-- MIB file created 28-Oct-2010 15:02:34, by -- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com CISCO-6400-CHASSIS-MIB DEFINITIONS ::= BEGIN -- From file: "CISCO-6400-CHASSIS-MIB.my" -- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T" IMPORTS RowStatus, DisplayString FROM SNMPv2-TC-v1 ifIndex FROM IF-MIB ciscoExperiment FROM CISCO-SMI Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; cisco6400ChassisMIB OBJECT IDENTIFIER ::= { ciscoExperiment 27 } -- MODULE-IDENTITY -- LastUpdated -- 200110220000Z -- OrgName -- Cisco Systems, Inc. -- ContactInfo -- Cisco Systems -- Customer Service -- -- Postal: 170 W Tasman Drive -- San Jose, CA 95134 -- USA -- -- Tel: +1 800 553-NETS -- -- E-mail: cs-atm@cisco.com -- Descr -- Add nrpSwitchoverAlarm, -- nrpSecondaryFailureAlarm, -- nrpSecondaryRemovedAlarm, and -- nrpMismatchAlarm. -- RevDate -- 200110220000Z -- RevDescr -- Add nrpBootUpAlarm. Deprecated cisco6400ChassisMIBCompliance -- and cisco6400RedundantGroup. Created cisco6400ChassisMIBCompliance -- and cisco6400RedundantGroup2. -- RevDate -- 200105101234Z -- RevDescr -- Add diskAlarm and imageAlarm. -- RevDate -- 200009251234Z -- RevDescr -- 6400 Chassis MIB. -- RevDate -- 9903220000Z -- RevDescr -- Add Signal Fail BER. -- RevDate -- 9808050000Z -- RevDescr -- Update chassis alarm threshold setup range & main-cpu auto-sync -- flags. -- RevDate -- 9712100000Z -- RevDescr -- Initial version of this MIB module. cisco6400ChassisMIBObjects OBJECT IDENTIFIER ::= { cisco6400ChassisMIB 1 } c64RedundantGroup OBJECT IDENTIFIER ::= { cisco6400ChassisMIBObjects 1 } c64ChassisGroup OBJECT IDENTIFIER ::= { cisco6400ChassisMIBObjects 2 } c64TelcoAlarmMgmt OBJECT IDENTIFIER ::= { c64ChassisGroup 1 } cisco6400ChassisMIBNotificationPrefix OBJECT IDENTIFIER ::= { cisco6400ChassisMIB 2 } cisco6400ChassisMIBNotification OBJECT IDENTIFIER ::= { cisco6400ChassisMIBNotificationPrefix 0 } cisco6400ChassisMIBConformance OBJECT IDENTIFIER ::= { cisco6400ChassisMIB 3 } cisco6400ChassisMIBCompliances OBJECT IDENTIFIER ::= { cisco6400ChassisMIBConformance 1 } cisco6400ChassisMIBGroups OBJECT IDENTIFIER ::= { cisco6400ChassisMIBConformance 2 } APSEventStatus ::= INTEGER { good(1), noHardware(2), doNotRevert(3), manualSwitch(4), signgalDegrade(5), forceSwitch(6), lockOut(7), adminDown(8) } -- TEXTUAL-CONVENTION -- Status -- mandatory -- Descr -- APS event status of APS channel. c64MainCPUConfigAutoSync OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object is an OR bit mask indicating various auto-sync configuration: Bit 0, if set, indicates that standard syncable objects are set for auto-sync. The standard set of objects may evolve from software release to release. In release 1, this set is startup-config, bootvar and config-register. This flag is independent to the other flag settings described below. Bit 1, if set, indicates startup-config is set for auto-sync Bit 2. if set, indicates running-config is set for auto-sync. This flag is not supported in revison 1. Bit 3, if set, indicates bootvar is set for auto-sync Bit 4, if set, indicates config-register is set for auto-sync. Bit 5..31, are reserved for future expansion. Setting any bit in this range will have no effect." ::= { c64RedundantGroup 1 } c64MainCPUSwitchOver OBJECT-TYPE SYNTAX INTEGER { ok(1), forceOver(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object, when read always return a value of ok(1). Setting this object to forceOver(2) will have: For a redundant NSP-A|B, force them to exchange the primary and secondary roles. The primary NSP will be reloaded." ::= { c64RedundantGroup 2 } c64SlotConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF C64SlotConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of redundant slot-pair entries. A managment station that wish to create the redundancy entry other than NSP should perform the following steps: Get the ciscoLS1010ModuleIndex from ciscoLS1010ModuleTable which are mapped to the corresponding pair of the physical slots to be configured for redundancy. Use the pair of the ciscoLS1010ModuleIndex and a unique entry index to create table entry. Only the adjacent slots can be configured for redundancy." ::= { c64RedundantGroup 3 } c64SlotConfigEntry OBJECT-TYPE SYNTAX C64SlotConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry containing information for a particular pair of redundant slots. The object value