-- Version 2.15.1.1, modified 2001-05-31 17:27:22-04 BRI-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, Gauge, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Codex MIB Group definitions codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } -- This MIB is Branch Node (BN) specific. -- Textual conventions DisplayString ::= OCTET STRING cdx6500PPCTISDN OBJECT IDENTIFIER ::= { cdx6500PCTPortProtocolGroup 26 } cdx6500PPCTBRIConfig OBJECT IDENTIFIER ::= { cdx6500PPCTISDN 1 } cdx6500PPCTBRIPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPCTBRIPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains BRI Port configuration parameters" ::= { cdx6500PPCTBRIConfig 1 } cdx6500PPCTBRIPortEntry OBJECT-TYPE SYNTAX Cdx6500PPCTBRIPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each PortEntry contains the configuration parameters for one BRI ISDN port." INDEX { cdx6500BRICfgPortNumber } ::= { cdx6500PPCTBRIPortTable 1 } Cdx6500PPCTBRIPortEntry ::= SEQUENCE { cdx6500BRICfgPortNumber INTEGER, cdx6500BRICfgPortType INTEGER, cdx6500BRICfgSwitchType DisplayString, cdx6500BRICfgVmebug INTEGER, cdx6500BRICfgTEI INTEGER } cdx6500BRICfgPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the port." ::= { cdx6500PPCTBRIPortEntry 1 } cdx6500BRICfgPortType OBJECT-TYPE SYNTAX INTEGER { bri (40) } ACCESS read-only STATUS mandatory DESCRIPTION "The Port Type of the port." ::= { cdx6500PPCTBRIPortEntry 2 } cdx6500BRICfgSwitchType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies switch type for the central office. VN4 - French VN4 standard 1TR6 - German switch standard BTNR - UK Standard ETSI - Euro-ISDN 5ESS - AT&T switch NI-1 - National ISDN version 1." ::= { cdx6500PPCTBRIPortEntry 3 } cdx6500BRICfgVmebug OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Engineering use only. Enable/disable the running of the OST VMEBUG debugger. NOTE: For this to work the flash must be loaded with the dbg_vmebug file. If the the dbg_vmebug file is not in flash this parameter will have no effect." ::= { cdx6500PPCTBRIPortEntry 4 } cdx6500BRICfgTEI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The range is 0..63,127. The range 0..63 indicate a static TEI provided by the Network subscribing. 127: TEI negotiated." ::= { cdx6500PPCTBRIPortEntry 5 } cdx6500PPCTBRIChan OBJECT IDENTIFIER ::= { cdx6500PPCTBRIConfig 2 } cdx6500PPCTBRIX25ChanTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPCTBRIX25ChanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains BRI Channel configuration parameters." ::= { cdx6500PPCTBRIChan 1 } cdx6500PPCTBRIX25ChanEntry OBJECT-TYPE SYNTAX Cdx6500PPCTBRIX25ChanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each ChanEntry contains the configuration parameters for one BRI ISDN channel." INDEX { cdx6500BRIX25ChanCfgPortNumber, cdx6500BRIX25ChanCfgChannelNum } ::= { cdx6500PPCTBRIX25ChanTable 1 } Cdx6500PPCTBRIX25ChanEntry ::= SEQUENCE { cdx6500BRIX25ChanCfgPortNumber INTEGER, cdx6500BRIX25ChanCfgChannelNum INTEGER, cdx6500BRIX25ChanCfgChannelType INTEGER, cdx6500BRIX25ChanCfgAccessType INTEGER, cdx6500BRIX25ChanCfgTimeslot INTEGER, cdx6500BRIX25ChanCfgSPID DisplayString, cdx6500BRIX25ChanCfgISDNCallAcc INTEGER, cdx6500BRIX25ChanCfgLocalSubsAddr DisplayString, cdx6500BRIX25ChanCfgLocalSubsSubAddr DisplayString, cdx6500BRIX25ChanCfgRateAdaption INTEGER, cdx6500BRIX25ChanCfgProtocolType INTEGER, cdx6500BRIX25ChanCfgLinkAddr INTEGER, cdx6500BRIX25ChanCfgNumPVCChannels INTEGER, cdx6500BRIX25ChanCfgStartPVCChanNum INTEGER, cdx6500BRIX25ChanCfgBNumSVCChannels INTEGER, cdx6500BRIX25ChanCfgStartSVCChanNum INTEGER, cdx6500BRIX25ChanCfgInitialFrame INTEGER, cdx6500BRIX25ChanCfgT1TransRetryTimer INTEGER, cdx6500BRIX25ChanCfgT4PollTimer INTEGER, cdx6500BRIX25ChanCfgBN2TransTries INTEGER, cdx6500BRIX25ChanCfgFrameSeqCount INTEGER, cdx6500BRIX25ChanCfgBKFrameWindow INTEGER, cdx6500BRIX25ChanCfgPktSeqCount INTEGER, cdx6500BRIX25ChanCfgBWPktWindow INTEGER, cdx6500BRIX25ChanCfgBPPktSize INTEGER, cdx6500BRIX25ChanCfgMaxNegoPktSize INTEGER, cdx6500BRIX25ChanCfgDataQUpperThres INTEGER, cdx6500BRIX25ChanCfgDataQLowerThres INTEGER, cdx6500BRIX25ChanCfgRestartTimer INTEGER, cdx6500BRIX25ChanCfgResetTimer INTEGER, cdx6500BRIX25ChanCfgCallTimer INTEGER, cdx6500BRIX25ChanCfgClearTimer INTEGER, cdx6500BRIX25ChanCfgFacToDelFromOutbCalls DisplayString, cdx6500BRIX25ChanCfgFacToAddToOutbCalls DisplayString, cdx6500BRIX25ChanCfgFacToBarInOutbCalls DisplayString, cdx6500BRIX25ChanCfgFacToBarInInbCalls DisplayString, cdx6500BRIX25ChanCfgX25Options DisplayString, cdx6500BRIX25ChanCfgNumRoutDgtInCallUsrData INTEGER, cdx6500BRIX25ChanCfgNumPreAddrDgstrpOutgCalls INTEGER, cdx6500BRIX25ChanCfgInDigitsToStrip INTEGER, cdx6500BRIX25ChanCfgRestrictedConnDest DisplayString, cdx6500BRIX25ChanCfgPortAddress DisplayString, cdx6500BRIX25ChanCfgCUGMembership DisplayString, cdx6500BRIX25ChanCfgBillingRecords INTEGER, cdx6500BRIX25ChanCfgSubAddrSize INTEGER, cdx6500BRIX25ChanCfgCallSecurity INTEGER, cdx6500BRIX25ChanCfgProtectionLevel INTEGER, cdx6500BRIX25ChanCfgReconnTimeout INTEGER, cdx6500BRIX25ChanCfgReconnTriesLt INTEGER, cdx6500BRIX25ChanCfgFacSubsCtl DisplayString, cdx6500BRIX25ChanCfgAlarmPriority INTEGER, cdx6500BRIX25ChanCfgChanTEI INTEGER, cdx6500BRIX25ChanCfgX25NetworkType INTEGER, cdx6500BRIX25ChanCfgDNumSVCChannels INTEGER, cdx6500BRIX25ChanCfgDWPktWindow INTEGER, cdx6500BRIX25ChanCfgDPPktSize INTEGER, cdx6500BRIX25ChanCfgDKFrameWindow INTEGER, cdx6500BRIX25ChanCfgDN2TransTries INTEGER, cdx6500BRIX25ChanCfgT1Timer INTEGER, cdx6500BRIX25ChanCfgT2Timer INTEGER, cdx6500BRIX25ChanCfgLinkType INTEGER, cdx6500BRIX25ChanCfgAddrTrans DisplayString } cdx6500BRIX25ChanCfgPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The BRI port number." ::= { cdx6500PPCTBRIX25ChanEntry 1 } cdx6500BRIX25ChanCfgChannelNum OBJECT-TYPE SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION "Configured ISDN Channel Number." ::= { cdx6500PPCTBRIX25ChanEntry 2 } cdx6500BRIX25ChanCfgChannelType OBJECT-TYPE SYNTAX INTEGER { bChannel (3), dChannel (4) } ACCESS read-only STATUS mandatory DESCRIPTION "ISDN channel type. bChannel - a full duplex, 56 or 64 Kbps channel. dChannel - a full duplex, 16 Kbps channel configured only for packet mode." ::= { cdx6500PPCTBRIX25ChanEntry 3 } cdx6500BRIX25ChanCfgAccessType OBJECT-TYPE SYNTAX INTEGER { permanent (1), switched (2) } ACCESS read-only