ::= 122 -- ************************************************* -- Active Alarm List -- ************************************************* switchActiveAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF SwitchActiveAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { alarmGrp 2 } switchActiveAlarmEntry OBJECT-TYPE SYNTAX SwitchActiveAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { switchAlarmMsgId, switchAlarmInstNo } ::= { switchActiveAlarmTable 1 } SwitchActiveAlarmEntry ::= SEQUENCE { switchAlarmMsgId INTEGER, switchAlarmInstNo INTEGER, switchAlarmTime DisplayString, switchAlarmType EventType, switchAlarmMainEvent AlarmEvent, switchAlarmSubEvent AlarmSubEvent, switchAlarmId INTEGER, switchAlarmSeverity AlarmSeverity, switchAlarmDesc DisplayString, switchAlarmAck ActiveAlarmAckStatus, switchAlarmRepeatTime INTEGER } switchAlarmMsgId OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm Message Id. Can be any integer from 1-65535. " ::= { switchActiveAlarmEntry 1 } switchAlarmInstNo OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Instance number related to alarm. Can be any integer from 1-65535. " ::= { switchActiveAlarmEntry 2 } switchAlarmTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Date and time when the alarma was generated " ::= { switchActiveAlarmEntry 3 } switchAlarmType OBJECT-TYPE SYNTAX EventType ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the event group is alarm. Default :ALARM " ::= { switchActiveAlarmEntry 4 } switchAlarmMainEvent OBJECT-TYPE SYNTAX AlarmEvent ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the main event event group of alarm " ::= { switchActiveAlarmEntry 5 } switchAlarmSubEvent OBJECT-TYPE SYNTAX AlarmSubEvent ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the main event event group of alarm " ::= { switchActiveAlarmEntry 6 } switchAlarmId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the alarm that was sent " ::= { switchActiveAlarmEntry 7 } switchAlarmSeverity OBJECT-TYPE SYNTAX AlarmSeverity ACCESS read-only STATUS mandatory DESCRIPTION "This field defines the severity of alarms of alarm. Alarms can od : Major,Minor,Critical and Informational " ::= { switchActiveAlarmEntry 8 } switchAlarmDesc OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This description related to Generated alarm " ::= { switchActiveAlarmEntry 9 } switchAlarmAck OBJECT-TYPE SYNTAX ActiveAlarmAckStatus ACCESS read-write STATUS mandatory DESCRIPTION "This field is to acknowelge the alarms manually " ::= { switchActiveAlarmEntry 10 } switchAlarmRepeatTime OBJECT-TYPE SYNTAX INTEGER(0..60) ACCESS read-write STATUS mandatory DESCRIPTION "Alarm Repeat Time in minutes: After the set time all alarms in the active alarm table will be displayed to the user again " ::= { switchActiveAlarmEntry 11 } -- ************************************************* -- This MIB was Automatically Generated -- ************************************************* END