of c64Slot1Index & c64Slot2Index refer to the pair of ciscoLS1010ModuleIndex in ciscoLS1010ModuleTable to be configured as redundant." INDEX { c64SlotConfigModule1Index, c64SlotConfigModule2Index } ::= { c64SlotConfigTable 1 } C64SlotConfigEntry ::= SEQUENCE { c64SlotConfigModule1Index INTEGER, c64SlotConfigModule2Index INTEGER, c64Slot1Name DisplayString, c64Slot2Name DisplayString, c64SlotConfigPrefIndex INTEGER, c64SlotSwitchOver INTEGER, c64SlotConfigStatus RowStatus } c64SlotConfigModule1Index OBJECT-TYPE SYNTAX INTEGER(1..15) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the first slot in the pair of slots to be configured for the redundacy. Its value is obtained from ciscoLS1010ModuleIndex in ciscoLS1010ModuleTable." ::= { c64SlotConfigEntry 1 } c64SlotConfigModule2Index OBJECT-TYPE SYNTAX INTEGER(1..15) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the second slot in the pair of slots to be configured for the redundacy. Its value is the obtained from ciscoLS1010ModuleIndex in ciscoLS1010ModuleTable." ::= { c64SlotConfigEntry 2 } c64Slot1Name OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of slot#1 in the pair of slots configured to redundant." ::= { c64SlotConfigEntry 3 } c64Slot2Name OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of slot#2 in the pair of slots configured to redundant." ::= { c64SlotConfigEntry 4 } c64SlotConfigPrefIndex OBJECT-TYPE SYNTAX INTEGER { primarySlot(1), secondarySlot(2) } ACCESS read-write STATUS deprecated DESCRIPTION "This object specify which slot in the pair of redundancy to be used as prefer slot. The value of: primarySlot(1) is telling the system use the slot referred by c64Slot1Index as preferred slot. secondarySlot(2) is to use the slot referred by c64Slot2Index. The default is primarySlot(1). The slot prefer feature is removed and the the object is deprecated" ::= { c64SlotConfigEntry 5 } c64SlotSwitchOver OBJECT-TYPE SYNTAX INTEGER { ok(1), forceOver(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object, when read always return a value of ok(1). Setting this object to forceOver(2) will have: For a redundant NRP slot pair, force them to exchange the primary and secondary roles. For a redundant carrier slot pair, force both the subslots (line cards) to exchange the primary(working) and secondary(protection) roles." ::= { c64SlotConfigEntry 6 } c64SlotConfigStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "The status object for the c64SlotTable entry." ::= { c64SlotConfigEntry 7 } c64SubSlotConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF C64SubSlotConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of redundant subslot pair entries. A managment station that wish to create the subslot redundancy entry should perform the following steps: Get the ciscoLS1010ModuleIndex & ciscoLS1010SubModuleIndex from ciscoLS1010SubModuleTable which are mapped to the corresponding pair of the physical sub-slots to be configured for the redundancy. Use the pair of the ciscoLS1010ModuleIndex & ciscoLS1010SubModuleIndex and an unique entry index to create table entry. Only the adjacent sub-slots can be configured for redundancy." ::= { c64RedundantGroup 5 } c64SubSlotConfigEntry OBJECT-TYPE SYNTAX C64SubSlotConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry containing information for a particular pair of redundant subslots." INDEX { c64SubSlotConfigModule1Index, c64SubSlotConfigSubModule1Index, c64SubSlotConfigModule2Index, c64SubSlotConfigSubModule2Index, c64SubSlotRedundantIndex } ::= { c64SubSlotConfigTable 1 } C64SubSlotConfigEntry ::= SEQUENCE { c64SubSlotRedundantIndex INTEGER, c64SubSlotConfigModule1Index INTEGER, c64SubSlotConfigSubModule1Index INTEGER, c64SubSlotConfigModule2Index INTEGER, c64SubSlotConfigSubModule2Index INTEGER, c64SubSlot1Name DisplayString, c64SubSlot2Name DisplayString, c64SubSlotConfigPrefIndex INTEGER, c64SubSlotSwitchOver INTEGER, c64SubSlotConfigStatus RowStatus } c64SubSlotRedundantIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS not-accessible STATUS mandatory DESCRIPTION "An arbitrary integer-value to uniquely identify a redundant slot pair. This value must remain constant while the NSP is running. It is not guarenteed to be constant between reboots or switchover of the NSP." ::= { c64SubSlotConfigEntry 1 } c64SubSlotConfigModule1Index OBJECT-TYPE SYNTAX INTEGER(1..15) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the