STATUS mandatory DESCRIPTION "permanent : Permanent BRI channels switched : Switched BRI channels." ::= { cdx6500PPCTBRIX25ChanEntry 4 } cdx6500BRIX25ChanCfgTimeslot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Physical channel number for permanent switch type only." ::= { cdx6500PPCTBRIX25ChanEntry 5 } cdx6500BRIX25ChanCfgSPID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..21)) ACCESS read-only STATUS mandatory DESCRIPTION "Service Profile Identifiers (SPID) is to define the services subscribed to by the ISDN device that is accessing the ISDN provider. This value is provided by your service provider." ::= { cdx6500PPCTBRIX25ChanEntry 6 } cdx6500BRIX25ChanCfgISDNCallAcc OBJECT-TYPE SYNTAX INTEGER { allCalls (2), addressOnly (3), addressSubaddress (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the ISDN routing for a setup message coming from the network. allCalls : ISDN routing for all setup message coming from the network. addressOnly : ISDN routing for specified address only. addressSubaddress : ISDN routing for specified subaddress only. " ::= { cdx6500PPCTBRIX25ChanEntry 7 } cdx6500BRIX25ChanCfgLocalSubsAddr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..36)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the local subscriber address which is provided by the service provider." ::= { cdx6500PPCTBRIX25ChanEntry 8 } cdx6500BRIX25ChanCfgLocalSubsSubAddr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the local subscriber subaddress which is provided by the service provider." ::= { cdx6500PPCTBRIX25ChanEntry 9 } cdx6500BRIX25ChanCfgRateAdaption OBJECT-TYPE SYNTAX INTEGER { rate56k (1), rate64k (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Rate adaption parameter for this channel. rate56k : Rate of 56 K rate64k : Rate of 64 K. " ::= { cdx6500PPCTBRIX25ChanEntry 10 } cdx6500BRIX25ChanCfgProtocolType OBJECT-TYPE SYNTAX INTEGER { x25 (2), fri (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the protocol type run over ISDN B channel." ::= { cdx6500PPCTBRIX25ChanEntry 11 } cdx6500BRIX25ChanCfgLinkAddr OBJECT-TYPE SYNTAX INTEGER { dte (1), dce (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The logical link address must be set to complementary values in devices at each end of the link: dte - link to have logical DTE address (A) dce - link to have logical DCE address (B)" ::= { cdx6500PPCTBRIX25ChanEntry 12 } cdx6500BRIX25ChanCfgNumPVCChannels OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-only STATUS mandatory DESCRIPTION "Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table." ::= { cdx6500PPCTBRIX25ChanEntry 13 } cdx6500BRIX25ChanCfgStartPVCChanNum OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-only STATUS mandatory DESCRIPTION "This is the starting logical channel number for the Permanent Virtual Circuits on this link. Not used if the number of PVCs = 0." ::= { cdx6500PPCTBRIX25ChanEntry 14 } cdx6500BRIX25ChanCfgBNumSVCChannels OBJECT-TYPE SYNTAX INTEGER (0..512) ACCESS read-only STATUS mandatory DESCRIPTION "Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. This is a B-channel object. " ::= { cdx6500PPCTBRIX25ChanEntry 15 } cdx6500BRIX25ChanCfgStartSVCChanNum OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "This is the starting logical channel number for the Switched Virtual Circuits on this link. Not used if the number of SVCs = 0." ::= { cdx6500PPCTBRIX25ChanEntry 16 } cdx6500BRIX25ChanCfgInitialFrame OBJECT-TYPE SYNTAX INTEGER { sabm (1), disc (2), none (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the initial frame required by other end for link startup: none - do nothing (other end initiates link-up) sabm - send SABM disc - send DISC, then SABM" ::= { cdx6500PPCTBRIX25ChanEntry 17 } cdx6500BRIX25ChanCfgT1TransRetryTimer OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "T1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds)." ::= { cdx6500PPCTBRIX25ChanEntry 18 } cdx6500BRIX25ChanCfgT4PollTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This sets the time an idle link is probed for assurance of connection to the remote device. 0 - disable the timer X - X is in tenths of a second (e.g. 40 = 4.0 seconds) and must be set greater than T1." ::= { cdx6500PPCTBRIX25ChanEntry 19 } cdx6500BRIX25ChanCfgBN2TransTries OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of attempts allowed to complete a transmission. This is a B channel object" ::= { cdx6500PPCTBRIX25ChanEntry 20 } cdx6500BRIX25ChanCfgFrameSeqCount OBJECT-TYPE SYNTAX INTEGER { norm (1), ext (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Port uses normal or extended frame sequence numbering: norm - normal sequencing (modulo 8) ext - extended sequencing (modulo 128)" ::= { cdx6500PPCTBRIX25ChanEntry 21 } cdx6500BRIX25ChanCfgBKFrameWindow OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Frame level window size must be set to the same value in devices at each end of the link. This is a B-channel object." ::= { cdx6500PPCTBRIX25ChanEntry 22 } cdx6500BRIX25ChanCfgPktSeqCount OBJECT-TYPE SYNTAX INTEGER { norm (1), ext (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Port uses normal or extended packet level sequence numbers norm - normal sequencing (Modulo 8) ext - extended sequencing (Modulo 128) The value must be the same in devices at each end of the link." ::= { cdx6500PPCTBRIX25ChanEntry 23 } cdx6500BRIX25ChanCfgBWPktWindow OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Packet level window size must be set to the same value in devices at each end of the link. This is a B-channel object." ::= { cdx6500PPCTBRIX25ChanEntry 24 } cdx6500BRIX25ChanCfgBPPktSize OBJECT-TYPE SYNTAX INTEGER { s128 (8), s256 (9), s512 (10), s1024 (11) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the maximum packet size used on X.25 links. For proper operation, the size must be the same in devices at each end of the link. This is a B-channel object." ::= { cdx6500PPCTBRIX25ChanEntry 25 } cdx6500BRIX25ChanCfgMaxNegoPktSize OBJECT-TYPE SYNTAX INTEGER { s128 (8), s256 (9), s512 (10), s1024 (11) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the maximum negotiated packet size allowed for inbound and outbound calls on this X.25 link." ::= { cdx6500PPCTBRIX25ChanEntry 26 } cdx6500BRIX25ChanCfgDataQUpperThres OBJECT-TYPE SYNTAX INTEGER (5..15) ACCESS read-only STATUS mandatory DESCRIPTION "This is the maximum number of data packets a channel on this port will queue for transmission before invoking flow control to the attached channel." ::= { cdx6500PPCTBRIX25ChanEntry 27 } cdx6500BRIX25ChanCfgDataQLowerThres OBJECT-TYPE SYNTAX INTEGER (0..4) ACCESS read-only STATUS mandatory DESCRIPTION "This is the number of data packets a channel on this port will have queued for transmission when it releases flow control to the attached channel." ::= { cdx6500PPCTBRIX25ChanEntry 28 } cdx6500BRIX25ChanCfgRestartTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-only STATUS mandatory DESCRIPTION "Restart-Request timeout timer in seconds. If timer expires, request is sent again." ::= { cdx6500PPCTBRIX25ChanEntry 29 } cdx6500BRIX25ChanCfgResetTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-only STATUS mandatory DESCRIPTION "Reset-Request timeout timer in seconds. If timer expires, request is sent again." ::= { cdx6500PPCTBRIX25ChanEntry 30 } cdx6500BRIX25ChanCfgCallTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-only STATUS mandatory DESCRIPTION "Call-Request timeout timer in seconds. If timer expires, call is cleared." ::= { cdx6500PPCTBRIX25ChanEntry 31 } cdx6500BRIX25ChanCfgClearTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-only STATUS mandatory DESCRIPTION "Clear-Request timeout timer in seconds. If timer expires, request is sent again." ::= { cdx6500PPCTBRIX25ChanEntry 32 } cdx6500BRIX25ChanCfgFacToDelFromOutbCalls OBJECT-TYPE SYNTAX DisplayString (SIZE(3..17)) ACCESS read-only STATUS mandatory DESCRIPTION "Specify facilities deleted from an outbound call before it is forwarded: NONE - no facilities deleted THRO - delete throughput class negotiation NUI - delete network user identification CUG - delete closed user group Any combination of above specified by summing (e.g. THRO+NUI. . .)." ::= { cdx6500PPCTBRIX25ChanEntry 33 } cdx6500BRIX25ChanCfgFacToAddToOutbCalls OBJECT-TYPE SYNTAX DisplayString (SIZE(3..18)) ACCESS read-only STATUS mandatory DESCRIPTION "Specify facilities added to an outbound call before it is forwarded: NONE - no facilities added REV - add reverse charging PACK - add packet size negotiation WIND - add window size negotiation Any combination of above specified by summing (e.g. PACK+WIND+. . .)." ::= { cdx6500PPCTBRIX25ChanEntry 34 } cdx6500BRIX25ChanCfgFacToBarInOutbCalls OBJECT-TYPE SYNTAX DisplayString (SIZE(3..24)) ACCESS read-only STATUS mandatory DESCRIPTION "Specify facilities which, if present in an outbound call, will be blocked by the port: NONE - no facility blocked REV - bar reverse charging FAST - bar fast select BCUG - bar Bilateral Closed User Group DGRAM - bar datagram Any combination of above specified by summing (e.g. REV+FAST)." ::= { cdx6500PPCTBRIX25ChanEntry 35 } cdx6500BRIX25ChanCfgFacToBarInInbCalls OBJECT-TYPE SYNTAX DisplayString (SIZE(3..19)) ACCESS read-only STATUS mandatory DESCRIPTION "Specify facilities which, if present in an inbound call, will be blocked by the port: NONE - no facility blocked BCUG - bar Bilateral Closed User Group DGRAM - bar datagram REV - bar Reverse Charging Any combination of above specified by summing (e.g. DGRAM+BCUG)." ::= { cdx6500PPCTBRIX25ChanEntry 36 } cdx6500BRIX25ChanCfgX25Options OBJECT-TYPE SYNTAX DisplayString (SIZE(3..107)) ACCESS read-only STATUS mandatory DESCRIPTION "Select X.25 options as follows: NONE - no option specified 1980 - use X.25 1980 NUI - perform network user identification validation check PDN - connected to Public Data Network CUD - use call user data subaddressing IBAR - bar all calls coming in from X.25 port user OBAR - bar all calls going out to X.25 port user CBCK - allow routing inbound calls back out this port CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart NRST - do not send restart packet on link-up BKUP - this is a backup port to be activated if other ports are down INL - inter-node link. Link goes to another 6500 device INLA - set with INL option when an X.25 link connection is to a 6500 node using 2.12.04 or earlier DELAY - Enable Delay and Path Trace on this link (link must be connected to Rel. 4.xx node) Any combination of above specified by summing (e.g. 1980+NUI+. . .)." ::= { cdx6500PPCTBRIX25ChanEntry 37 } cdx6500BRIX25ChanCfgNumRoutDgtInCallUsrData OBJECT-TYPE SYNTAX INTEGER (0..12) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of routing digits in the call user data. It is used on X.25 links attached to a Public Data Network where the private network address is carried in the call user data." ::= { cdx6500PPCTBRIX25ChanEntry 38 } cdx6500BRIX25ChanCfgNumPreAddrDgstrpOutgCalls OBJECT-TYPE SYNTAX INTEGER (0..14) ACCESS read-only STATUS mandatory DESCRIPTION "For X.25 links connected to a Public Data Network, this parameter specifies the number of prefix digits to remove from the called address before forwarding the call to the PDN." ::= { cdx6500PPCTBRIX25ChanEntry 39 } cdx6500BRIX25ChanCfgInDigitsToStrip OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "For X.25 links connected to a Public Data Network, this parameter specifies the number of prefix digits to remove from the incoming calling address before forwarding the call from the PDN." ::= { cdx6500PPCTBRIX25ChanEntry 40 } cdx6500BRIX25ChanCfgRestrictedConnDest OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "All calls entering this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route all calls to X.25 port 3, use X25-3. To route calls to SDLC port 2, station 4, use SDLC-2S4. Function is disabled for blank field." ::= { cdx6500PPCTBRIX25ChanEntry 41 } cdx6500BRIX25ChanCfgPortAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "On X.25 links: If the X.25 Option REGO, REGSO or REGI is selected, this address is inserted into the calling address field of the outbound or inbound call packet. On MUX links: When a MUX channel makes a call, the subaddress of the channel is appended to this address and inserted into the calling address field of the call packet." ::= { cdx6500PPCTBRIX25ChanEntry 42 } cdx6500BRIX25ChanCfgCUGMembership OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) ACCESS read-only STATUS mandatory DESCRIPTION "The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except double dash) and separated by a comma. ( e.g. 12,34,56,09,02,03 ). -- - No CUG Membership 00-99 - CUG Membership" ::= { cdx6500PPCTBRIX25ChanEntry 