first slot in the pair of sub-slots to be configured for the redundancy. Its value is obtained from the ciscoLS1010ModuleIndex in ciscoLS1010SubModuleTable." ::= { c64SubSlotConfigEntry 2 } c64SubSlotConfigSubModule1Index OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the first sub-slot in the pair of sub-slots to be configured for the redundancy. Its value is obtained from the ciscoLS1010SubModuleIndex in ciscoLS1010SubModuleTable." ::= { c64SubSlotConfigEntry 3 } c64SubSlotConfigModule2Index OBJECT-TYPE SYNTAX INTEGER(1..15) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the second slot in the pair of sub-slots to be configured for the redundancy. Its value is obtained from the ciscoLS1010ModuleIndex in ciscoLS1010SubModuleTable." ::= { c64SubSlotConfigEntry 4 } c64SubSlotConfigSubModule2Index OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the second sub-slot in the pair of sub-slots to be configured for the redundancy. Its value is obtained from the ciscoLS1010SubModuleIndex in ciscoLS1010SubModuleTable." ::= { c64SubSlotConfigEntry 5 } c64SubSlot1Name OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object is to reflect the string name in the format of #/# for the sub-slot1 in the pair of redundancy. This is produced by agent when the table entry is created." ::= { c64SubSlotConfigEntry 6 } c64SubSlot2Name OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object is to reflect the string name in the format of #/# for the sub-slot2 in the pair of redundancy. This is produced by agent when table entry is created." ::= { c64SubSlotConfigEntry 7 } c64SubSlotConfigPrefIndex OBJECT-TYPE SYNTAX INTEGER { primarySubslot(1), secondarySubslot(2) } ACCESS read-write STATUS deprecated DESCRIPTION "This object specify which sub-slot in the pair of redundancy to be used as prefer sub-slot. The value of: primarySubslot(1) is telling the system use the subslot referred by c64SubSlotConfigModule1Index and c64SubSlotConfigSubModule1Index as preferred sub-slot. secondarySubslot(2) is to use the sub-slot referred by c64SubSlotConfigModule2Index and c64SubSlotConfigSubModule2Index. The default is primarySubslot(1). The subslot prefer feature is removed and the object is deprecated" ::= { c64SubSlotConfigEntry 8 } c64SubSlotSwitchOver OBJECT-TYPE SYNTAX INTEGER { ok(1), forceOver(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object, when read always return a value of ok(1). Setting this object to forceOver(2) will have the result of: For a redundant subslot card pair, force the current master and slave cards (for NRPs) or working and protection cards (for linecards) to exchange roles." ::= { c64SubSlotConfigEntry 9 } c64SubSlotConfigStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "The status object for c64SubSlotConfigTable entry. " ::= { c64SubSlotConfigEntry 10 } c64PortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF C64PortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of redundant port-pair entries. A management station that wish to create the redundant entry should perform the following steps: Get the ciscoLS1010ModuleIndex, ciscoLS1010SubModuleIndex and ciscoLS1010PortIndex from ciscoLS1010PortTable which are mapped to the corresponding pair of the physical ports to be configured for the redundancy. Lookup the c64SubSlotConfigTable to see if the corresponding sub-slots has been configured for redundancy. If yes, get the entry's c64SubSlotRedundantIndex. Otherwise the application should abort this port redundancy configuration. Use the c64SubSlotRedundantIndex value and ciscoLS1010ModuleIndex, ciscoLS1010SubModuleIndex and ciscoLS1010PortIndex to create table entry. Only the adjacent ports in the adjacent sub-slots can be configured for redundancy." ::= { c64RedundantGroup 6 } c64PortConfigEntry OBJECT-TYPE SYNTAX C64PortConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry containing information for a particual pair of redundant ports." INDEX { c64PortConfigModule1Index, c64PortConfigSubModule1Index, c64PortConfigPort1Index, c64PortConfigModule2Index, c64PortConfigSubModule2Index, c64PortConfigPort2Index, c64SubSlotRedundantIndex } ::= { c64PortConfigTable 1 } C64PortConfigEntry ::= SEQUENCE { c64PortConfigModule1Index INTEGER, c64PortConfigSubModule1Index INTEGER, c64PortConfigPort1Index INTEGER, c64PortConfigModule2Index INTEGER, c64PortConfigSubModule2Index INTEGER, c64PortConfigPort2Index INTEGER, c64Port1Name DisplayString, c64Port2Name DisplayString, c64PortConfigPrefIndex INTEGER, c64PortSwitchOver INTEGER, c64PortConfigStatus RowStatus } c64PortConfigModule1Index OBJECT-TYPE SYNTAX INTEGER(1..15) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the first slot which contain the port to be configured as the redundancy pair. Its value is obtained from the ciscoLS1010ModuleIndex in ciscoLS1010PortTable." ::= { c64PortConfigEntry 1 } c64PortConfigSubModule1Index OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the first sub-slot which contain the port to be configured as the redundancy pair. Its value is obtained from ciscoLS1010SubModuleIndex in ciscoLS1010PortTable." ::= { c64PortConfigEntry 2 } c64PortConfigPort1Index OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the first port in the pair of ports to be configured for the redundancy. Its value is obtained from ciscoLS1010PortIndex in ciscoLS1010PortTable." ::= { c64PortConfigEntry 3 } c64PortConfigModule2Index OBJECT-TYPE SYNTAX INTEGER(1..15) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the second slot which contain the port to be configured as the redundancy pair. Its value is obtained from the ciscoLS1010ModuleIndex in ciscoLS1010PortTable." ::= { c64PortConfigEntry 4 } c64PortConfigSubModule2Index OBJECT-TYPE SYNTAX INTEGER(0..1) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the second sub-slot which contain the port to be configured as the redundancy pair. Its value is obtained from the ciscoLS1010SubModuleIndex in ciscoLS1010PortTable." ::= { c64PortConfigEntry 5 } c64PortConfigPort2Index OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "This object specify the second port in the pair of ports to be configured for the redundancy. Its value is obtained from the ciscoLS1010PortIndex in ciscoLS1010PortTable." ::= { c64PortConfigEntry 6 } c64Port1Name OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object is to reflect the string name in the format of #/#/# for the port1 in the pair of redundancy. This is produced by agent when the table entry is created." ::= { c64PortConfigEntry 7 } c64Port2Name OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object is to reflect the string name in the format of #/#/# for the port2 in the pair of redundancy. This is produced by agent when the table entry is created." ::= { c64PortConfigEntry 8 } c64PortConfigPrefIndex OBJECT-TYPE SYNTAX INTEGER { primaryPort(1), secondaryPort(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specify which port in the pair of redundancy to be used as prefer port. The value of: primaryPort(1) is telling the system use the port referred by c64PortConfigModule1Index, c64PortConfigSubModule1Index and c64PortConfigPort1Index as preferred port. secondaryPort(2) is to use the port referred by c64PortConfigModule2Index, c64PortConfigSubModule2Index and c64PortConfigPort2Index. The default is primaryPort(1)." ::= { c64PortConfigEntry 9 } c64PortSwitchOver OBJECT-TYPE SYNTAX INTEGER { ok(1), forceOver(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object, when read always return a value of ok(1). Setting this object to one of the acceptable values gives the following results: forceOver(2): Force the current working and protection ports to exchange roles." ::= { c64PortConfigEntry 10 } c64PortConfigStatus OBJECT-TYPE SYNTAX RowStatus -- Rsyntax INTEGER { -- active(1), -- notInService(2), -- notReady(3), -- createAndGo(4), -- createAndWait(5), -- destroy(6) -- } ACCESS read-write STATUS mandatory DESCRIPTION "The status object for c64PortConfigTable entry." ::= { c64PortConfigEntry 11 } c64SonetAPSConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF C64SonetAPSConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing all instances of Sonet APS configuration informations. To configure any APS objects in this table, the corresponding subslots pair have to be already configured for redundancy." ::= { c64RedundantGroup 7 } c64SonetAPSConfigEntry OBJECT-TYPE SYNTAX C64SonetAPSConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry containing APS information for a particular interface." INDEX { ifIndex } ::= { c64SonetAPSConfigTable 1 } C64SonetAPSConfigEntry ::= SEQUENCE { c64SonetAPSMode INTEGER, c64SonetAPSBERThreshold INTEGER, c64SonetAPSSwitchCmd INTEGER, c64SonetAPSSFBERThreshold