43 } cdx6500BRIX25ChanCfgBillingRecords OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This controls whether billing (accounting) records will be created for calls on this port." ::= { cdx6500PPCTBRIX25ChanEntry 44 } cdx6500BRIX25ChanCfgSubAddrSize OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-only STATUS mandatory DESCRIPTION "For ports connected to a Public Data Network, this parameter specifies the number of digits in the subaddress of an X.25 address." ::= { cdx6500PPCTBRIX25ChanEntry 45 } cdx6500BRIX25ChanCfgCallSecurity OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-only STATUS mandatory DESCRIPTION "For ports used as V.25 bis or SW56K backup, this parameter specifies the type of call security to use prior to the link being detected up. disable - Disable will allow both incoming and outgoing calls. enable - Enable will allow ONLY outgoing calls. Incoming calls will be immediately terminated." ::= { cdx6500PPCTBRIX25ChanEntry 46 } cdx6500BRIX25ChanCfgProtectionLevel OBJECT-TYPE SYNTAX INTEGER { none (1), cpOnly (2), fullDcp (3) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the level of data or connection protection which will be applied to calls to or from this port. The actual level for a call will be negotiated to the lesser of this level and the level configured for the other end of the call. none - No protection cpOnly - Connection protection only fullDcp - Full data and connection protection" ::= { cdx6500PPCTBRIX25ChanEntry 47 } cdx6500BRIX25ChanCfgReconnTimeout OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of seconds that DCP on the originating side will wait between reconnection attempts." ::= { cdx6500PPCTBRIX25ChanEntry 48 } cdx6500BRIX25ChanCfgReconnTriesLt OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of times that DCP on the originating side will attempt to reconnect before clearing the call. For0, it will not attempt to reconnect." ::= { cdx6500PPCTBRIX25ChanEntry 49 } cdx6500BRIX25ChanCfgFacSubsCtl OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "NONE - Subscription to facilities not enforced. FCN_ON - Flow Control Negotiation enabled. Packet and Window size negotiation facilities in an inbound call will be allowed. Packet and Window size facilities will always be included in outbound calls and call accepted/ connected when this parameter is set. FCN_OFF - Flow Control Negotiation disabled. Inbound calls containing Packet and Window size facilities will be cleared. Packet and Window size facilities will not be present in outbound calls and call accepted/connected when this parameter is set. TCN_ON - Throughput Class Negotiation enabled. The throughput class negotiation facility in an inbound call will be allowed. The throughput class negotiation facility will always be included in outbound calls and call accepted/connected when this parameter is set. The facility is passed onward to the destination in the call packet transparently and does not alter the handling of the SVC data within the node. TCN_OFF - Throughput Class Negotiation disabled. Inbound calls containing the throughput class negotiation facility will be cleared. The throughput class negotiation facility will not be present in outbound calls and call accepted/connected when this parameter is set. Some combinations of above options are allowed (e.g. FCNON+TCNON)" ::= { cdx6500PPCTBRIX25ChanEntry 50 } cdx6500BRIX25ChanCfgAlarmPriority OBJECT-TYPE SYNTAX INTEGER { network (1), access (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the severity level of LINK UP and LINK DOWN alarms: network - Severity HIGH alarms will be generated access - Severity LOW alarms will be generated" ::= { cdx6500PPCTBRIX25ChanEntry 51 } cdx6500BRIX25ChanCfgChanTEI OBJECT-TYPE SYNTAX INTEGER (1..63) ACCESS read-only STATUS mandatory DESCRIPTION "Terminal Endpoint Identifier. Value is provided by the service provider." ::= { cdx6500PPCTBRIX25ChanEntry 52 } cdx6500BRIX25ChanCfgX25NetworkType OBJECT-TYPE SYNTAX INTEGER { transpac (1), telenet (2), pss (3), datanet (4) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the X.25 Network Type: Transpac, PSS, Datanet, Telenet." ::= { cdx6500PPCTBRIX25ChanEntry 53 } cdx6500BRIX25ChanCfgDNumSVCChannels OBJECT-TYPE SYNTAX INTEGER (1..15) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the number of logical SVC channels on this port. This is a D-channel object." ::= { cdx6500PPCTBRIX25ChanEntry 54 } cdx6500BRIX25ChanCfgDWPktWindow OBJECT-TYPE SYNTAX INTEGER (1..7) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the default packet level window size when it is not negotiated for the individual call. The value must be the same for both ends of the link. This is a D-channel object." ::= { cdx6500PPCTBRIX25ChanEntry 55 } cdx6500BRIX25ChanCfgDPPktSize OBJECT-TYPE SYNTAX INTEGER { psize32 (6), psize64 (7), psize128 (8), psize256 (9) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the maximum default packet size (in bytes) for inbound and outbound calls on the link. The value must be the same for both ends of the link. This is a D-channel object." ::= { cdx6500PPCTBRIX25ChanEntry 56 } cdx6500BRIX25ChanCfgDKFrameWindow OBJECT-TYPE SYNTAX INTEGER (1..7) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the number of unacknowledged frames that can be outstanding. When there is a high link delay, set this parameter to a high value to improve throughput. The setting for this parameter should be the same for the devices on both ends of the link. This is a D-channel object." ::= { cdx6500PPCTBRIX25ChanEntry 57 } cdx6500BRIX25ChanCfgDN2TransTries OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the maximum number of times a frame is resent before disconnect. This is a D-channel object." ::= { cdx6500PPCTBRIX25ChanEntry 58 } cdx6500BRIX25ChanCfgT1Timer OBJECT-TYPE SYNTAX INTEGER (0..16383) ACCESS read-only STATUS mandatory DESCRIPTION "Sets the T1 Retry Timer. The values are in tenths of a second. (30 = 3.0 seconds)" ::= { cdx6500PPCTBRIX25ChanEntry 59 } cdx6500BRIX25ChanCfgT2Timer OBJECT-TYPE SYNTAX INTEGER (0..16383) ACCESS read-only STATUS mandatory DESCRIPTION "Sets the T2 timer. The values are in tenths of a second. (40 = 4.0 seconds)" ::= { cdx6500PPCTBRIX25ChanEntry 60 } cdx6500BRIX25ChanCfgLinkType OBJECT-TYPE SYNTAX INTEGER { dChannel (1), v24Dte (2), v24Dce (3) } ACCESS