INTEGER } c64SonetAPSMode OBJECT-TYPE SYNTAX INTEGER { linear(1), yCable(2), disable(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the APS mode on the corresponding interface referenced by ifIndex object. The value linear(1) is the APS mode of linear 1+1 nonreverting and unidirectional. This only true APS mode supported in cisco6400 at FCS. The value yCable(2) is providing the port hardware redundancy but not transmission line redundancy and is not strictly an APS mode." ::= { c64SonetAPSConfigEntry 1 } c64SonetAPSBERThreshold OBJECT-TYPE SYNTAX INTEGER(0..150000) ACCESS read-write STATUS mandatory DESCRIPTION "This is object is used to set the Bit-Error-Rate threshold at which an APS request of priority 'Signal Degrade' will be posted. Value of 0 to disable the threshold." ::= { c64SonetAPSConfigEntry 2 } c64SonetAPSSwitchCmd OBJECT-TYPE SYNTAX INTEGER { lockOut(1), forceWorking(2), forceProtect(3), manualWorking(4), manualProtect(5), clear(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This object when set except clear(4) is used to post an APS priority request. This request succeeds if no higher-priority request is posted. lockOut(1): locks out the protection channel corresponding to this entry forceWorking(2) & manualWorking(4): post a request to switch away from the working channel to protection channel of this entry forceProtect(3) & manualProtect(5): post a request to switch away from the protection channel to working channel of this entry clear(6): Clears all posted APS priority requests in this channel." ::= { c64SonetAPSConfigEntry 3 } c64SonetAPSSFBERThreshold OBJECT-TYPE SYNTAX INTEGER(3..5) ACCESS read-write STATUS mandatory DESCRIPTION "This is object is used to set the Signal Fail Bit-Error-Rate threshold at which an APS request of priority 'Signal Fail' will be posted. 3 => 10E-3, 4 => 10E-4, 5 => 10E-5" ::= { c64SonetAPSConfigEntry 4 } c64SonetAPSStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF C64SonetAPSStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing APS statistics and alarms information for each interface." ::= { c64RedundantGroup 8 } c64SonetAPSStatsEntry OBJECT-TYPE SYNTAX C64SonetAPSStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the c64SonetAPSStatsTable which corresponds to the statistics/alarms kept by a particular APS interface." INDEX { ifIndex } ::= { c64SonetAPSStatsTable 1 } C64SonetAPSStatsEntry ::= SEQUENCE { c64SonetAPSWorkSectionStatus INTEGER, c64SonetAPSWorkLineStatus INTEGER, c64SonetAPSWorkPathStatus INTEGER, c64SonetAPSWorkSectionBIPE Counter, c64SonetAPSWorkLineBIPE Counter, c64SonetAPSWorkLineFEBE Counter, c64SonetAPSWorkPathBIPE Counter, c64SonetAPSWorkPathFEBE Counter, c64SonetAPSWorkPortStatus APSEventStatus, c64SonetAPSProtectSectionStatus INTEGER, c64SonetAPSProtectLineStatus INTEGER, c64SonetAPSProtectPathStatus INTEGER, c64SonetAPSProtectSectionBIPE Counter, c64SonetAPSProtectLineBIPE Counter, c64SonetAPSProtectLineFEBE Counter, c64SonetAPSProtectPathBIPE Counter, c64SonetAPSProtectPathFEBE Counter, c64SonetAPSProtectPortStatus APSEventStatus, c64SonetAPSChannelStatus APSEventStatus } c64SonetAPSWorkSectionStatus OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the section level status of the working channel in APS. The c64SonetAPSWorkSectionStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetSectionNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetSectionNoDefect 2 sonetSectionLOS 3 sonetSectionLOF 4 sonetBIPE(BIp-8)" ::= { c64SonetAPSStatsEntry 1 } c64SonetAPSWorkLineStatus OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the line level status of the working channel in APS. The c64SonetAPSWorkLineStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetLineNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetLineNoDefect 2 sonetLineAIS 3 sonetLineRDI 4 sonetBIPE(BIP-8/24) 5 sonetFEBE" ::= { c64SonetAPSStatsEntry 2 } c64SonetAPSWorkPathStatus OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the path level status of the working channel in APS. The c64SonetAPSWorkPathStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetPathNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetPathNoDefect 2 sonetPathSTSAIS 3 sonetPathSTSRDI 4 sonetPathSTSLOP 5 sonetBIPE(BIP-8) 6 sonetFEBE 7 sonetPathUnequipped 8 sonetPathSignalLabelMismatch" ::= { c64SonetAPSStatsEntry 3 } c64SonetAPSWorkSectionBIPE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of section BIP-8 errors in working channel." ::= { c64SonetAPSStatsEntry 4 } c64SonetAPSWorkLineBIPE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of line BIP-8/24 errors in working channel." ::= { c64SonetAPSStatsEntry 5 } c64SonetAPSWorkLineFEBE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of line far-end-block-errors in working channel." ::= { c64SonetAPSStatsEntry 6 } c64SonetAPSWorkPathBIPE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of path BIP-8 errors in working channel." ::= { c64SonetAPSStatsEntry 7 } c64SonetAPSWorkPathFEBE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of path far-end-block-errors in working channel." ::= { c64SonetAPSStatsEntry 8 } c64SonetAPSWorkPortStatus OBJECT-TYPE SYNTAX APSEventStatus -- Rsyntax INTEGER { -- good(1), -- noHardware(2), -- doNotRevert(3), -- manualSwitch(4), -- signgalDegrade(5), -- forceSwitch(6), -- lockOut(7), -- adminDown(8) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the last aps event detected in working port." ::= { c64SonetAPSStatsEntry 9 } c64SonetAPSProtectSectionStatus OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the section level status of the protection channel in APS. The c64SonetAPSProtectSectionStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetSectionNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetSectionNoDefect 2 sonetSectionLOS 4 sonetSectionLOF 8 sonetBIPE(BIp-8)" ::= { c64SonetAPSStatsEntry 10 } c64SonetAPSProtectLineStatus OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the line level status of the protection channel in APS. The c64SonetAPSProtectLineStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetLineNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetLineNoDefect 2 sonetLineAIS 4 sonetLineRDI 8 sonetBIPE(BIP-8/24) 16 sonetFEBE" ::= { c64SonetAPSStatsEntry 11 } c64SonetAPSProtectPathStatus OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the path level status of the protection channel in APS. The c64SonetAPSProtectPathStatus is a bit map represented as a sum of multiple alarms simultaneously. The sonetPathNoDefect should be set if and only if no other flag is set. The various bit position are: 1 sonetPathNoDefect 2 sonetPathSTSLOP 4 sonetPathSTSAIS 8 sonetBIPE(BIP-8) 16 sonetFEBE 32 sonetPathSTSRDI 64 sonetPathUnequipped 128 sonetPathSignalLabelMismatch" ::= { c64SonetAPSStatsEntry 12 } c64SonetAPSProtectSectionBIPE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of section BIP-8 errors in protection channel." ::= { c64SonetAPSStatsEntry 13 } c64SonetAPSProtectLineBIPE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of line BIP-8/24 errors in protection channel." ::= { c64SonetAPSStatsEntry 14 } c64SonetAPSProtectLineFEBE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of line far-end-block-errors in protection channel." ::= { c64SonetAPSStatsEntry 15 } c64SonetAPSProtectPathBIPE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of path BIP-8 errors in protection channel." ::= { c64SonetAPSStatsEntry 16 } c64SonetAPSProtectPathFEBE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This object counts the number of path far-end-block-errors in protection channel." ::= { c64SonetAPSStatsEntry 17 } c64SonetAPSProtectPortStatus OBJECT-TYPE SYNTAX APSEventStatus -- Rsyntax INTEGER { -- good(1), -- noHardware(2), -- doNotRevert(3), -- manualSwitch(4), -- signgalDegrade(5), -- forceSwitch(6), -- lockOut(7), -- adminDown(8) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the last aps event detected in protection port." ::= { c64SonetAPSStatsEntry 18 } c64SonetAPSChannelStatus OBJECT-TYPE SYNTAX APSEventStatus -- Rsyntax INTEGER { -- good(1), -- noHardware(2), -- doNotRevert(3), -- manualSwitch(4), -- signgalDegrade(5), -- forceSwitch(6), -- lockOut(7), -- adminDown(8) -- } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the last aps event detected in the APS channel." ::= { c64SonetAPSStatsEntry 19 } c64ChassisFacilityAlarmStatus OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object is an OR bit mask indicating the presence of critical/major/minor telco alarm: Bit 0, if set, indicates the presence of minor alarm Bit 1, if set, indicates the presence of major alarm Bit 2, if set, indicates the presence of critical alarm" ::= { c64TelcoAlarmMgmt 1 } c64ChassisClearAlarms OBJECT-TYPE SYNTAX INTEGER { --?? enum value of zero may cause problems -- done(0), all(1), minor(2), major(3), critical(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to clear all, major or minor alarms indication and reset the alarm contacts. When the clear command is done the value of this object will be set to done(0)." ::= { c64TelcoAlarmMgmt 2 } c64ChassisTempIntakeMinorThreshold OBJECT-TYPE SYNTAX INTEGER(20..57) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the intake minor temperature alarm threshold in degrees centigrade. The default value is ???." ::= { c64TelcoAlarmMgmt 3 } c64ChassisTempIntakeMajorThreshold OBJECT-TYPE SYNTAX INTEGER(20..57) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the intake major temperature alarm threshold in degrees centigrade. The default value is ???." ::= { c64TelcoAlarmMgmt 4 } c64ChassisTempCoreMinorThreshold OBJECT-TYPE SYNTAX INTEGER(20..60) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the core minor temperature alarm threshold in degrees centigrade. The default value is ???." ::= { c64TelcoAlarmMgmt 5 } c64ChassisTempCoreMajorThreshold OBJECT-TYPE SYNTAX INTEGER(20..60) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to set the core major temperature alarm threshold in degrees centigrade. The default value is ???." ::= { c64TelcoAlarmMgmt 6 } c64ChassisTempThresholdAdmin OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to enable/disable various threshold limit. Bit 0, if set to 0 disable the intake minor threshold otherwise enable it. Bit 1, if set to 0 disable the intake major threshold otherwise enable it. Bit 2, if set to 0 disable the core minor threshold otherwise enable it. Bit 3, if set to 0 disable the core major threshold otherwise enable it." ::= { c64TelcoAlarmMgmt 7 } c64ChassisAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF C64ChassisAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table contains the current alarm status in the system." ::= { c64ChassisGroup 2 } c64ChassisAlarmEntry OBJECT-TYPE SYNTAX C64ChassisAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry containing alarm information occurred in the system." INDEX { c64ChassisAlarmIndex } ::= { c64ChassisAlarmTable 1 } C64ChassisAlarmEntry ::= SEQUENCE { c64ChassisAlarmIndex INTEGER, c64ChassisAlarmSource DisplayString, c64ChassisAlarmType INTEGER, c64ChassisAlarmSeverity INTEGER, c64ChassisAlarmACOStatus INTEGER } c64ChassisAlarmIndex OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An arbitrary integer value to uniquely identify a alarm information entry." ::= { c64ChassisAlarmEntry 1 } c64ChassisAlarmSource OBJECT-TYPE SYNTAX DisplayString -- Rsyntax OCTET STRING(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the source of alarm. The variable will contain string in the following formats: 'Chassis' indicate the chassis alarms 'Submodule' indicate the submodule alarms 'port@slot#/subslot#/port#' indicate the port alarms. NMS app. will need to recognize the above three format in order to tell the alarm sources. The value other than the above three format cannot be allowed." ::= { c64ChassisAlarmEntry 2 } c64ChassisAlarmSeverity OBJECT-TYPE SYNTAX INTEGER { minor(1), major(2), critical(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the severity of the alarm." ::= { c64ChassisAlarmEntry 4 } c64ChassisAlarmType OBJECT-TYPE SYNTAX INTEGER { coreTemp(1), inletTemp(2), totalFanFail(3), partialFanFail(4), fanMissing(5), pem0Fail(6), pem1Fail(7), sonetLineFail(8), cardOIRAlarm(9), cardFail(10), cardPartialFail(11), linkDownAlarm(12), networkClockAlarm(13), nrpSARFail(14), nrpPAMDataError(15), diskAlarm(16), imageAlarm(17), nrpBootUpAlarm(18), nrpSwitchoverAlarm(19), nrpSecondaryFailureAlarm(20), nrpSecondaryRemovedAlarm(21), nrpMismatchAlarm(22) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the type of alarm." ::= { c64ChassisAlarmEntry 3 } c64ChassisAlarmACOStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), cutoff(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates whether the audible/visible local alarm relay has been locally cut off for this particular alarm source. When this status is 'normal', the alarm in this entry has closed the local audible/visible alarm relay contacts. When this status is 'cutoff', the alarm in this entry initially closed the local relay contacts, but was suppressed by a local user pressing the external ACO button