read-only STATUS mandatory DESCRIPTION "Engineering use only. Sets the link type: dChannel - Run over the D channel v24Dte - DTE on the V.24 port v24Dce - DCE on the V.24 port" ::= { cdx6500PPCTBRIX25ChanEntry 61 } cdx6500BRIX25ChanCfgAddrTrans OBJECT-TYPE SYNTAX DisplayString (SIZE(3..107)) ACCESS read-only STATUS mandatory DESCRIPTION "Select any of the following address translation options NONE - no option specified Outbound Call Processing: DEDO - delete called address DEGO - delete calling address REGO - replace calling address with configured Port Address REGSO - replace calling address with configured Port Address plus Inbound Subaddress obtained from the Inbound Call Translation Table entry where Private Network Address matches the entire calling address INGO - replace calling address with configured Port Address and retain original calling subaddress SAGO - strip calling address, but retain subaddress Inbound Call Processing: INGI - replace calling address with configured Port Address and retain original calling subaddress REGI - replace calling address with configured Port Address SRGI - select route from the Calling Address Translation Table by replacing the called address with the Private Network Address where the Inbound Calling Address matches the beginning of the calling address Call Accept Processing: DADA - delete called address in inbound/outbound call accept DAGA - delete calling address in inbound/outbound call accept IADD - copy called and calling addresses from call request into outbound call accepted/connected Some of the options may be combined (e.g. DEDO + DEGO)." ::= { cdx6500PPCTBRIX25ChanEntry 62 } cdx6500BRIStats OBJECT IDENTIFIER ::= { cdx6500PSTPortProtocolGroup 27 } cdx6500BRIPStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500BRIPStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of BRI port statistics." ::= {cdx6500BRIStats 1 } cdx6500BRIPStatsTableEntry OBJECT-TYPE SYNTAX Cdx6500BRIPStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the statistics for a single BRI port." INDEX { cdx6500BRIPStatPortNumber } ::= { cdx6500BRIPStatsTable 1 } Cdx6500BRIPStatsTableEntry ::= SEQUENCE { cdx6500BRIPStatPortNumber INTEGER, cdx6500BRIPStatPortType INTEGER, cdx6500BRIPStatPortStatus DisplayString, cdx6500BRIPStatNumConfigChannels INTEGER, cdx6500BRIPStatSwitchType DisplayString, cdx6500BRIPStatTEI INTEGER, cdx6500BRIPStatLastStatsReset DisplayString, cdx6500BRIPStatCharsInTot Counter, cdx6500BRIPStatCharsInPerSec INTEGER, cdx6500BRIPStatCharsOutTot Counter, cdx6500BRIPStatCharsOutPerSec INTEGER, cdx6500BRIPStatFramesInTot Counter, cdx6500BRIPStatFramesInPerSec INTEGER, cdx6500BRIPStatFrameOutTot Counter, cdx6500BRIPStatFrameOutPerSec INTEGER, cdx6500BRIPStatAvFrameSzIn INTEGER, cdx6500BRIPStatAvFrameSzOut INTEGER, cdx6500BRIPStatPortUtilIn INTEGER, cdx6500BRIPStatPortUtilOut INTEGER, cdx6500BRIPStatPortUtilInMax INTEGER, cdx6500BRIPStatPortUtilOutMax INTEGER } cdx6500BRIPStatPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the BRI port." ::= { cdx6500BRIPStatsTableEntry 1 } cdx6500BRIPStatPortType OBJECT-TYPE SYNTAX INTEGER { bri (40) } ACCESS read-only STATUS mandatory DESCRIPTION "The Port Type of the port." ::= { cdx6500BRIPStatsTableEntry 2 } cdx6500BRIPStatPortStatus OBJECT-TYPE SYNTAX DisplayString (SIZE(2..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Status of this port : Enabled - Port is enabled Disabled - Port is disabled Busyout - Port has been busied out Unknown - Port not recognized Init Failed - Port initialization failed." ::= { cdx6500BRIPStatsTableEntry 3 } cdx6500BRIPStatNumConfigChannels OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-only STATUS mandatory DESCRIPTION "The number of configured channels." ::= { cdx6500BRIPStatsTableEntry 4 } cdx6500BRIPStatSwitchType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..23)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies switch type for the central office. VN4 : French VN4 standard 1TR6 : German switch standard BTNR : UK Standard ETSI : Euro-ISDN 5ESS : AT&T switch NI-1 : National ISDN version 1 " ::= { cdx6500BRIPStatsTableEntry 5 } cdx6500BRIPStatTEI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Terminal Endpoint Identifier. The range of values [0 - 63] indicate a static TEI provided by the Network subscribing. 127: TEI negotiated" ::= { cdx6500BRIPStatsTableEntry 6 } cdx6500BRIPStatLastStatsReset OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time when the statistics were last reset." ::= { cdx6500BRIPStatsTableEntry 7 } cdx6500BRIPStatCharsInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received since last node, port or statistics reset." ::= { cdx6500BRIPStatsTableEntry 8 } cdx6500BRIPStatCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters received per second since last node, port or statistics reset." ::= { cdx6500BRIPStatsTableEntry 9 } cdx6500BRIPStatCharsOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters sent since last node, port or statistics reset." ::= { cdx6500BRIPStatsTableEntry 10 } cdx6500BRIPStatCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters sent per second since last node, port or statistics reset." ::= { cdx6500BRIPStatsTableEntry 11 } cdx6500BRIPStatFramesInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received since last node, port or statistics reset." ::= { cdx6500BRIPStatsTableEntry 12 } cdx6500BRIPStatFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of Frames received per second since last node, port or statistics reset." ::= { cdx6500BRIPStatsTableEntry 13 } cdx6500BRIPStatFrameOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent since last node, port or statistics reset." ::= { cdx6500BRIPStatsTableEntry 14 } cdx6500BRIPStatFrameOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of Frames sent per second since last node, port or statistics reset." ::= { cdx6500BRIPStatsTableEntry 15 } cdx6500BRIPStatAvFrameSzIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average size of the frames received." ::= { cdx6500BRIPStatsTableEntry 16 } cdx6500BRIPStatAvFrameSzOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average size of the frames sent." ::= { cdx6500BRIPStatsTableEntry 17 } cdx6500BRIPStatPortUtilIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current inbound port utilization." ::= { cdx6500BRIPStatsTableEntry 18 } cdx6500BRIPStatPortUtilOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current outbound port utilization." ::= { cdx6500BRIPStatsTableEntry 19 } cdx6500BRIPStatPortUtilInMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum inbound port utilization." ::= { cdx6500BRIPStatsTableEntry 20 } cdx6500BRIPStatPortUtilOutMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum outbound port utilization." ::= { cdx6500BRIPStatsTableEntry 21 } cdx6500BRIChanStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500BRIChanStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of BRI channel statistics." ::= { cdx6500BRIStats 2 } cdx6500BRIChanStatsTableEntry OBJECT-TYPE SYNTAX Cdx6500BRIChanStatsTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry contains the statistics for a single channel." INDEX { cdx6500BRICStatsPortNumber, cdx6500BRICStatsChannelNum } ::= { cdx6500BRIChanStatsTable 1 } Cdx6500BRIChanStatsTableEntry ::= SEQUENCE { cdx6500BRICStatsPortNumber INTEGER, cdx6500BRICStatsChannelNum INTEGER, cdx6500BRICStatsChannelType DisplayString, cdx6500BRICStatsAccessType DisplayString, cdx6500BRICStatsProtocolType DisplayString, cdx6500BRICStatsCallState DisplayString, cdx6500BRICStatsChannelStatus DisplayString, cdx6500BRICStatsInCurCallAddr DisplayString, cdx6500BRICStatsInCurCallSubAddr DisplayString, cdx6500BRICStatsInAvConnTm DisplayString, cdx6500BRICStatsInCurConnTm DisplayString, cdx6500BRICStatsInMinConnTm DisplayString, cdx6500BRICStatsInMaxConnTm DisplayString, cdx6500BRICStatsInNumSuccCalls INTEGER, cdx6500BRICStatsInNumFailCalls INTEGER, cdx6500BRICStatsOutCurCallAddr DisplayString, cdx6500BRICStatsOutCurCallSubAddr DisplayString, cdx6500BRICStatsOutAvConnTm DisplayString, cdx6500BRICStatsOutCurConnTm DisplayString, cdx6500BRICStatsOutMinConnTm DisplayString, cdx6500BRICStatsOutMaxConnTm DisplayString, cdx6500BRICStatsOutNumSuccCalls INTEGER, cdx6500BRICStatsOutNumFailCalls INTEGER, cdx6500BRICStatsMaxSVC INTEGER, cdx6500BRICStatsMaxPVC INTEGER, cdx6500BRICStatsCurSVC INTEGER, cdx6500BRICStatsCurPVC INTEGER, cdx6500BRICStatsLastRepReasonCodes DisplayString, cdx6500BRICStatsLastStatsReset DisplayString, cdx6500BRICStatsCharsInTot Counter, cdx6500BRICStatsCharsOutTot Counter, cdx6500BRICStatsCharsInPerSec INTEGER, cdx6500BRICStatsCharsOutPerSec INTEGER, cdx6500BRICStatsPktsInTot Counter, cdx6500BRICStatsPktsOutTot Counter, cdx6500BRICStatsPktsInPerSec INTEGER, cdx6500BRICStatsPktsOutPerSec INTEGER, cdx6500BRICStatsFramesInTot Counter, cdx6500BRICStatsFramesOutTot Counter, cdx6500BRICStatsFramesInPerSec INTEGER, cdx6500BRICStatsFramesOutPerSec INTEGER, cdx6500BRICStatsInfoFramesIn Counter, cdx6500BRICStatsInfoFramesOut Counter, cdx6500BRICStatsRNRFramesIn Counter, cdx6500BRICStatsRNRFramesOut Counter, cdx6500BRICStatsSABMFramesIn Counter, cdx6500BRICStatsSABMFramesOut Counter, cdx6500BRICStatsDMFramesIn Counter, cdx6500BRICStatsDMFramesOut Counter, cdx6500BRICStatsRRFramesIn Counter, cdx6500BRICStatsRRFramesOut Counter, cdx6500BRICStatsREJFramesIn Counter, cdx6500BRICStatsREJFramesOut Counter, cdx6500BRICStatsDISCFramesIn Counter, cdx6500BRICStatsDISCFramesOut Counter, cdx6500BRICStatsUAFramesIn Counter, cdx6500BRICStatsUAFramesOut Counter, cdx6500BRICStatsFRMRFramesIn Counter, cdx6500BRICStatsFRMRFramesOut Counter, cdx6500BRICStatsDataPktsIn Counter, cdx6500BRICStatsDataPktsOut Counter, cdx6500BRICStatsRRPktsIn Counter, cdx6500BRICStatsRRPktsOut Counter, cdx6500BRICStatsRNRPktsIn Counter, cdx6500BRICStatsRNRPktsOut Counter, cdx6500BRICStatsRejPktsIn Counter, cdx6500BRICStatsRejPktsOut Counter, cdx6500BRICStatsCallReqPktsIn Counter, cdx6500BRICStatsCallReqPktsOut Counter, cdx6500BRICStatsCallAccPktsIn Counter, cdx6500BRICStatsCallAccPktsOut Counter, cdx6500BRICStatsClrReqPktsIn Counter, cdx6500BRICStatsClrReqPktsOut Counter, cdx6500BRICStatsClrConfPktsIn Counter, cdx6500BRICStatsClrConfPktsOut Counter, cdx6500BRICStatsIntReqPktsIn Counter, cdx6500BRICStatsIntReqPktsOut Counter, cdx6500BRICStatsIntConfPktsIn Counter, cdx6500BRICStatsIntConfPktsOut Counter, cdx6500BRICStatsRstReqPktsIn Counter, cdx6500BRICStatsRstReqPktsOut Counter, cdx6500BRICStatsRstConfPktsIn Counter, cdx6500BRICStatsRstConfPktsOut Counter, cdx6500BRICStatsRestartReqPktsIn Counter, cdx6500BRICStatsRestartReqPktsOut Counter, cdx6500BRICStatsRestartConfPktsIn Counter, cdx6500BRICStatsRestartConfPktsOut Counter, cdx6500BRICStatsTEI INTEGER, cdx6500BRICStatsSAPI INTEGER, cdx6500BRICStatsNetworkType DisplayString } cdx6500BRICStatsPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The BRI port number associated with the channels." ::= { cdx6500BRIChanStatsTableEntry 1 } cdx6500BRICStatsChannelNum OBJECT-TYPE SYNTAX INTEGER (1..3) ACCESS read-only STATUS mandatory DESCRIPTION "The ISDN channel Number." ::= { cdx6500BRIChanStatsTableEntry 2 } cdx6500BRICStatsChannelType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "ISDN channel type. B Channel : a full duplex, 56 or 64 Kbps channel. D Channel : a full duplex, 16 Kbps channel configured only for packet mode. Unknown : unknown channel type ." ::= { cdx6500BRIChanStatsTableEntry 3 } cdx6500BRICStatsAccessType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Switched BRI channel type. Permanent channel type : not supported in this version Unknown : unknown access type ." ::= { cdx6500BRIChanStatsTableEntry 4 } cdx6500BRICStatsProtocolType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the protocol type such as X25, FRI. `Unknown' indicates unknown protocol type." ::= { cdx6500BRIChanStatsTableEntry 5 } cdx6500BRICStatsCallState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Call State: Disconnected - Call in Idle state Ringing - Trying to establish connection Connected - Call connected Disabled - Call disabled Congested - not supported Unknown - unknown state ." ::= { cdx6500BRIChanStatsTableEntry 6 } cdx6500BRICStatsChannelStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Disabled - Channel disabled. Enabled - Channel enabled. Busyout - Channel busyout Unknown - unknown status." ::= { cdx6500BRIChanStatsTableEntry 7 } cdx6500BRICStatsInCurCallAddr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The address for the current inbound ISDN call." ::= { cdx6500BRIChanStatsTableEntry 8 } cdx6500BRICStatsInCurCallSubAddr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The subaddress for the current