on the 6400 NSP." ::= { c64ChassisAlarmEntry 5 } cisco6400ChassisFailureNotification TRAP-TYPE -- Reverse mappable trap ENTERPRISE cisco6400ChassisMIBNotificationPrefix VARIABLES { c64ChassisFacilityAlarmStatus } -- Status -- mandatory DESCRIPTION "The notification signifies that the agent detects a change in the c64ChassisAlarmTable, the NMS application should start to poll the c64ChassisAlarmTable to get up-to-date alarm information." ::= 1 cisco6400RedundantGroup2 OBJECT IDENTIFIER ::= { cisco6400ChassisMIBGroups 3 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- A collection of objects providing satan redundancy config. -- and information. -- objects -- c64MainCPUConfigAutoSync, c64MainCPUSwitchOver, c64Slot1Name, -- c64Slot2Name, c64SlotSwitchOver, c64SlotConfigStatus, -- c64SubSlot1Name, c64SubSlot2Name, c64SubSlotSwitchOver, -- c64SubSlotConfigStatus, c64Port1Name, c64Port2Name, -- c64PortConfigPrefIndex, c64PortSwitchOver, -- c64PortConfigStatus, c64SonetAPSMode, c64SonetAPSBERThreshold, -- c64SonetAPSSwitchCmd, c64SonetAPSSFBERThreshold, -- c64SonetAPSWorkSectionStatus, c64SonetAPSWorkLineStatus, -- c64SonetAPSWorkPathStatus, c64SonetAPSWorkSectionBIPE, -- c64SonetAPSWorkLineBIPE, c64SonetAPSWorkLineFEBE, -- c64SonetAPSWorkPathBIPE, c64SonetAPSWorkPathFEBE, -- c64SonetAPSWorkPortStatus, c64SonetAPSProtectSectionStatus, -- c64SonetAPSProtectLineStatus, c64SonetAPSProtectPathStatus, -- c64SonetAPSProtectSectionBIPE, c64SonetAPSProtectLineBIPE, -- c64SonetAPSProtectLineFEBE, c64SonetAPSProtectPathBIPE, -- c64SonetAPSProtectPathFEBE, c64SonetAPSProtectPortStatus, -- c64SonetAPSChannelStatus cisco6400ChassisMIBGroup OBJECT IDENTIFIER ::= { cisco6400ChassisMIBGroups 2 } -- OBJECT-GROUP -- Status -- mandatory -- Descr -- A collection of objects providing santa telco alarm -- information. -- objects -- c64ChassisFacilityAlarmStatus, c64ChassisClearAlarms, -- c64ChassisTempIntakeMinorThreshold, -- c64ChassisTempIntakeMajorThreshold, -- c64ChassisTempCoreMinorThreshold, -- c64ChassisTempCoreMajorThreshold, -- c64ChassisTempThresholdAdmin, c64ChassisAlarmIndex, -- c64ChassisAlarmSource, c64ChassisAlarmType, -- c64ChassisAlarmSeverity, c64ChassisAlarmACOStatus cisco6400RedundantGroup OBJECT IDENTIFIER ::= { cisco6400ChassisMIBGroups 1 } -- OBJECT-GROUP -- Status -- deprecated -- Descr -- A collection of objects providing satan redundancy config. -- and information. -- This RFC 2155-level group was deprecated when the -- c64SlotConfigPrefIndex and c64SubSlotConfigPrefIndex -- objects were deprecated. -- objects -- c64MainCPUConfigAutoSync, c64MainCPUSwitchOver, c64Slot1Name, -- c64Slot2Name, c64SlotConfigPrefIndex, c64SlotSwitchOver, -- c64SlotConfigStatus, c64SubSlot1Name, c64SubSlot2Name, -- c64SubSlotConfigPrefIndex, c64SubSlotSwitchOver, -- c64SubSlotConfigStatus, c64Port1Name, c64Port2Name, -- c64PortConfigPrefIndex, c64PortSwitchOver, -- c64PortConfigStatus, c64SonetAPSMode, c64SonetAPSBERThreshold, -- c64SonetAPSSwitchCmd, c64SonetAPSSFBERThreshold, -- c64SonetAPSWorkSectionStatus, c64SonetAPSWorkLineStatus, -- c64SonetAPSWorkPathStatus, c64SonetAPSWorkSectionBIPE, -- c64SonetAPSWorkLineBIPE, c64SonetAPSWorkLineFEBE, -- c64SonetAPSWorkPathBIPE, c64SonetAPSWorkPathFEBE, -- c64SonetAPSWorkPortStatus, c64SonetAPSProtectSectionStatus, -- c64SonetAPSProtectLineStatus, c64SonetAPSProtectPathStatus, -- c64SonetAPSProtectSectionBIPE, c64SonetAPSProtectLineBIPE, -- c64SonetAPSProtectLineFEBE, c64SonetAPSProtectPathBIPE, -- c64SonetAPSProtectPathFEBE, c64SonetAPSProtectPortStatus, -- c64SonetAPSChannelStatus cisco6400ChassisMIBCompliance2 OBJECT IDENTIFIER ::= { cisco6400ChassisMIBCompliances 2 } -- MODULE-COMPLIANCE -- Status -- mandatory -- Descr -- The compliance statement for 6400s, used in Santa NSP, which -- implement the Cisco 6400 Chassis MIB -- Module -- >>current<< -- MandGroup -- cisco6400RedundantGroup2 -- MandGroup -- cisco6400ChassisMIBGroup cisco6400ChassisMIBCompliance OBJECT IDENTIFIER ::= { cisco6400ChassisMIBCompliances 1 } -- MODULE-COMPLIANCE -- Status -- deprecated -- Descr -- The compliance statement for 6400s, used in Santa NSP, which -- implement the Cisco 6400 Chassis MIB. -- -- This compliance statement is deprecated as some objects were -- deprecated in cisco6400RedundantGroup. -- Module -- >>current<< -- MandGroup -- cisco6400RedundantGroup -- MandGroup -- cisco6400ChassisMIBGroup END