ISDN call." ::= { cdx6500BRIChanStatsTableEntry 9 } cdx6500BRICStatsInAvConnTm OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Average connection time for an inbound ISDN call." ::= { cdx6500BRIChanStatsTableEntry 10 } cdx6500BRICStatsInCurConnTm OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Current connection time for an inbound ISDN call. current time - Time connection started." ::= { cdx6500BRIChanStatsTableEntry 11 } cdx6500BRICStatsInMinConnTm OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Minimum connection time for an inbound ISDN call." ::= { cdx6500BRIChanStatsTableEntry 12 } cdx6500BRICStatsInMaxConnTm OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Maximum connection time for an inbound ISDN call." ::= { cdx6500BRIChanStatsTableEntry 13 } cdx6500BRICStatsInNumSuccCalls OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of successful inbound calls." ::= { cdx6500BRIChanStatsTableEntry 14 } cdx6500BRICStatsInNumFailCalls OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of unsuccessful inbound calls." ::= { cdx6500BRIChanStatsTableEntry 15 } cdx6500BRICStatsOutCurCallAddr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The address of the current ISDN outbound call." ::= { cdx6500BRIChanStatsTableEntry 16 } cdx6500BRICStatsOutCurCallSubAddr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The subaddress of the current ISDN outbound call." ::= { cdx6500BRIChanStatsTableEntry 17 } cdx6500BRICStatsOutAvConnTm OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Average connection time for an outbound call." ::= { cdx6500BRIChanStatsTableEntry 18 } cdx6500BRICStatsOutCurConnTm OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Current connection time for an outbound call. Current time - Time connection started." ::= { cdx6500BRIChanStatsTableEntry 19 } cdx6500BRICStatsOutMinConnTm OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Minimum connection time for an outbound call." ::= { cdx6500BRIChanStatsTableEntry 20 } cdx6500BRICStatsOutMaxConnTm OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Maximum connection time for an outbound call." ::= { cdx6500BRIChanStatsTableEntry 21 } cdx6500BRICStatsOutNumSuccCalls OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of successful outbound calls." ::= { cdx6500BRIChanStatsTableEntry 22 } cdx6500BRICStatsOutNumFailCalls OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of unsuccessful outbound calls." ::= { cdx6500BRIChanStatsTableEntry 23 } cdx6500BRICStatsMaxSVC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of async Switched Virtual Circuit channels." ::= { cdx6500BRIChanStatsTableEntry 24 } cdx6500BRICStatsMaxPVC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of async Permanent Virtual Circuit channels." ::= { cdx6500BRIChanStatsTableEntry 25 } cdx6500BRICStatsCurSVC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of async Switched Virtual Circuit channels." ::= { cdx6500BRIChanStatsTableEntry 26 } cdx6500BRICStatsCurPVC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of async Permament Virtual Circuit channels." ::= { cdx6500BRIChanStatsTableEntry 27 } cdx6500BRICStatsLastRepReasonCodes OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Last Reason codes returned from the network and Last Return code from Transparent." ::= { cdx6500BRIChanStatsTableEntry 28 } cdx6500BRICStatsLastStatsReset OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time when the node restarted or the stats reset by CTP command ." ::= { cdx6500BRIChanStatsTableEntry 29 } cdx6500BRICStatsCharsInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received." ::= { cdx6500BRIChanStatsTableEntry 30 } cdx6500BRICStatsCharsOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters sent." ::= { cdx6500BRIChanStatsTableEntry 31 } cdx6500BRICStatsCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters received per second." ::= { cdx6500BRIChanStatsTableEntry 32 } cdx6500BRICStatsCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters sent per second." ::= { cdx6500BRIChanStatsTableEntry 33 } cdx6500BRICStatsPktsInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets received." ::= { cdx6500BRIChanStatsTableEntry 34 } cdx6500BRICStatsPktsOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets sent." ::= { cdx6500BRIChanStatsTableEntry 35 } cdx6500BRICStatsPktsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of packets received per second." ::= { cdx6500BRIChanStatsTableEntry 36 } cdx6500BRICStatsPktsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of packets sent per second." ::= { cdx6500BRIChanStatsTableEntry 37 } cdx6500BRICStatsFramesInTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames received." ::= { cdx6500BRIChanStatsTableEntry 38 } cdx6500BRICStatsFramesOutTot OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames sent." ::= { cdx6500BRIChanStatsTableEntry 39 } cdx6500BRICStatsFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames received per second." ::= { cdx6500BRIChanStatsTableEntry 40 } cdx6500BRICStatsFramesOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames sent per second." ::= { cdx6500BRIChanStatsTableEntry 41 } cdx6500BRICStatsInfoFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Information frames received." ::= { cdx6500BRIChanStatsTableEntry 42 } cdx6500BRICStatsInfoFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Information frames sent." ::= { cdx6500BRIChanStatsTableEntry 43 } cdx6500BRICStatsRNRFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Receiver Not Ready (RNR) frames received." ::= { cdx6500BRIChanStatsTableEntry 44 } cdx6500BRICStatsRNRFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Receiver Not Ready (RNR) frames sent." ::= { cdx6500BRIChanStatsTableEntry 45 } cdx6500BRICStatsSABMFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Set Asynchronous Balanced Mode (SABM) frames received." ::= { cdx6500BRIChanStatsTableEntry 46 } cdx6500BRICStatsSABMFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Set Asynchronous Balanced Mode (SABM) frames sent." ::= { cdx6500BRIChanStatsTableEntry 47 } cdx6500BRICStatsDMFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Disconnect Mode (DM) frames received." ::= { cdx6500BRIChanStatsTableEntry 48 } cdx6500BRICStatsDMFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Disconnect Mode (DM) frames sent." ::= { cdx6500BRIChanStatsTableEntry 49 } cdx6500BRICStatsRRFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Receiver Ready (RR) frames received." ::= { cdx6500BRIChanStatsTableEntry 50 } cdx6500BRICStatsRRFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Receiver Ready (RR) frames sent." ::= { cdx6500BRIChanStatsTableEntry 51 } cdx6500BRICStatsREJFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Reject (REJ) frames received." ::= { cdx6500BRIChanStatsTableEntry 52 } cdx6500BRICStatsREJFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Reject (REJ) frames sent." ::= { cdx6500BRIChanStatsTableEntry 53 } cdx6500BRICStatsDISCFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Disconnect (DISC) frames received." ::= { cdx6500BRIChanStatsTableEntry 54 } cdx6500BRICStatsDISCFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Disconnect (DISC) frames sent." ::= { cdx6500BRIChanStatsTableEntry 55 } cdx6500BRICStatsUAFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Unnumbered Acknowledgement (UA) frames received." ::= { cdx6500BRIChanStatsTableEntry 56 } cdx6500BRICStatsUAFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Unnumbered Acknowledgement (UA) frames sent." ::= { cdx6500BRIChanStatsTableEntry 57 } cdx6500BRICStatsFRMRFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Frame Reject (FRMR) frames received." ::= { cdx6500BRIChanStatsTableEntry 58 } cdx6500BRICStatsFRMRFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Frame Reject (FRMR) frames sent." ::= { cdx6500BRIChanStatsTableEntry 59 } cdx6500BRICStatsDataPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Data packets received." ::= { cdx6500BRIChanStatsTableEntry 60 } cdx6500BRICStatsDataPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Data packets sent." ::= { cdx6500BRIChanStatsTableEntry 61 } cdx6500BRICStatsRRPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Receiver Ready (RR) packets received." ::= { cdx6500BRIChanStatsTableEntry 62 } cdx6500BRICStatsRRPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Receiver Ready (RR) packets sent." ::= { cdx6500BRIChanStatsTableEntry 63 } cdx6500BRICStatsRNRPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Receiver Not Ready (RNR) packets received." ::= { cdx6500BRIChanStatsTableEntry 64 } cdx6500BRICStatsRNRPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Receiver Not Ready (RNR) packets sent." ::= { cdx6500BRIChanStatsTableEntry 65 } cdx6500BRICStatsRejPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Reject packets received." ::= { cdx6500BRIChanStatsTableEntry 66 } cdx6500BRICStatsRejPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Reject packets sent." ::= { cdx6500BRIChanStatsTableEntry 67 } cdx6500BRICStatsCallReqPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Call Request packets received." ::= { cdx6500BRIChanStatsTableEntry 68 } cdx6500BRICStatsCallReqPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Call Request packets sent." ::= { cdx6500BRIChanStatsTableEntry 69 } cdx6500BRICStatsCallAccPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Call Accept packets received." ::= { cdx6500BRIChanStatsTableEntry 70 } cdx6500BRICStatsCallAccPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Call Acceptt packets sent." ::= { cdx6500BRIChanStatsTableEntry 71 } cdx6500BRICStatsClrReqPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Clear Request packets received." ::= { cdx6500BRIChanStatsTableEntry 72 } cdx6500BRICStatsClrReqPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Clear Request packets sent." ::= { cdx6500BRIChanStatsTableEntry 73 } cdx6500BRICStatsClrConfPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Clear Confirmation packets received." ::= { cdx6500BRIChanStatsTableEntry 74 } cdx6500BRICStatsClrConfPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Clear Confirmation packets sent." ::= { cdx6500BRIChanStatsTableEntry 75 } cdx6500BRICStatsIntReqPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Interrupt Request packets received." ::= { cdx6500BRIChanStatsTableEntry 76 } cdx6500BRICStatsIntReqPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Interrupt Request packets sent." ::= { cdx6500BRIChanStatsTableEntry 77 } cdx6500BRICStatsIntConfPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Interrupt Confirmation packets received." ::= { cdx6500BRIChanStatsTableEntry 78 } cdx6500BRICStatsIntConfPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Interrupt Confirmation packets sent." ::= { cdx6500BRIChanStatsTableEntry 79 } cdx6500BRICStatsRstReqPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Reset Request packets received." ::= { cdx6500BRIChanStatsTableEntry 80 } cdx6500BRICStatsRstReqPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Reset Request packets sent." ::= { cdx6500BRIChanStatsTableEntry 81 } cdx6500BRICStatsRstConfPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Reset Confirmation packets received." ::= { cdx6500BRIChanStatsTableEntry 82 } cdx6500BRICStatsRstConfPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Reset Confirmation packets sent." ::= { cdx6500BRIChanStatsTableEntry 83 } cdx6500BRICStatsRestartReqPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Restart Request packets received." ::= { cdx6500BRIChanStatsTableEntry 84 } cdx6500BRICStatsRestartReqPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Restart Request packets sent." ::= { cdx6500BRIChanStatsTableEntry 85 } cdx6500BRICStatsRestartConfPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Restart Confirmation packets received." ::= { cdx6500BRIChanStatsTableEntry 86 } cdx6500BRICStatsRestartConfPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total Number of Restart Confirmation packets sent." ::= { cdx6500BRIChanStatsTableEntry 87 } cdx6500BRICStatsTEI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Terminal Endpoint Identifier provided by the Network subscribing." ::= { cdx6500BRIChanStatsTableEntry 88 } cdx6500BRICStatsSAPI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Service Access Point Identifier. A value of 16 is reserved for Packet-mode communication on the D-channel using X.25 level 3." ::= { cdx6500BRIChanStatsTableEntry 89 } cdx6500BRICStatsNetworkType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the X.25 Network Type: Transpac, PSS, Datanet, Telenet, Unknown ." ::= { cdx6500BRIChanStatsTableEntry 90 } END